1. Introduktion
This manual provides detailed instructions for the installation, operation, and maintenance of the EVURU Digital Single Phase Energy Meter. This device is designed to measure active energy (kWh), voltage, current, and power consumption in single-phase AC circuits. Please read this manual thoroughly before installation and use to ensure safe and correct operation.
2. Sikkerhedsoplysninger
- Installation og vedligeholdelse bør kun udføres af kvalificeret personale.
- Sørg for, at strømforsyningen er afbrudt før installations- eller ledningsføringsarbejde.
- Brug ikke måleren i miljøer med for meget fugt, støv eller ætsende gasser.
- Verify all connections are secure and correct according to the wiring diagrams to prevent damage to the meter or electrical system.
- Måleren er kun beregnet til indendørs brug.
3. Produktet er slutview og funktioner
The EVURU Digital Single Phase Energy Meter is a compact device for DIN rail installation, offering precise measurement of electrical parameters. Key features include:
- LCD display with backlight for clear readings.
- Measures total Energy (kWh), temporary Energy (kWh), real Voltage (V), real Current (A), and real Power (W).
- Pulse LED indicator for active energy measurement.
- 35mm DIN rail mounting.
- Temporary kWh can be reset to zero. Total kWh is non-resettable.

Figur 1: Overview of DDS662, DDS667, and DDS668 models.

Figure 2: Feature comparison table for DDS662, DDS667, and DDS668 models.
4. Specifikationer
| Parameter | Værdi |
|---|---|
| Maksimal strøm | 80A |
| Pulsfrekvens | 1000 imp / kWh |
| Nominel bindtage | 220V AC |
| Installation | 35mm DIN-skinne |
| Display Type | LCD med baggrundsbelysning |
| Målte parametre | Total kWh, Temporary kWh, Voltage, Strøm, Strøm |
| Temporary kWh Reset | Yes (hold button for 6 seconds) |
| Total kWh Reset | Ingen |
| Wiring Modes | Upper input lower output, Lower input upper output |
| Varens vægt | 0.035 ounces (ca. 1 gram) |
5. Installation (Opsætning)
5.1 Dimensioner
Before installation, ensure adequate space for the meter. The dimensions are suitable for standard DIN rail enclosures.

Figure 3: Meter dimensions (example shown for DDS668).
5.2 DIN-skinnemontering
The meter is designed for 35mm DIN rail installation. Simply clip the meter onto the DIN rail in your electrical panel.
5.3 Ledningsdiagrammer
Ensure all power is OFF before proceeding with wiring. Connect the meter according to the appropriate diagram for your model and desired wiring mode.
5.3.1 DDS662 Wiring
The DDS662 model typically uses a direct connection for single-phase two-wire systems.

Figure 4: Wiring diagram for DDS662 model.
5.3.2 DDS667 Wiring
The DDS667 model can be integrated with circuit breakers for protection.

Figure 5: Wiring diagram for DDS667 model, showing integration with circuit breakers.
5.3.3 DDS668 Wiring Modes
The DDS668 model supports two wiring configurations: upper input/lower output and lower input/upper output.

Figure 6: Wiring diagrams for DDS668 model, illustrating upper input/lower output and lower input/upper output modes.
6. Betjening
6.1 Tænd
Once correctly wired and mounted, restore power to the circuit. The LCD display will illuminate, showing the current readings.
6.2 Reading Displayed Values
The meter cycles through various parameters on its LCD display. You can manually press the button (if available on your model, e.g., DDS667, DDS668) to cycle through:
- Samlet energi (kWh)
- Temporary Energy (kWh)
- Rigtig volumentage (V)
- Real Current (A)
- Reel effekt (W)
The pulse LED will flash to indicate active energy measurement.
6.3 Resetting Temporary kWh
To reset the temporary kWh reading to zero, press and hold the button on the front of the meter for approximately 6 seconds. Note that the total kWh reading cannot be reset.
7. Vedligeholdelse
The EVURU Digital Single Phase Energy Meter requires minimal maintenance.
- Hold måleren ren og fri for støv. Brug en blød, tør klud til rengøring.
- Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Kontroller regelmæssigt ledningsforbindelserne for tæthed og tegn på slid eller beskadigelse.
- Ensure the operating environment remains within specified conditions (temperature, humidity).
8. Fejlfinding
- No Display / Meter Not Powering On:
- Check the power supply to the circuit.
- Kontroller, at alle ledningsforbindelser er sikre og korrekte i henhold til diagrammerne.
- Forkerte aflæsninger:
- Ensure the meter is correctly wired for the load. Incorrect wiring can lead to inaccurate measurements.
- Bekræft bindtage and current are within the meter's specified range (e.g., 220V AC, max 80A).
- Temporary kWh Not Resetting:
- Ensure you are holding the reset button for the full 6 seconds.
- Note that the total kWh cannot be reset.
- Puls-LED blinker ikke:
- Verify there is an active load connected and drawing power through the meter.
- Check wiring for proper current flow.
9. Garanti og support
For garantioplysninger eller teknisk support henvises til produktemballagen eller kontakt din forhandler. Gem din købskvittering som købsbevis.