Dometic DFS

Dometic Mojave Small Doored Furnace 16,000 BTU User Manual

Model: DFS | Part Number: 38917

1. Vigtige sikkerhedsoplysninger

Read all instructions carefully before installing, operating, or servicing this appliance. Failure to follow these instructions could result in property damage, personal injury, or death.

  • Ensure all gas and electrical connections are made by a qualified technician.
  • Verify proper ventilation to prevent carbon monoxide buildup.
  • Opbevar ikke brandfarlige materialer i nærheden af ​​ovnen.
  • Always turn off the gas supply and disconnect power before performing any maintenance or service.

ADVARSEL: Kræft og reproduktionsskader - www.P65Warnings.ca.gov

2. Produktet er slutview

The Dometic Mojave Small Doored Furnace (Model DFS) is a compact, 16,000 BTU heating unit designed for recreational vehicles. It operates on LP Gas and 12V DC power, offering efficient and quiet heating. Its low-profile design allows for flexible installation in various configurations.

Dometic Mojave Small Doored Furnace with dimensions: 7 inches height, 12 inches width, 20 inches depth.

This image displays the Dometic Mojave Small Doored Furnace, highlighting its compact dimensions. The unit measures 7 inches in height, 12 inches in width, and 20 inches in depth, illustrating its suitability for flexible installation in recreational vehicles.

3. Opsætning og installation

This furnace is designed for either horizontal or vertical installation. An outside access door is required and sold separately.

3.1 Udpakning

  • Carefully remove the furnace from its packaging.
  • Inspect the unit for any shipping damage. Report any damage to your dealer immediately.
  • Verify that all components listed in the 'Scope of delivery' (Furnace, Duct Adaptors, and Manual) are present.

3.2 Mounting and Venting

  • Select a suitable location within the RV that allows for proper air circulation and access for maintenance.
  • Ensure adequate clearance around the furnace as specified in the detailed installation manual (refer to Dometic DFSAD12, DFSD12, DFSD16, DFSD20, DFMD16, DFMD20, DFMD25, DFMD30, DFMD35, DFLD35, DFLD40, DFLA35, DFLA40 - Installation Instructions AMER(en) for comprehensive guidance).
  • Install the furnace securely using appropriate fasteners.
  • Connect the exhaust and intake vents to the outside access door (sold separately). Ensure all seals are airtight.

3.3 Gas- og eltilslutninger

  • Connect the LP gas supply line to the furnace. Use only approved gas fittings and ensure all connections are leak-free.
  • Connect the 12V DC power supply to the furnace's electrical terminals. Observe correct polarity.
  • Install any necessary thermostats or control wiring according to the wiring diagram provided in the full installation manual.
  • Test all connections for leaks and proper operation before initial use.

4. Betjeningsvejledning

This section provides general guidance for operating your Dometic Mojave furnace. For detailed operational procedures, refer to the comprehensive operating manual.

4.1 Første opstart

  1. Ensure the LP gas supply is turned on and the 12V DC power is connected.
  2. Open all gas valves leading to the furnace.
  3. Set the thermostat to the desired temperature. The furnace will initiate its ignition sequence.
  4. If the furnace fails to ignite after several attempts, turn off the thermostat, wait a few minutes, and then try again. If issues persist, refer to the troubleshooting section.

4.2 Normal drift

  • The furnace will cycle on and off automatically to maintain the set temperature.
  • The unit is designed for quiet operation due to reduced air turbulence.
  • Monitor the exhaust for proper venting.

4.3 Nedlukning

  • To turn off the furnace, set the thermostat to its lowest setting or to the 'OFF' position.
  • For extended periods of non-use, turn off the LP gas supply valve.

5. Vedligeholdelse

Regular maintenance ensures optimal performance and longevity of your furnace. Always disconnect power and turn off the gas supply before performing any maintenance.

5.1 Årlig inspektion

  • Have a qualified service technician inspect the furnace annually.
  • Kontroller alle gasforbindelser for utætheder.
  • Inspect the exhaust and intake vents for obstructions or damage.
  • Clean the blower wheel and motor if necessary.

5.2 Rengøring

  • Keep the area around the furnace clear of dust, debris, and flammable materials.
  • Periodically clean the exterior of the furnace with a damp klæde. Brug ikke slibende rengøringsmidler.

6. Fejlfinding

Refer to this table for common issues and their potential solutions. If the problem persists, contact a qualified service technician.

ProblemMulig årsagLøsning
Furnace does not igniteNo LP gas supply, faulty ignition, power issueCheck gas tank level and valve. Verify 12V DC power. Consult service manual for ignition system.
Furnace cycles on and off too frequentlyRestricted airflow, incorrect thermostat settingEnsure vents are clear. Adjust thermostat.
Ingen varmeafgivelseNo gas, blower not operating, thermostat issueCheck gas supply. Verify electrical connections. Test thermostat.
Usædvanlige lydeLoose components, debris in blowerInspect for loose parts. Clean blower area.

7. Specifikationer

MærkeDometic
Model infoDFS (DFSD16111)
Varenummer38917
Cooling Power (BTU)16,000
BrændstoftypeLiquid Gas (LPG)
Voltage12V DC
Input Current (DC)4.3 A
Produktmål (H x B x D)7" x 12" x 20"
Varens vægt20.8 lbs
Materiale TypeStål
Støjniveau51 decibel
CertificeringETL

8. Garanti og support

Dometic products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty details, claims, or technical support, please refer to the documentation included with your purchase or visit the official Dometic webwebsted.

It is recommended to register your product to facilitate warranty service and receive important product updates.