1. Produktet er slutview
The Technoline WT8945 is a radio-controlled wall clock designed for indoor use, offering precise timekeeping along with integrated temperature and humidity displays. Its timeless design with a black frame and white dial ensures clear readability and aesthetic appeal in various indoor environments.

Billede 1.1: Front view of the Technoline WT8945 Radio-Controlled Wall Clock. The clock features a black frame, a white dial with large black numbers, and smaller analog displays for temperature and humidity.
Nøglefunktioner omfatter:
- DCF-77 Radio Control: Ensures automatic and highly accurate time synchronization.
- Analog Temperature Display: Measures indoor temperature from -30 °C to +50 °C.
- Analog Humidity Display: Measures indoor humidity from 0% to 100%.
- Klar læsbarhed: High-contrast white dial with black numbers, visible from a distance.
- Holdbar konstruktion: Robust plastic frame.
- Strømkilde: Operates on 1 x AA Mignon LR06 battery (not included).

Billede 1.2: Visual representation of the clock's main features: temperature display, humidity display, and DCF-77 radio control, shown in a living room setting.
2. Pakkens indhold
Please check the package contents upon unpacking to ensure all items are present and undamaged.
- 1 x Technoline WT8945 Radio-Controlled Wall Clock
- 1 x Brugsanvisning (dette dokument)
3. Opsætning
3.1 Batteriinstallation
The clock requires one AA Mignon LR06 battery (not included) for operation.
- Find batterirummet på bagsiden af uret.
- Åbn batterirummets dæksel.
- Insert one AA Mignon LR06 battery, ensuring the correct polarity (+ and -) as indicated inside the compartment.
- Luk batterirummets dæksel forsvarligt.
Note: Brug altid nye batterier af den anbefalede type. Bland ikke gamle og nye batterier eller forskellige typer batterier.
3.2 Indledende tidssynkronisering
After battery installation, the clock will automatically attempt to synchronize with the DCF-77 radio signal. This process may take several minutes to a few hours, depending on your location and signal strength.
- The clock hands will typically move to the 12 o'clock position and then begin searching for the signal.
- Når signalet modtages, indstiller uret sig automatisk til det korrekte tidspunkt.
- For den bedste modtagelse skal uret placeres i nærheden af et vindue og væk fra elektroniske enheder, der kan forårsage interferens.
3.3 Placering
Choose a suitable indoor location for your wall clock. Consider the following:
- Sigtbarhed: Ensure the clock is easily visible from your desired viewing område.
- Signalmodtagelse: For optimal radio signal reception, avoid placing the clock near large metal objects, concrete walls, or other electronic devices that might interfere with the signal.
- Miljøforhold: While the clock displays temperature and humidity, avoid placing it in direct sunlight, near heat sources, or in areas with extreme temperature fluctuations or high humidity, as this may affect the accuracy of the sensors.
4. Betjeningsvejledning
4.1 Aflæsning af tiden
The Technoline WT8945 displays time using traditional analog clock hands (hour, minute, second). The radio-controlled mechanism ensures the time is always accurate to the DCF-77 signal.
4.2 Aflæsning af temperatur og luftfugtighed
The clock features two smaller analog dials on its face:
- Temperaturvisning: Located on the left side of the dial, it shows the indoor temperature in degrees Celsius (°C). The measurement range is from -30 °C to +50 °C.
- Fugtighedsdisplay: Located on the right side of the dial, it shows the indoor relative humidity as a percentage (%). The measurement range is from 0% to 100%.
These displays provide a quick overview of your indoor climate conditions.
4.3 Manual Time Adjustment (If Radio Signal is Unavailable)
In areas where the DCF-77 radio signal is weak or unavailable, the clock can be manually set. This feature is particularly useful if the clock fails to synchronize automatically.
- Fjern batteriet fra uret.
- Wait for approximately 1 minute.
- Reinsert the battery. The clock hands will move to the 12 o'clock position.
- Immediately after the hands reach 12, a small adjustment wheel or button should be accessible on the back of the clock (often near the battery compartment). Use this to manually set the time.
- Once the desired time is set, the clock will operate as a standard quartz clock until a DCF-77 signal is successfully received, at which point it will automatically re-synchronize.
Note: The exact method for manual adjustment may vary slightly. Refer to any specific markings or controls on the back of your clock if the above steps do not immediately apply.
5. Vedligeholdelse
Proper maintenance ensures the longevity and accurate operation of your Technoline WT8945 wall clock.
- Rensning: Wipe the clock's surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or chemical agents, as these may damage the plastic frame or dial.
- Udskiftning af batteri: Replace the AA battery annually, or when the clock hands stop moving or become erratic. Remove depleted batteries promptly to prevent leakage and damage to the clock mechanism.
- Miljøbeskyttelse: Protect the clock from extreme temperatures, direct sunlight, and high humidity.
6. Fejlfinding
If you encounter issues with your Technoline WT8945 clock, refer to the following troubleshooting guide:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Clock hands do not move or stop. | Afladet batteri. | Udskift AA-batteriet med et nyt. |
| Uret synkroniserer ikke eller viser forkert tid. | Weak or no DCF-77 radio signal. Interference from other electronics. Incorrect initial setup. |
|
| Temperature or humidity display is inaccurate or stuck. | Sensor obstruction. Extreme environmental conditions. |
|
7. Specifikationer

Billede 7.1: Dimensions of the Technoline WT8945 Wall Clock, showing a 30 cm diameter.
| Feature | Detalje |
|---|---|
| Mærke | Technoline |
| Modelnummer | WT8945 |
| Farve | Sort |
| Produktmål (L x B x H) | 30 x 3.81 x 30 cm |
| Varens vægt | 730 gram |
| Materiale | Plast |
| Display Type | Analog |
| Særlige funktioner | Humidity Display, Radio-Controlled Time (DCF-77) |
| Temperaturmåleområde | -30 °C til +50 °C |
| Fugtmåleområde | 0 % til 100 % |
| Strømkilde | 1 x AA Mignon LR06 Battery (not included) |
| Indendørs/Udendørs brug | Indendørs |
| Form | Rund |
8. Garanti og support
Technoline products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your purchase or contact your retailer. For technical support or further assistance, please visit the official Technoline webwebsted eller kontakt deres kundeserviceafdeling.
Gem venligst din købsbevis i tilfælde af garantikrav.