OWON OW18E

OWON OW18E Digital Multimeter User Manual

Model: OW18E | Brand: OWON

1. Introduktion

The OWON OW18E is a high-precision 4½ digit digital multimeter designed for accurate electrical measurements. With a 20,000-count display and True RMS capability, it provides reliable readings for various waveforms. This device integrates Bluetooth 4.0 for wireless data transfer and logging, enhancing efficiency in diverse applications such as research, manufacturing, and maintenance. Its robust design, safety features, and user-friendly functions make it an essential tool for professionals and enthusiasts.

OWON OW18E Multimeter with key features highlighted

Image 1.1: OWON OW18E Multimeter highlighting its 4½ digit, 20000 counts, True RMS, Bluetooth, Data-logging, AC/DC Current, Diode Test, Capacitance, Temperature, Frequency, Continuity Buzzer, AC/DC Voltage, and Non-Contact Voltage Detect features.

2. Sikkerhedsoplysninger

Always adhere to safety precautions when using the OWON OW18E Digital Multimeter to prevent electric shock or damage to the device. This multimeter is designed to meet safety standards, but improper use can still lead to hazards.

  • Overskrid ikke de maksimale inputgrænser for any measurement range.
  • Ensure test leads are properly connected and in good condition before making measurements.
  • Avoid touching exposed conductors or circuit components while power is applied.
  • Brug den kontaktfri volumentage (NCV)-funktion to detect live wires before making contact.
  • Udskift batterierne med det samme when the low battery indicator appears to ensure accurate readings and proper operation.
  • Do not operate the multimeter if it appears damaged or if the case is open.
  • Refer to the complete safety guidelines in the detailed user manual available on the OWON official webwebsted.

3. Produktet er slutview og komponenter

Familiarize yourself with the main components of your OWON OW18E Digital Multimeter.

Front view of OWON OW18E Multimeter with labeled parts

Billede 3.1: Forside view of the OWON OW18E Multimeter, showing the LCD display, Rotary Switch, Bluetooth/Backlight Buttons, Non-Contact Voltage Detect area, Flashlight, 20A current input terminal, mA µA input terminal, V/Ω/Hz/(t)/°C input terminal, and COM input terminal.

Tilbage view of OWON OW18E Multimeter with labeled parts and accessories

Billede 3.2: Bagside view of the OWON OW18E Multimeter, illustrating the Insulated non-slip case, Test Lead Slot, Retractable Stand, Fuse and 1.5V battery compartment. Insets show the high definition backlit LCD, rotary switch with accurate scale, smooth and fastened sockets, Non-Contact Voltage Detect area, protective sleeve, and storage slot for test leads.

4. Opsætning

Før du bruger dit multimeter, skal du sørge for, at det er korrekt indstillet.

4.1 Batteriinstallation

  1. Sørg for, at multimeteret er slukket.
  2. Locate the battery compartment on the back of the device (refer to Image 3.2).
  3. Brug en skruetrækker til at åbne batteridækslet.
  4. Insert the required 1.5V batteries (or 9V battery if applicable, as shown in Image 8.1) according to the polarity markings.
  5. Luk batteridækslet forsvarligt.

4.2 Tilslutning af testledning

  1. Connect the black test lead to the 'COM' input terminal.
  2. Connect the red test lead to the appropriate input terminal based on the measurement function:
    • For bindtage, Resistance, Capacitance, Frequency, Diode, Continuity, and Temperature measurements, connect the red lead to the 'V/Ω/Hz/(t)/°C' terminal.
    • For mA or µA current measurements, connect the red lead to the 'mA µA' terminal.
    • For 20A current measurements, connect the red lead to the '20A' terminal.
  3. Sørg for, at alle forbindelser er faste og sikre.

5. Betjeningsvejledning

This section details how to perform various measurements and utilize the multimeter's functions.

5.1 Grundlæggende målinger

  1. Voltage (AC/DC) Measurement:
    Drej drejekontakten til 'V~' (AC-volumen)tage) eller 'V-' (DC-volumentage) position. Connect the test leads in parallel to the circuit or component to be measured. The reading will appear on the LCD.
  2. Current (AC/DC) Measurement:
    Turn the rotary switch to the 'A~' (AC Current) or 'A-' (DC Current) position, selecting the appropriate range (µA, mA, or 20A). Connect the test leads in series with the circuit.
  3. Modstandsmåling:
    Turn the rotary switch to the 'Ω' position. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance.
  4. Kapacitansmåling:
    Turn the rotary switch to the 'F' (Capacitance) position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.
  5. Temperaturmåling:
    Turn the rotary switch to the '°C/°F' position. Connect the K-type thermocouple (included) to the input terminals. The temperature will be displayed.
  6. Frequency (Hz) Measurement:
    Turn the rotary switch to the 'Hz' position. Connect the test leads to the signal source.
  7. Diode test:
    Turn the rotary switch to the 'Diode' symbol position. Connect the red lead to the anode and the black lead to the cathode of the diode. The forward voltage drop vil blive vist.
  8. Kontinuitetstest:
    Turn the rotary switch to the 'Continuity' symbol position. Connect the test leads across the circuit or component. A buzzer will sound if continuity is detected.

