1. Introduktion
This manual provides comprehensive instructions for the installation, operation, and maintenance of the PROFLO PF9312FVPK Dual Flush Valve Assembly. This product is designed for use with PROFLO PF9300 series dual flush tanks, offering an efficient solution for toilet flushing.
2. Sikkerhedsoplysninger
Læs venligst alle instruktioner omhyggeligt inden installation og brug. Manglende overholdelse af disse instruktioner kan resultere i materielle skader eller personskade.
- Always turn off the water supply to the toilet before beginning any installation or maintenance.
- Brug passende personlige værnemidler, såsom handsker og øjenbeskyttelse.
- Hvis du er usikker på nogen del af installationsprocessen, skal du kontakte en kvalificeret VVS-installatør.
- Hold små dele væk fra børn.
3. Pakkens indhold
Kontroller, at alle komponenter er til stede, før installationen påbegyndes:
- PROFLO PF9312FVPK Dual Flush Valve Assembly
- Tripgreb
- Alt nødvendigt hardware til installation

Image 1: The PROFLO PF9312FVPK Dual Flush Valve Assembly with its included trip lever and connecting hose.
4. Opsætning og installation
This dual flush valve assembly is designed for PROFLO PF9300 series dual flush tanks. Ensure your toilet tank is compatible before proceeding.
- Sluk for vandforsyningen: Locate the water supply valve behind the toilet and turn it clockwise until the water flow stops completely. Flush the toilet to empty the tank.
- Remove Old Flush Valve (if applicable): Disconnect the water supply line from the fill valve. Remove the old flush valve by unscrewing the mounting nut from underneath the tank. Clean the tank opening thoroughly.
- Install New Flush Valve: Place the new PROFLO PF9312FVPK Dual Flush Valve Assembly into the tank opening from the inside. Ensure the rubber gasket is properly seated. From underneath the tank, thread the mounting nut onto the flush valve and tighten it securely by hand. Do not overtighten.
- Connect Trip Lever: Attach the included trip lever to the designated connection point on the flush valve. Ensure the chain or cable from the trip lever is connected to the flush valve mechanism, allowing for proper activation of the dual flush feature. Adjust the chain/cable length to ensure both flush options operate correctly without excessive slack or tension.
- Gentilslut vandforsyningen: Reconnect the water supply line to the fill valve. Turn the water supply valve counter-clockwise to restore water flow to the toilet.
- Tjek for lækager: Allow the tank to fill. Inspect all connections for any signs of leaks. If leaks are present, turn off the water supply and re-tighten connections as needed.
5. Betjeningsvejledning
The PROFLO PF9312FVPK Dual Flush Valve Assembly provides two flushing options to conserve water:
- Delvis skylning: For liquid waste, gently press and release the trip lever. This activates a reduced water volume flush.
- Fuld skylning: For solid waste, press and hold the trip lever down for a few seconds. This activates a full water volume flush.
Familiarize yourself with the feel of each flush option to optimize water usage.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your dual flush valve.
- Rensning: Periodically inspect the flush valve for mineral buildup or debris. Turn off the water supply, drain the tank, and gently clean components with a soft brush and mild, non-abrasive cleaner. Avoid harsh chemicals that can damage rubber seals.
- Forseglingsinspektion: Check the rubber seals and gaskets for wear, cracks, or deterioration. Worn seals can lead to leaks and inefficient flushing. Replace any damaged seals promptly.
- Håndtagsjustering: Ensure the trip lever operates smoothly and the chain/cable has the correct tension for both flush options. Adjust if necessary.
7. Fejlfinding
Se følgende tabel for almindelige problemer og løsninger på disse:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Toilettet kører kontinuerligt | Flapper/seal not seating properly; fill valve issue; trip lever chain too tight. | Inspect flush valve seal for debris or wear. Adjust trip lever chain to ensure proper slack. Check fill valve for proper shut-off. |
| Svag rødme | Insufficient water level; partial blockage; flush valve not opening fully. | Adjust fill valve to increase water level. Check for obstructions in the bowl jets. Ensure trip lever chain allows full opening of the flush valve. |
| Toilettet skyller ikke ud | Trip lever disconnected; flush valve mechanism jammed. | Reconnect trip lever chain/cable. Inspect flush valve for any obstructions preventing movement. |
| Leaks from tank base | Løs monteringsmøtrik; beskadiget pakning. | Turn off water, drain tank, and tighten mounting nut. If leak persists, replace the flush valve gasket. |
If the problem persists after attempting these solutions, contact PROFLO customer support or a qualified plumber.
8. Specifikationer
- Model: PF9312FVPK
- Kompatibilitet: PROFLO PF9300 series dual flush tanks
- Varens vægt: 15.4 ounce
- Produktdimensioner: 1 x 1 x 1 inches (Note: These dimensions may refer to packaging or a general placeholder. Actual product dimensions for installation may vary.)
- Fabrikant: Proflo
9. Garanti og support
For warranty information or technical support, please refer to the official PROFLO webwebstedet eller kontakt deres kundeserviceafdeling. Behold din købskvittering som købsbevis.
PROFLO Customer Support: Visit the PROFLO Store on Amazon