1. Produktet er slutview
The Sonew Mini Circuit Breaker Smart Power Meter Switch is a 2-pole DIN rail mount device designed for intelligent electrical system management. It integrates circuit protection with smart metering capabilities, allowing remote control and real-time monitoring via a mobile application. This device provides protection against overcurrent, overload, over-voltage, under-bindtage, and leakage, enhancing electrical safety and efficiency.
2. Sikkerhedsoplysninger
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Always disconnect power at the main circuit breaker before working with electrical wiring.
- Ensure the device is installed in a dry environment, away from moisture and direct sunlight.
- Kontroller, at voltagEnhedens e- og strømstyrkeværdier matcher dine elektriske systemkrav.
- Do not attempt to repair or modify the device. Contact qualified service personnel for assistance.
- Sørg for, at alle ledningsforbindelser er sikre og korrekt isolerede for at forhindre kortslutninger.
3. Specifikationer
| Specifikation | Værdi |
|---|---|
| Mærke | Sonew |
| Nuværende vurdering | 63 Amps |
| Afbryder type | Standard |
| Monteringstype | DIN-skinneophæng |
| Antal polakker | 3 |
| Operation Voltage | 85-300V AC |
| Frekvens | 50/60Hz |
4. Opsætning og installation
This device is designed for DIN rail mounting within an electrical distribution box. Follow these steps for proper installation:
- Strømafbrydelse: Before starting any electrical work, ensure the main power supply to the distribution box is completely disconnected at the source. Use a voltagen tester for at bekræfte, at der ikke er strøm til stede.
- Montering: Attach the circuit breaker onto a standard 35mm DIN rail. The device features a compact design for easy integration into distribution boxes.
- Ledningsføring: Connect the incoming and outgoing wires as indicated on the device. The terminals are typically marked 'N IN', 'L IN' for incoming Neutral and Live, and 'N OUT', 'L OUT' for outgoing Neutral and Live. Refer to the wiring diagram below for correct connections.

Billede: Wiring diagram illustrating the connection points for Neutral (blue) and Live (red) wires on the Sonew Mini Circuit Breaker.

Billede: Side view of the circuit breaker, highlighting the orange clip mechanism for secure DIN rail mounting.

Billede: The compact Sonew Mini Circuit Breaker installed within a typical electrical distribution box, demonstrating its space-saving design and integration with a mobile application.
- Sikre forbindelser: Spænd alle terminalskruer godt fast for at sikre god elektrisk kontakt og forhindre løse forbindelser.
- Strømgendannelse: Når alle forbindelser er sikre og verificerede, skal strømmen til hovedkredsløbet genoprettes.
5. Betjeningsvejledning
5.1 Første opstart og visning
Upon power-up, the device's LCD screen will activate, displaying various electrical parameters. The indicator lights will also show the current status.

Billede: En detaljeret view of the circuit breaker's LCD screen, displaying real-time measurements such as voltage (V), current (A), temperature (°C), and accumulated energy (Kwh).

Billede: The device's display with clear labels for Temperature, Voltage, Current, Electric (energy), and Leakage values, demonstrating how these readings are mirrored and controlled via the connected smartphone application.
5.2 WiFi Network Configuration
To utilize smart features, connect the device to your WiFi network via the Tuya application.
- Download and install the Tuya Smart app on your mobile phone.
- Registrer dig eller log ind på din Tuya-konto.
- Follow the in-app instructions to add a new device. The WiFi indicator on the circuit breaker will blink during network configuration and become steady once successfully connected.

Billede: The device's front panel, highlighting the WiFi indicator light. This light blinks during network setup and remains steady upon successful connection. Other indicators for Voltage, Current, and Leakage are also shown.
5.3 Fjernbetjening og overvågning
Once connected to the Tuya app, you can:
- Fjernbetjening TIL/FRA: Turn the circuit breaker on or off from anywhere using your mobile phone.
- Realtidsdata: Monitor electricity, current, voltage, temperature, and leakage values in real-time.
- Timing kontrol: Set schedules for automatic power on/off for connected devices.
- Stemmestyring: Integrate with compatible voice assistants for hands-free operation.
- Forudbetalt funktion: Utilize the prepaid recharge function available through the app.
6. Beskyttelsesfunktioner
The Sonew Mini Circuit Breaker provides comprehensive protection for your electrical system:
- Overstrømsbeskyttelse: Automatically trips the circuit when the current exceeds the rated limit (63A), preventing damage to appliances and wiring.
- Overbelastningsbeskyttelse: Similar to overcurrent, it protects against sustained excessive current draw.
- Over-voltage Beskyttelse: Disconnects power if the voltage rises above a safe threshold.
- Under-voltage Beskyttelse: Disconnects power if the voltage drops below a safe threshold, protecting sensitive electronics.
- Lækagebeskyttelse: Detects ground fault currents (leakage) and trips the circuit within 0.1 seconds to prevent electrical shock and fire hazards.
These protection thresholds can often be customized within the Tuya application settings.
7. Vedligeholdelse
- Regelmæssig inspektion: Undersøg regelmæssigt enheden for tegn på fysisk skade, løse forbindelser eller misfarvning.
- Rensning: Ensure the device and its terminals are kept clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Funktionstest: If equipped with a test button (not explicitly mentioned for this model, but common for leakage protection), perform periodic tests as recommended by electrical safety standards.
8. Fejlfinding
8.1 Enheden tændes ikke
- Check the main power supply to the distribution box.
- Kontroller, at alle ledningsforbindelser er sikre og korrekte.
- Sørg for, at afbryderen er i 'ON'-positionen.
8.2 Circuit Breaker Trips Frequently
- Overbelastning/Overstrøm: Disconnect some appliances from the circuit to reduce the load. Check for faulty appliances that might be drawing excessive current.
- Lækage: If the leakage indicator is active, there might be a ground fault. Disconnect appliances one by one to identify the faulty device or wiring.
- Voltage-problemer: Tjek den indgående voltage. If it's consistently outside the normal range (85-300V AC), consult an electrician or your power provider.
- Enhedsfejl: If the issue persists after checking external factors, the circuit breaker itself might be faulty.
8.3 Cannot Connect to WiFi/App
- Ensure your WiFi network is 2.4GHz (5GHz networks are typically not supported by smart home devices).
- Check your WiFi password and network stability.
- Ensure the device is within range of your WiFi router.
- Restart the circuit breaker and your router, then attempt to reconfigure the WiFi connection through the Tuya app.
9. Garanti og support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the seller/manufacturer directly. Keep your purchase receipt for warranty claims.