RENOGY RNG-DCC1212-60-JP

Renogy DC-DC 12V 60A Battery Charger Instruction Manual

Model: RNG-DCC1212-60-JP

1. Sikkerhedsoplysninger

Please read all instructions and warnings in this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

  • Always wear appropriate personal protective equipment, including eye protection, when working with batteries and electrical systems.
  • Ensure all connections are tight and secure to prevent loose connections that can cause excessive heat and damage.
  • Do not operate the charger in wet or damp forhold.
  • Sørg for tilstrækkelig ventilation omkring opladeren for at forhindre overophedning.
  • Afbryd alle strømkilder, før du udfører vedligeholdelse eller fejlfinding.
  • Do not attempt to disassemble or repair the charger yourself. Contact qualified service personnel.

2. Produktet er slutview

2.1 Nøglefunktioner

  • Alsidig batterikompatibilitet: The Renogy DC-DC charger is compatible with multiple alternator types and sub-battery types, including AGM, flooded, gel, and lithium-ion batteries.
  • Smart 3-Stage Opladning: This battery charger charges the sub-battery from the starter battery using a 3-stage charging process (bulk, boost, float), ensuring optimal and automatic 100% charge.
  • Main Battery Over-Discharge Protection: The DC-DC battery charger identifies whether the generator is running, preventing over-discharge of the starter battery and protecting the main battery.
  • Forbedret sikkerhed: Giver overvolumentage protection, over-temperature protection, and reverse polarity protection, ensuring safe operation. It also isolates input and output to prevent voltage transmission errors and protect the house battery from overcharging.
  • Holdbart design: Features a compact and robust construction for reliable performance.

2.2 Produktdimensioner

Renogy DC-DC Charger with dimensions: 31.1 cm length, 17.5 cm width, 6.8 cm height

The image above shows the Renogy DC-DC Charger with its dimensions: 31.1 cm length, 17.5 cm width, and 6.8 cm height.

2.3 Beskrivelse af dele

Diagram of Renogy DC-DC Charger ports and indicators

This diagram illustrates the various ports and indicators on the Renogy DC-DC Charger.

#MærkeBeskrivelse
1Input (+)Main Battery Positive
2Input (-)Main Battery Negative
3StrømindikatorStrømindikator LED
4FejlindikatorError Indicator LED
5S1 S2 S3 S4 S5Battery Type Setting Switch (DIP Switches)
6RJ11Temperature Sensor Connection Port
7D+Signal Line Connection Port
8LCCurrent Limit Port
9Output (+)Sub-battery Positive
10Output (-)Sub-battery Negative

3. Opsætning og installation

3.1 Tilslutningsdiagram

Wiring diagram for Renogy DC-DC Charger connecting to main and sub-batteries in an RV

This diagram illustrates the wiring connections for the DC-DC Charger in a typical RV setup, connecting to both the main (starter) battery and the sub-battery (house battery).

  • DC-DC Charger ↔ Main Battery Wiring
  • DC-DC Charger ↔ Sub-battery Wiring
  • DC-DC Charger D+ Port ↔ Alternator D+ Terminal Wiring

Note: All wiring requires separate purchase. Cables are not included with this product; please prepare them separately if needed.

3.2 DIP-switchindstillinger

DIP switch settings for Renogy DC-DC Charger to adjust battery type and charging voltage

The image shows the DIP switches used to configure the charger. By operating the 5 switches (S1-S5), you can adjust the battery type and charging voltage.

  • S1 and S2: Set Absorption Voltage
  • S3 and S4: Sæt Float Charge Voltage
  • S5: Set Charging Mode

3.3 Valg af kabelstørrelse

Table showing recommended cable sizes and fuse ratings for different DC-DC charger models

Refer to this table for recommended cable sizes and fuse ratings based on your specific DC-DC charger model and cable length.

ModelKabelMinimum kabelstørrelseSikring
DCC-1212-20Hovedbatteri0.61m 5.5sq2.44m 5.5sq4.88m 8.0sq9.75m 22sq30A
Underbatteri0.61m 3.5sq2.44m 3.5sq4.88m 5.5sq9.75m 14sq25A
DCC-1212-40Hovedbatteri0.61m 14sq2.44m 14sq4.88m 22sq9.75m 38sq60A
Underbatteri0.61m 8.0sq2.44m 8.0sq4.88m 14sq9.75m 22sq50A
DCC-1212-60Hovedbatteri0.61m 22sq2.44m 22sq90A
Underbatteri0.61m 14sq2.44m 14sq4.8m 22sq75A
D+/LC0.75~1.2SQ

3.4 D+ and LC Ports

Close-up of D+ and LC ports on Renogy DC-DC Charger

The image highlights the D+ and LC ports on the charger.

