1. Introduktion
This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 1000 AT FR Online Uninterruptible Power Supply (UPS). The VFI AT series utilizes double-conversion technology to provide reliable power protection for critical devices. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Sikkerhedsinstruktioner
WARNING: Failure to follow these safety instructions can result in fire, electric shock, serious injury, or death.
- Åbn ikke UPS'en casing. Der er ingen dele indeni, som brugeren kan servicere. Overlad al service til kvalificeret servicepersonale.
- Do not connect appliances that could overload the UPS, such as hair dryers or vacuum cleaners.
- Ensure the UPS is connected to a properly grounded power outlet.
- Do not block ventilation openings. Maintain adequate clearance around the UPS for proper airflow.
- Undgå at installere UPS'en i områder med meget støv, fugtighed eller ekstreme temperaturer.
- In case of emergency, press the OFF button and disconnect the UPS from the AC power source.
3. Produktet er slutview
The PowerWalker VFI 1000 AT FR UPS is designed to provide clean, stable power to your connected equipment. It features a user-friendly interface and various connectivity options.
3.1 Frontpanel

Figure 3.1: Front Panel of the UPS. This image shows the main display screen indicating input and output voltage, battery status, and load level. Below the screen are four control buttons: ON, OFF, ENTER, and ESC.
The front panel includes an LCD display that provides real-time information about the UPS status, such as input/output voltage, battery charge, and load level. Control buttons allow for easy navigation and configuration.
- LCD-skærm: Shows operational status and parameters.
- ON knap: Powers on the UPS.
- OFF knap: Slukker for UPS'en.
- ENTER knap: Bekræfter valg eller åbner menuer.
- ESC knap: Afslutter menuer eller annullerer handlinger.
3.2 Bagpanel

Figure 3.2: Rear Panel of the UPS. This image displays the connectivity options including a serial port (DB9), cooling fan, multiple Type F outlets, a USB port, an EPO (Emergency Power Off) terminal, and the AC input socket.
The rear panel provides all necessary connections for input power, output to protected devices, and communication interfaces.
- AC-indgang: Tilslutter UPS'en til hovedstrømforsyningen.
- Udgangsstik: Type F, Type E, or Type G outlets (depending on model) for connecting protected equipment.
- USB-port: For communication with a computer and monitoring software.
- RS-232 Port (Serial): For advanced communication and monitoring.
- EPO (nødslukning) terminal: Til fjernbetjent nødafbrydelse.
- Intelligent slot: Til valgfrie kommunikationskort (f.eks. SNMP-kort).
- Ekstern batteripakke: For connecting optional external battery packs to extend backup time.
4. Opsætning
4.1 Udpakning og inspektion
Carefully unpack the UPS and inspect it for any shipping damage. If any damage is found, do not install the unit and contact your dealer.
4.2 Placering
Place the UPS in a clean, dry, and well-ventilated area. Ensure sufficient clearance (at least 20 cm) around the unit for proper heat dissipation. Avoid direct sunlight, heat sources, and excessive moisture.
4.3 Indledende opladning
Before initial use, connect the UPS to a standard AC power outlet for at least 8 hours to ensure the internal batteries are fully charged. The UPS will charge its batteries whether it is turned ON or OFF.
4.4 Tilslutning af udstyr
- Connect your critical equipment (computers, monitors, network devices) to the output sockets on the rear panel of the UPS.
- Connect the UPS power cord to a grounded AC power outlet.
- (Optional) Connect the USB or RS-232 cable from the UPS to your computer for monitoring and management.
- (Optional) If using external battery packs, connect them according to their specific instructions to the designated connector on the UPS.
5. Betjening af UPS'en
5.1 Tænd UPS'en
Tryk og hold på ON button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates. The UPS will perform a self-test and then enter normal operating mode.
5.2 Slukning af UPS'en
To turn off the UPS, press and hold the SLUKKET button for approximately 2 seconds until the LCD display turns off. Ensure all connected equipment is properly shut down before turning off the UPS.
5.3 LCD-skærm og navigation
The LCD display provides various operational parameters. Use the ENTER og ESC buttons to navigate through menus and view different information screens. The display automatically darkens after a period of inactivity and can be woken up with a single button press.
5.4 Remote Shutdown (RPO)
The UPS supports Remote Power Off (RPO) functionality. Connect an external switch to the EPO terminal on the rear panel. Activating this switch will immediately shut down the UPS and connected equipment. Refer to the wiring diagram in the advanced user manual for proper connection.
6. Vedligeholdelse
6.1 Pleje af batterier
The UPS contains internal lithium batteries. To maximize battery life:
- Keep the UPS connected to AC power to keep batteries charged.
- Undgå at opbevare UPS'en i ekstreme temperaturer.
- Perform a battery calibration (if available via software) or a full discharge/recharge cycle every 3-6 months.
- Replace batteries when their capacity significantly degrades. Battery replacement should only be performed by qualified personnel.
6.2 Rengøring
Rengør UPS'ens yderside med en blød, tør klud. Brug ikke flydende rengøringsmidler eller rengøringsmidler på aerosolbasis. Sørg for, at ventilationsåbningerne er fri for støv og snavs.
6.3 Opbevaring
If storing the UPS for an extended period, ensure the batteries are fully charged. Recharge the batteries every three months to prevent permanent damage.
7. Fejlfinding
This section provides solutions to common issues you may encounter with your UPS. If the problem persists, contact technical support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| UPS'en tænder ikke. | No AC input power; Low battery charge. | Check AC power connection; Allow UPS to charge for 8 hours. |
| UPS'en bipper kontinuerligt. | Overload; Low battery; Fault condition. | Reduce connected load; Allow batteries to charge; Check LCD for error codes. |
| Kort backuptid. | Batterierne er ikke fuldt opladede; Batterierne er ved at være udtjente. | Ensure full charge; Consider battery replacement. |
| Tilsluttet udstyr modtager ikke strøm. | UPS is off; Output sockets not enabled; UPS in fault mode. | Turn on UPS; Check LCD for status; Consult manual for output settings. |
8. Specifikationer
| Feature | Detalje |
|---|---|
| Model | VFI 1000 AT FR (Model Number: 10122183) |
| Mærke | PowerWalker |
| Udgangseffektkapacitet | 900W |
| Input bindtage | 220V (Wide input voltage rækkevidde) |
| Batteritype | Lithium |
| Udgangsstik | Type F, Type E, Type G (various versions available) |
| Kommunikationsporte | USB (HID support), RS-232, Intelligent Slot |
| Dimensioner (H x B x D) | 50 x 10 x 48 cm (omtrentligt) |
| Vægt | 2 kilo |
| Særlige funktioner | Double-conversion online technology, Generator compatible, RPO, External battery pack support, Automatically darkening LCD. |
9. Garanti og support
The PowerWalker VFI 1000 AT FR UPS is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official PowerWalker webhjemmeside for detaljerede garantivilkår.
For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact your local dealer or PowerWalker customer service. The EU Spare Part Availability Duration is 2 Years.