5.2 Specialfunktioner

  • Ægte RMS: The OW18E features True RMS measurement, providing accurate readings for both sinusoidal and non-sinusoidal AC waveforms.
  • Non-Contact Voltage (NCV) Detektion: Activate the NCV function to detect the presence of AC voltage without direct contact. The strength indicator will illuminate, and an audible alarm will sound if voltage er opdaget.
  • Baggrundsbelysning: Press the backlight button to illuminate the LCD for improved visibility in low-light conditions.
  • Data Hold: Tryk på 'HOLD'-knappen for at fryse den aktuelle aflæsning på displayet. Tryk igen for at slippe.
  • Relativ værdimåling: This function allows you to measure the difference between a current reading and a stored reference value.
  • Lommelygte: The built-in flashlight can be activated to illuminate the work area.
Multimeter demonstrating NCV, temperature, and flashlight functions, and calibration

Image 5.1: The OWON OW18E demonstrating Non-Contact Voltage Detect, Temperature Measurement with non-contact thermocouple, and the built-in Flashlight. Also shown are calibration tests for standard voltage, resistance, and current measurements.

5.3 Bluetooth Connectivity and Data Logging

The OW18E supports Bluetooth 4.0 for wireless communication with smartphones or PCs, enabling real-time data transfer and logging.

Bluetooth function showing real-time data transfer to smartphone and PC

Image 5.2: Bluetooth function introduction, showing voice broadcast measurement support and stable Bluetooth 4.0 transmission for real-time display on mobile phones and PCs. A Bluetooth USB dongle (optional) may be required for PC connection.

Multimeter app interface for data logging and analysis

Image 5.3: The OWON OW18E functioning as a data-logger, with its app interface displaying logged values in charts and tables. The record interval can be adjusted (default >0.5s). The image also illustrates simultaneous measurement of multiple data sets for analysis and comparison.

5.3.1 Offline Recording Function

App interface for setting and downloading offline recorded data

Image 5.4: The app interface for the offline recording function. It shows how to set the sample interval (1 to 4,200,000 seconds) and the number of recording points (0 to 10,000 points). After recording, the data is saved in the multimeter's internal memory and can be downloaded to the mobile app for analysis. If the battery is low, the meter will shut down for data protection before the data is downloaded.

For detailed instructions on using the Bluetooth app, please refer to the App Installation Guide included with your product or download the full user manual from the OWON official webwebsted: http://www.owon.com.hk/bluetooth4

6. Vedligeholdelse

Korrekt vedligeholdelse sikrer multimeterets levetid og nøjagtighed.

  • Rensning: Brug en blød, damp cloth to clean the exterior of the multimeter. Do not use abrasive cleaners or solvents.
  • Udskiftning af batteri: Replace batteries as soon as the low battery indicator appears to prevent inaccurate readings or device shutdown during critical measurements. Refer to Section 4.1 for battery installation.
  • Udskiftning af sikring: If the current measurement function fails, the fuse may need replacement. Refer to the detailed manual for instructions on accessing and replacing the fuse. Always use a fuse of the specified type and rating.
  • Opbevaring: When not in use for extended periods, remove the batteries and store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures.

7. Fejlfinding

If you encounter issues with your OWON OW18E, try the following troubleshooting steps:

ProblemMulig årsagLøsning
No display or weak displayLow battery or no battery installedReplace or install new batteries.
Forkerte aflæsningerIncorrect range selected, poor test lead connection, or damaged test leadsEnsure correct range, check test lead connections, or replace test leads.
Strømmåling virker ikkeSprunget sikringUdskift sikringen med den angivne type og mærkeværdi.
Problemer med Bluetooth-forbindelseBluetooth not enabled, app not installed, or device out of rangeEnsure Bluetooth is on, install the OWON app, and keep devices within range. For PC, ensure a Bluetooth dongle is used.

Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte OWONs kundesupport.

8. Specifikationer

The OWON OW18E Digital Multimeter offers the following technical specifications:

FeatureSpecifikation
Visningstælling20,000 counts (4½ digits)
Ægte RMSJa
BluetoothBluetooth 4.0
DatalogningUp to 10,000 points (offline recording)
AC/DC VoltageMeasurement capability included
AC / DC strømMeasurement capability included (up to 20A)
ModstandMeasurement capability included
KapacitansMeasurement capability included
TemperaturMeasurement capability included (K-type thermocouple)
FrekvensMeasurement capability included
DiodetestJa
Kontinuitet BuzzerJa
Non-Contact Voltage (NCV)Ja
BaggrundsbelysningJa
LommelygteJa
StrømkildeAC (implied by product description, typically battery-powered for handheld)
Produktmål (L x B x H)196 mm x 88.5 mm x 56 mm
Produktets nettovægt0.32 kg
Inkluderet tilbehørMultimeter leads, K-type thermocouple, screwdriver, alligator clips, instructions, app installation guide
OWON OW18E Multimeter package contents and dimensions

Image 8.1: Product contents and dimensions. Includes the OW18E multimeter, 9V battery (optional), screwdriver, K-type thermocouple, alligator clips, multimeter leads, instructions, and app installation guide. Product dimensions are 196mm x 88.5mm x 56mm, with a net weight of 0.32 kg.

9. Garanti og support

OWON is committed to providing high-quality products and reliable customer support.

9.1 Garantioplysninger

OWON products purchased through Amazon are covered by a standard warranty:

  • Hovedenhed: 3 års producentgaranti.
  • Tilbehør: 1-year warranty for modules, probes, and batteries.

9.2 Kundesupport

For any inquiries, technical assistance, calibration services, repair requests, or other support needs, please contact OWON directly.

  • Officiel Webwebsted: User manuals and additional resources can be downloaded from the OWON official webwebsted: owon.co.jp
  • Kontakt for service: For calibration, repair, or other service requests, please visit the OWON official website and use the contact form or provided contact information. When requesting repair, please provide your purchase route, purchase date, and model name.
  • Bulk Purchases/Demo Units: For corporate customers interested in bulk purchases or borrowing demo units, please contact OWON via their official webwebsted.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.