  • D+ Port: Connects to the alternator's D+ terminal for smart alternator detection.
  • LC Port: By connecting to the LC port, the charging current can be limited by half. (Recommended cable size: 0.75~1.2SQ)

4. Betjening

4.1 3-Stage Opladningsproces

Graf der illustrerer 3-ernetage charging process: Bulk, Absorption, and Float

The graph above illustrates the 3-stage charging process (Bulk, Absorption, Float) that fully charges the battery.

  • Bulk: Charges the battery at the maximum current until it reaches a set voltage.
  • Absorption: Ladninger ved konstant volumentage.g. reducerer strømmen, når batteriet nærmer sig fuld opladning.
  • Flyde: Holder batteriet på en konstant, lav lydstyrketage to prevent self-discharge.

4.2 LED-indikatorer

The charger features LED indicators to communicate the charging status and battery type. Refer to the tables below for detailed explanations.

Batteritypeindikator
FarveStatusBeskrivelse
GrønONSLA (standard)
GulONGEL
RødONFLD (Oversvømmet)
BlåONLI (Lithium)
HvidONUser (Requires BT-2 Module and Renogy DC Home App)
Service batteri indikator
FarveStatusBeskrivelse
GrønONBatteri fuld
GulONBatteri voltage normal
RødONBatteri undervoltage
RødLangsomt blinkendeBatteri over afladet
RødHurtigt blinkendeBatteri over voltage/over temperatur

Note: Opladningsindikatoren kan ændre sig under følgende forhold:

  1. Rød til gul: Når voltage når 12.2V under voltage opsving.
  2. Gul til rød: Når voltage falder til 12.0V under voltage advarsel.
  3. Gul til grøn: A. Når den når konstant voltage ladetilstand, ladestrømmen er mindre end 3A, varer i 30 sekunder; B. Når ladestrømmen er højere end 3A, bliver den ved med at oplade, indtil den når konstant voltage -tilstanden og strømmen falder til under 3A, varer 30 sekunder.
Generator / opladningsindikator
FarveStatusBeskrivelse
GrønONGeneratoren oplader servicebatteriet
RødLangsomt blinkendePV oplader startbatteriet
SLUKKETOplader ikke

4.3 Alternator Type and Starting Battery Voltage

GeneratortypeStarting Battery Voltage
IndskæringAfskæring
Traditionel generator>13.2V, for 15 seconds<12.7V
Smart generator>12.0V, for 15 seconds<11.5V

4.4 Charging Current Distribution (Solar + Alternator)

ModelRBC30DISRBC50DIS
Kun solenergi30A50A
Only Alt30A50A
Solar + ALT15A + 15A25A + 25A

When using both solar and alternator inputs, the current is split. For example, the RBC30DIS model will provide 15A from solar and 15A from the alternator, totaling 30A.

5. Vedligeholdelse

Regular maintenance ensures optimal performance and longevity of your Renogy DC-DC Charger.

  • Periodically check all wiring connections for tightness and corrosion. Clean any corroded terminals.
  • Inspect the charger for any physical damage or signs of overheating.
  • Ensure the area around the charger is free from dust and debris to maintain proper ventilation.
  • Verify that the battery type settings are correct for your installed batteries.

6. Fejlfinding

If you encounter issues with your DC-DC Charger, refer to the following basic troubleshooting steps:

  • Ingen strøm/LED'er slukket: Check all battery connections and fuses. Ensure the starter battery voltage is above the cut-in threshold.
  • Error Indicator On: Refer to the LED Indicators section (4.2) for the specific error type (over-voltage, over-temperature, reverse polarity, etc.) and take corrective action.
  • Batteri oplades ikke: Verify that the correct battery type is selected using the DIP switches. Check solar panel connections and output, and ensure the alternator is functioning correctly.
  • Reduced Charging Current: Ensure the LC port is not connected if full current is desired. Check cable sizes against recommendations in section 3.3.

For persistent issues, please contact Renogy customer support.

7. Specifikationer

SpecifikationVærdi
MærkeRENOGI
FarveSort
Produktmål (D x B x H)17.5 x 31.1 x 6.8 cm
Udgang Voltage12 volt
OverholdelsesstandarderCE, RoHS
Nominel strøm60 Amps
Producentens modelnummerRNG-DCC1212-60-JP
GTIN (Globalt Handelsidentifikationsnummer)00810009715924
UPC810009715924
ProdukttypeDC-DC oplader
Inkluderede komponenterJapanese Instruction Manual, DC-DC Charger Unit

8. Officiel produktvideo

This video provides a visual guide on how to install and connect the Renogy DC-DC MPPT Charger, demonstrating connections to a starter battery, a lithium house battery, and a solar panel. It also covers setting battery types and understanding LED indicators for charging status.

9. Garanti og support

Dette produkt leveres med en 1 års producentgaranti.

For any questions or support regarding your Renogy DC-DC Charger, please contact our customer service team: