Opengear CM8116

Opengear CM8100 Console Server User Manual

Model: CM8116

Indledning

This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outages.

Key features of the CM8100 Console Server include:

  • 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
  • Support for Data Center and Enterprise Network automation with Python and Docker.
  • Embedded physical security via TPM 2.0 module.
  • Dual power supplies for redundancy and independent monitoring.
  • Integrated environmental temperature monitoring.

Opsætning og installation

This section guides you through the physical installation and initial setup of your CM8100 Console Server.

Udpakning af enheden

Pak forsigtigt alle komponenter ud af kassen. Kontroller, at alle de dele, der er anført i afsnittet "Hvad er der i kassen", er til stede og ubeskadigede.

Opengear CM8100 Console Server front view

Billede: Forside view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.

Rackmontering

The CM8100 Console Server is designed for standard 19-inch rack installation.

  1. Attach the two rack ears to the sides of the console server using the provided M4 screws.
  2. Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.

Strømtilslutning

The CM8100 features dual power supplies for redundancy.

  1. Connect the two A/C power cables to the power inlets on the rear of the console server.
  2. Connect the other ends of the power cables to independent power sources for redundancy.
  3. Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.

Netværksforbindelse

Connect the console server to your network for management access.

  1. Connect an Ethernet cable from your network switch to the primary network port on the console server.
  2. (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.

Seriel portforbindelse

Connect your managed devices (servers, network devices) to the serial ports on the CM8100.

  1. Identify the serial ports on the rear of the console server.
  2. Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
  3. Note the port numbers for future configuration.
Bag view of Opengear CM8100 Console Server showing network and serial ports

Billede: Bagside view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.

Operation

This section covers basic operation and initial access to the CM8100 Console Server.

Indledende adgang

Access the console server for initial configuration via a direct serial connection or network connection.

Serial Console Access

  1. Connect a computer to the console server's dedicated console port using a serial cable.
  2. Konfigurer din terminalemuleringssoftware (f.eks. PuTTY, Tera Term) med følgende indstillinger: 115200 baud, 8 databits, ingen paritet, 1 stopbit, ingen flowkontrol.
  3. Power on the CM8100. The boot process will display on your terminal.
  4. Log in using the default credentials (refer to the Quick Start Guide for default username and password).

Network Access (Web grænseflade)

Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web interface.

  1. Åbn a web browser and enter the IP address of the CM8100.
  2. Log ind med dine legitimationsoplysninger.
  3. Fra web interface, you can configure serial ports, network settings, user accounts, and other system parameters.

Håndtering af tilsluttede enheder

The CM8100 allows you to connect to the console of your attached devices.

  • Serial Console Access: Fra web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
  • Out-of-Band Management: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.

Opretholdelse

Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.

Firmware opdateringer

Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.

  1. Download the latest firmware image from the official Opengear support portal.
  2. Access the CM8100 web interface.
  3. Navigate to the firmware update section (typically under System > Firmware).
  4. Follow the on-screen instructions to upload and install the new firmware. Do not power off the device during the update process.

Rensning

Keep the console server clean to prevent dust buildup, which can affect cooling.

  • Brug en blød, tør klud til at aftørre enhedens ydre.
  • Sørg for, at ventilationsåbningerne er fri for forhindringer.
  • Brug ikke flydende rengøringsmidler direkte på enheden.

Miljøhensyn

Ensure the operating environment meets the recommended conditions.

  • Maintain proper airflow around the device.
  • Keep the device within specified temperature and humidity ranges.

Fejlfinding

This section provides solutions to common issues you might encounter with the CM8100 Console Server.

Ingen strøm

  • Symptom: Power indicator LEDs are off, device does not respond.
  • Løsning: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.

Kan ikke få adgang Web Interface

  • Symptom: Web browser cannot connect to the CM8100 IP address.
  • Løsning:
    1. Verify the console server has power and is running.
    2. Confirm the network cable is properly connected to an active network port.
    3. Check the IP address configuration of the CM8100 (via serial console if necessary).
    4. Ensure your computer is on the same network or has a route to the CM8100's IP address.
    5. Deaktiver midlertidigt alle firewalls på din computer for at udelukke interferens.

No Serial Console Connection to Managed Device

  • Symptom: Unable to establish a serial connection to a device connected to the CM8100.
  • Løsning:
    1. Verify the serial cable connection between the CM8100 port and the managed device.
    2. Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
    3. Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
    4. Confirm the managed device is powered on and functioning correctly.

Specifikationer

Feature Detalje
Mærke Opengear
Serie CM8100 Console Server
Modelnummer CM8116
Varens vægt 8.63 pund
Produktmål (LxBxH) 19.5 x 16.5 x 3.5 tommer
Fabrikant Opengear
Først tilgængelig 16. februar 2023

Hvad er der i æsken

The following items are included with your Opengear CM8100 Console Server:

  • CM8100 Console Server
  • Rack Mount Kit
  • 2 x Rack Ears with Six M4 Screws
  • 4 x M5mm Caged Nuts
  • 4 x M5x15mm Rack Screws
  • 1 x CAT5 Patch Cable 6'
  • 1 x DB9F-RJ45 Rollover Serial Adapter
  • 2 x A/C Power Cables
  • Hurtig startvejledning
  • Lighthouse Insert