1. Introduktion
The AOPUTTRIVER AP-8801B is a digital light meter designed for accurate measurement of illuminance. It features a wide measurement range, high precision, and various functions including data hold, maximum/minimum value tracking, data storage, and environmental temperature display. This manual provides detailed instructions for the proper use and maintenance of your device.
2. Sikkerhedsoplysninger
- Læs alle instruktioner omhyggeligt, før du betjener enheden.
- Udsæt ikke enheden for ekstreme temperaturer, fugt eller direkte sollys.
- Undgå kraftige stød eller at enheden tabes.
- Hold enheden væk fra vand og andre væsker.
- Forsøg ikke at skille enheden ad eller ændre den. Reparationer bør kun udføres af kvalificeret personale.
- Bortskaf batterier i henhold til lokale regler.
3. Produktet er slutview
3.1 Komponenter
The AP-8801B Digital Light Meter consists of a main unit with an LCD display, control buttons, and a rotatable light sensor.

Figure 1: AP-8801B Digital Light Meter with labeled components.
- Lysdetektor: Sensor for measuring light intensity.
- LCD skærm: Shows measurement readings, units, and other indicators.
- Hold Key/Range Key: Press briefly to hold data; long press to switch auto range mode.
- Max/Min Selection Key: Tryk for at view maximum or minimum recorded data.
- REC-knap: Short press to record data; long press to view lagrede data.
- REL/UP Key: Press to enter relative value mode; long press to view registrerede data.
- MODE Key (Lux/FC, °C/°F): Press to select Lux/FC units; long press to select Celsius/Fahrenheit units.
- Skift knap: Tænd/sluk-knap.
- Beskyttende skal: Provides durability and protection for the device.
3.2 Nøglefunktioner
- Measurement Range: Up to 400,000 Lux / 40,000 FC.
- High Brightness LCD: Black and white display for clear readability in various lighting conditions.
- 270° Rotatable Sensor: The light sensor can be rotated 270° to the left and 90° to the right for flexible measurement angles.
- Data Hold: Freezes the current measurement on the display.
- Max/Min Data Hold: Records and displays the maximum and minimum measured values.
- Data Storage: Stores measurement data for later review.
- Auto Zero: Resets the measurement to zero.
- Auto/Manual Ranging: Automatically selects the appropriate measurement range or allows manual selection.
- Relative Value Measurement: Measures the difference from a reference value.
- Environmental Temperature Display: Shows ambient temperature in Celsius or Fahrenheit.
- Low Battery Indication: Alerts when battery power is low.

Figure 2: The AP-8801B with its rotatable light sensor and clear LCD display.
4. Opsætning
4.1 Batteriinstallation
The AP-8801B requires one 9V battery for operation. To install or replace the battery:
- Find batteridækslet på bagsiden af enheden.
- Åbn dækslet ved at skubbe eller skrue det af.
- Insert a new 9V battery, ensuring correct polarity (+ and -).
- Luk batterirummets dæksel forsvarligt.
When the low battery indicator appears on the LCD, replace the battery promptly to ensure accurate measurements.

Figur 3: Eksample of a low battery indicator on the display.
5. Betjeningsvejledning
5.1 Tænd/sluk
Tryk på det røde Skift knap for at tænde eller slukke for enheden.
5.2 Basic Light Measurement
- Turn on the light meter.
- Ensure the light detector is clean and free from obstructions.
- Point the light detector towards the light source or area where you want to measure illuminance. The sensor can be rotated up to 270° left and 90° right for optimal positioning.
- The current illuminance value will be displayed on the LCD screen in Lux or FC units.

Figure 4: Measuring light with the rotatable sensor.
5.3 Unit Selection (Lux/FC, °C/°F)
Tryk på MODE button to toggle between Lux and FC units for light measurement. Long press the MODE button to switch between Celsius (°C) and Fahrenheit (°F) for temperature display.
5.4 Datahold
Tryk på HOLDE key briefly to freeze the current reading on the display. Press it again to release the hold function and resume live measurement.
5.5 Max/Min Data Hold
Tryk på MAX/MIN key to cycle through the maximum, minimum, and current readings. The display will indicate 'MAX' or 'MIN' when these values are shown.
5.6 Datalagring (REC)
Tryk kort på REC button to record the current data. Long press the REC knappen, og brug derefter REL/UP nøgle til view de lagrede data.

Figure 5: Data storage function indicated on the display.
5.7 Auto/Manual Ranging
The device typically operates in auto-ranging mode. To switch to manual ranging, long press the HOLD/RANGE key. Press again to select different ranges. Long press again to return to auto-ranging.
5.8 Relative Value Measurement
Tryk på REL/UP key to enter relative value mode. The meter will display the difference between the current measurement and a set reference value.
6. Vedligeholdelse
- Rensning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the light detector is kept clean for accurate readings.
- Opbevaring: Når enheden ikke er i brug i længere perioder, skal batteriet fjernes for at forhindre lækage. Opbevar den et køligt og tørt sted, væk fra direkte sollys og ekstreme temperaturer.
- Sensorbeskyttelse: Keep the protective cap on the light sensor when not in use to prevent damage and dust accumulation.
7. Fejlfinding
- Enheden tændes ikke: Check if the battery is installed correctly and has sufficient charge. Replace the battery if necessary.
- Unøjagtige aflæsninger: Ensure the light detector is clean and unobstructed. Verify that the correct measurement unit (Lux/FC) is selected. Check for strong electromagnetic interference nearby.
- Display shows 'OL' (Over-range): The measured light intensity exceeds the current range. If in manual ranging mode, switch to a higher range. If in auto-ranging, the light intensity is beyond the device's maximum capacity.
- Displayet er svagt eller flimrende: Batteriet er muligvis lavt. Udskift batteriet.
8. Specifikationer
| Feature | Specifikation |
|---|---|
| Måleområde | 0.1 to 400,000 Lux / 0.01 to 40,000 FC |
| Accuracy (<10,000 Lux/1,000 FC) | ±4%rdg + 1.0%f.s |
| Accuracy (>10,000 Lux/1,000 FC) | ±5%rdg + 1.5%f.s |
| Opløsning | 0.1 Lux / 0.01 FC |
| Målehastighed | 2 gange / sekund |
| LCD skærmstørrelse | 28.6mm × 51.3mm |
| Sensor Rotation | 270° venstre, 90° højre |
| Strømforsyning | 1 x 9V batteri |
| Produktdimensioner | 21 x 7 x 4 cm |
| Vægt | Approx. 0.3 kg (including battery) |

Figure 6: Product dimensions and recommended illumination levels.
9. Garanti og support
The AOPUTTRIVER AP-8801B Digital Light Meter is covered by a two-year product warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use.
For any concerns, problems, or technical support, please contact AOPUTTRIVER customer service. Please refer to the contact information provided with your purchase or visit the official AOPUTTRIVER webwebsted for hjælp.