DAKASON VPD-4A-50KFD

DAKASON 4FT LED Vapor Tight Light Instruction Manual

Model: VPD-4A-50KFD

1. Introduktion

This manual provides detailed instructions for the safe installation, operation, and maintenance of your DAKASON 4FT LED Vapor Tight Light. Please read this manual thoroughly before installation and retain it for future reference.

The DAKASON 4FT LED Vapor Tight Light is a high-efficiency lighting fixture designed for demanding environments. It features adjustable wattage (40W/50W/60W), 0-10V dimming capability (dimmer not included), and an IP65 rating for resistance against water, dust, and harsh conditions.

2. Sikkerhedsoplysninger

ADVARSEL: Risiko for elektrisk stød. Installationen skal udføres af en kvalificeret elektriker i overensstemmelse med alle nationale og lokale el-forskrifter.

  • Afbryd strømmen ved sikringen eller afbryderen før installation eller service.
  • Sørg for, at forsyningen voltage er kompatibel med armaturet (100-277V).
  • Rør ikke ved strømførende ledninger.
  • Sørg for, at alle forbindelser er sikre og korrekt isolerede.
  • Modificer ikke armaturet.
  • Brug passende personlige værnemidler (PPE) under installationen.
  • This fixture is designed for indoor/outdoor use in wet, damp, and dusty areas.

3. Pakkens indhold

Kontroller, at alle komponenter er til stede, før installationen påbegyndes:

  • 1 x 4FT LED Vapor Tight Lighting Fixture
  • 10 x Stainless Steel Clips
  • 2 x monteringsbeslag
  • 4 x plastikvægpropper
  • 4 x skruer
  • 1 x Waterproof Cable Gland
Contents of the DAKASON 4FT LED Vapor Tight Light package, showing the light fixture, mounting brackets, screws, wall plugs, stainless steel clips, and a waterproof cable gland.

Figure 3.1: Included mounting kit and components.

4. Specifikationer

FeatureSpecifikation
ModelnummerVPD-4A-50KFD
Wattage60W (Adjustable to 50W/40W)
Lumen output6600lm (at 60W)
Farvetemperatur5000K (Day White)
Input bindtage100-277V AC
IP-vurderingIP65 (Vandtæt, Støvtæt)
Dæmpning0-10V dæmpbar (dæmper medfølger ikke)
MaterialePolycarbonat, rustfrit stål
Dimensioner47.2 cm L x 3.74 cm B x 3.38 cm H
Vægt4.91 pund (2.23 kg)
CertificeringerUL-listet
Levetid50,000 timer
DAKASON LED Vapor Tight Light with IP65 rating, showing resistance to water jet, dust particles, condensation, moisture, and harsh environments.

Figure 4.1: IP65 rating details for the vapor tight light.

5. Installationsvejledning

This fixture supports surface/wall mount and suspension mount (additional accessories required for suspension). The following steps detail surface/wall mounting.

  1. Sluk for strømmen: Before starting, ensure electrical power is turned off at the fuse or circuit breaker box to prevent electric shock.
  2. Mark mounting locations: Use the mounting brackets to mark the desired locations for drilling holes on the mounting surface.
  3. Install mounting brackets: Drill holes and secure the mounting brackets to the surface using the provided screws and wall plugs.
  4. Forbered ledningsføring: Open the fixture housing. Feed the supply wire (not included) through the waterproof cable gland. Select the desired wattage (40W/50W/60W) using the internal switch.
  5. Ledningsforbindelser: Connect the supply wires to the LED driver according to the wiring diagram.
    • Black (Line) to L
    • White (Neutral) to N
    • Green (Ground) to Gnd
    • Purple (Dim+) and Gray (Dim-) for 0-10V dimming control (if applicable).
    Tighten the external nut on the waterproof cable gland to ensure a water-tight seal.
  6. Mount fixture: Lift the fixture housing and snap it into place on the installed mounting brackets.
  7. Secure lens: Position the lens onto the fixture housing and secure it with the stainless steel latches/clips. Ensure the lens is tightly sealed with the housing to maintain the vapor-tight integrity.
Step-by-step diagram for hard-wired installation of the DAKASON LED Vapor Tight Light, showing marking, mounting, wiring, and securing the lens.

Figure 5.1: Hard-wired installation steps and wiring diagram.

Video 5.1: Demonstration of mounting bracket installation for the vapor tight light.

6. Betjeningsvejledning

Once installed and wired correctly, the DAKASON LED Vapor Tight Light is ready for operation.

  • Tænd: Restore power at the circuit breaker. The light will illuminate.
  • Wattage Valg: The fixture has a selectable wattage switch (40W/50W/60W) located inside the housing. Adjust this switch før sealing the fixture and restoring power to set the desired light output.
    Image showing the internal switch for selecting 40W, 50W, or 60W power output on the LED vapor tight light.

    Figure 6.1: Internal wattage valgkontakt.

  • Dæmpningsfunktion: If connected to a compatible 0-10V dimmer switch (not included), the light output can be adjusted from 0% to 100%.

    Video 6.1: Demonstration of 0-10V dimming capability in a warehouse setting.

7. Vedligeholdelse

The DAKASON LED Vapor Tight Light is designed for minimal maintenance. Follow these guidelines to ensure optimal performance and longevity:

  • Rensning: Rengør armaturets yderside regelmæssigt med en blød, tør klud.amp cloth. Do not use abrasive cleaners or solvents, as these can damage the polycarbonate housing and lens. Ensure power is off before cleaning.
  • Inspektion: Regularly inspect the fixture for any signs of damage, loose connections, or wear. Pay attention to the waterproof cable gland and stainless steel clips to ensure the seal remains intact.
  • Ingen dele, der kan serviceres af brugeren: There are no user-serviceable parts inside the fixture. Do not attempt to open or repair the LED driver or LED chips. Contact qualified personnel for any repairs.

8. Fejlfinding

If you experience issues with your DAKASON LED Vapor Tight Light, refer to the following troubleshooting guide:

ProblemMulig årsagLøsning
Lyset tænder ikke
  • Ingen strømforsyning
  • Forkert ledningsføring
  • Defekt armatur
  • Tjek afbryder/sikring.
  • Kontroller ledningsforbindelserne (se afsnit 5).
  • Contact customer support if wiring is correct and power is supplied.
Lyset flimrer eller dæmpes uventet
  • Løs ledningsforbindelse
  • Inkompatibel lysdæmperkontakt
  • Strømudsving
  • Kontroller alle ledningsforbindelser.
  • Ensure dimmer is 0-10V compatible.
  • Kontakt en elektriker for at kontrollere strømforsyningens stabilitet.
Reduceret lysudbytte
  • Wattage set to lower setting
  • Beskidt linse
  • Check internal wattage switch (refer to Section 6).
  • Clean the lens (refer to Section 7).

If the problem persists after attempting these solutions, please contact DAKASON customer support.

9. Garanti og support

DAKASON provides a 5 års garanti for this LED Vapor Tight Light, covering defects in materials and workmanship under normal use.

For warranty claims, technical support, or any questions regarding your product, please contact DAKASON customer service through the retailer where the product was purchased or visit the official DAKASON webwebsted for kontaktoplysninger.

Please have your model number (VPD-4A-50KFD) and purchase date available when contacting support.