1. Introduktion
This manual provides instructions for the safe and effective use of the YESWELDER QB02 Welding Gas Regulator Flow Meter with Gas Hose. This integrated unit combines a regulator and flow meter, designed for precise gas flow control in MIG/TIG welding, chemical processing, and general industrial applications. It is compatible with Argon, Helium, and Argon/CO₂ mixed gas tanks.
2. Sikkerhedsoplysninger
Always prioritize safety when working with compressed gases and welding equipment. Failure to follow safety guidelines can result in serious injury or property damage.
- Ensure the gas cylinder is securely fastened to prevent tipping.
- Always open the cylinder valve slowly to prevent sudden pressure surges.
- Never use oil or grease on regulator connections, as this can cause an explosion with oxygen.
- Check all connections for leaks using a leak detection solution (e.g., soapy water) before operation.
- Brug passende personlige værnemidler (PPE), herunder sikkerhedsbriller og handsker.
- Do not attempt to repair or modify the regulator. Contact qualified personnel for service.
- Sørg for tilstrækkelig ventilation i arbejdsområdet.
3. Pakkens indhold
Bekræft at alle varer er til stede i pakken:
- 1 x YESWELDER QB02 Argon Regulator Flow Meter
- 1 x 8.2ft Gas Hose
- 1 x Slange Clamp
- 1 x Mounting Nut
4. Specifikationer
| Modelnummer | QB02 |
| Indløbsforbindelse | CGA-580 (.960"-14 RH Male) |
| Trykmålerområde | 0-4000 PSI |
| Flowhastighedsområde | 0-60 CFH (Cubic Feet per Hour) |
| Output Connection Options | Female 9/16" x 18 nut, Male 5/8" x 18 fitting, 1/4" barbed fitting |
| Slange længde | 8.2 fod |
| Materiale | Copper construction |
| Varens vægt | 2.25 pund |
5. Opsætningsvejledning
5.1 Connecting the Regulator to the Gas Tank
- Sørg for, at gasflaskens ventil er lukket.
- Inspect the CGA-580 inlet nut on the regulator and the cylinder valve for any debris or damage.
- Thread the CGA-580 inlet nut of the regulator onto the gas cylinder valve. Hand-tighten first, then use a wrench to secure it firmly. Do not overtighten.
- Once connected, slowly open the gas cylinder valve. The pressure gauge on the regulator should indicate the cylinder pressure.

Billede: Detaljeret view of the regulator's connection points, including the CGA-580 inlet and various output fittings.
5.2 Connecting the Gas Hose
The regulator offers three connection methods for the gas hose:
- 1/4" Barbed Fitting: For direct connection to a 1/4" hose. Secure with the provided hose clamp.
- Female 9/16" x 18 Nut: For hoses with a male 9/16" x 18 fitting.
- Male 5/8" x 18 Fitting: For hoses with a female 5/8" x 18 nut.
Select the appropriate connection method for your welding equipment and securely attach the 8.2ft gas hose. Ensure all connections are tight to prevent leaks.

Image: Visual guide to the three flexible connection methods for the gas hose.
Video: An official YESWELDER video demonstrating the installation and use of the gas regulator.
6. Betjeningsvejledning
6.1 Adjusting Gas Flow Rate
- After connecting the regulator and hose, ensure the gas cylinder valve is open.
- Locate the flow adjustment knob on the regulator.
- Slowly turn the adjustment knob to increase or decrease the gas flow. The floating ball in the square flow tube will indicate the current flow rate in CFH (Cubic Feet per Hour).
- Adjust the flow rate according to your welding process requirements.

Image: The precise measurement gauges and flow tube for accurate gas control.
6.2 Reading the Pressure Gauge
The large 1 1/2-inch diameter pressure gauge displays the cylinder pressure, with a measuring range of 0-4000 PSI. This allows for easy monitoring of the remaining gas supply.
7. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your gas regulator.
- Lækagekontrol: Periodically check all connections for leaks using a soapy water solution. Bubbles indicate a leak. Tighten connections or replace seals as necessary.
- Rensning: Keep the regulator clean and free from dust, dirt, and oil. Use a soft, dry cloth for cleaning. Do not use harsh chemicals.
- Opbevaring: When not in use, store the regulator in a clean, dry environment, disconnected from the gas cylinder.
- Filterinspektion: The regulator features a full copper high-density macromolecule filter to remove impurities. While designed for efficiency, periodic inspection for excessive buildup is recommended.

Image: The internal high-density macromolecule filter for gas purification.
8. Fejlfinding
If you encounter issues with your gas regulator, refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| No gas flow or low flow | Cylinder valve closed; low cylinder pressure; clogged filter; flow adjustment knob closed. | Open cylinder valve; check cylinder pressure; inspect/clean filter; open flow adjustment knob. |
| Gaslækage ved tilslutninger | Loose connections; damaged seals/O-rings. | Tighten connections; replace damaged seals/O-rings. |
| Upræcis trykaflæsning | Gauge malfunction; incorrect installation. | Ensure correct installation; if issue persists, contact customer support. |
9. Garanti og support
The YESWELDER QB02 Welding Gas Regulator Flow Meter with Gas Hose comes with a 1-ÅRS garanti. For any technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact YESWELDER customer support. 24/7 kundesupport er tilgængelig for at hjælpe dig.
Please refer to the official YESWELDER website or your purchase documentation for detailed warranty terms and contact information.