Perel EDIN305N

Perel EDIN305N Digital Weekly Timer User Manual

Model: EDIN305N

Indledning

The Perel EDIN305N is a 230V 16A 3600W DIN-rail mount digital weekly timer designed for indoor use. This device allows for precise, programmable control of electrical circuits, enabling automatic switching ON and OFF of connected appliances or lighting systems over a weekly cycle. It features a clear digital display and multiple programming options to suit various scheduling needs.

Sikkerhedsforanstaltninger

ADVARSEL: Electrical installation should only be performed by a qualified electrician. Incorrect wiring can lead to electric shock, fire, or damage to the device and connected equipment. Always disconnect power at the main circuit breaker before installation or maintenance.

  • Ensure the power supply matches the device's specifications (230V~50Hz).
  • Overskrid ikke den maksimale belastningskapacitet på 16A / 3600W.
  • Denne enhed er kun beregnet til indendørs brug. Undgå udsættelse for fugt, støv eller ekstreme temperaturer.
  • Forsøg ikke at åbne eller reparere enheden selv. Overlad al service til kvalificeret personale.
  • Opbevares utilgængeligt for børn.

Produkt overview

The Perel EDIN305N digital timer consists of a main body with a digital display, control buttons, and terminal blocks for electrical connections. A transparent cover protects the display and buttons.

Front view of Perel EDIN305N Digital Weekly Timer showing display, buttons, and terminal blocks.

Figur 1: Front view of the Perel EDIN305N Digital Weekly Timer. The image displays the LCD screen, control buttons (R, W+, H+, M+, C+, Clock, Manual, RES/RCL), and numbered terminal blocks (1, 2 at the top, 3, 4, 5 at the bottom).

Kontrolknapper:

  • R: Reset button (recessed).
  • W+: Weekday setting.
  • H+: Timeindstilling.
  • M+: Minute setting.
  • C+: Clear program.
  • Ur-ikon: Used to set current time and day, and to exit programming mode.
  • MANUEL: Manual override for ON/AUTO/OFF modes.
  • RES/RCL: Reset/Recall program.

Terminalblokke:

  • 1, 2: Power supply input (N, L).
  • 3, 4, 5: Output terminals for controlled circuit (Common, Normally Open, Normally Closed).

Tekniske specifikationer

ParameterVærdi
ModelnummerEDIN305N
Voltage230V~50Hz
Maks. Strøm16A
Maks. Magt3600W
Antal indstillinger7 (TIL/FRA-programmer)
MonteringstypeDIN-skinne
Dimensioner (L x B x H)2.36 x 3.54 x 1.57 tommer (60 x 90 x 40 mm)
Vægt0.12 kg (4.2 ounce)
MaterialePlast
FarveHvid
Batterier påkrævetNo (internal battery for memory backup)

Installation

1. Montering

The Perel EDIN305N is designed for DIN-rail mounting. Securely attach the timer to a standard 35mm DIN-rail within an electrical enclosure. Ensure sufficient space for wiring and ventilation.

2. Ledninger

VIGTIG: Ensure power is disconnected at the main circuit breaker before proceeding with wiring. Follow local electrical codes and regulations.

Side view of Perel EDIN305N Digital Weekly Timer with wiring diagram.

Figur 2: Side view of the Perel EDIN305N Digital Weekly Timer showing the electrical wiring diagram. It illustrates connections for Neutral (N), Live (L), and the output contacts (1, 2, 3, 4, 5) for controlling a load.

Refer to the wiring diagram (Figure 2) and the terminal block labels on the device:

  • Connect the Neutral (N) wire of your 230V AC supply to terminal 1.
  • Connect the Live (L) wire of your 230V AC supply to terminal 2.
  • For the controlled circuit:
    • Terminal 3: Common contact for the relay output.
    • Terminal 4: Normally Open (NO) contact. The circuit connected here will be ON when the timer is active.
    • Terminal 5: Normally Closed (NC) contact. The circuit connected here will be OFF when the timer is active.
  • Connect the load (e.g., light, appliance) between the Live (L) supply and either terminal 4 (for NO operation) or terminal 5 (for NC operation), with terminal 3 connected to the Live (L) supply. Alternatively, connect the load between terminal 4 or 5 and the Neutral (N) supply, with terminal 3 connected to the Live (L) supply. Consult a qualified electrician for specific load wiring configurations.

Indledende opsætning og drift

1. Tænd og nulstil

After wiring and restoring power, the display will illuminate. If the display is blank or shows erratic characters, press the recessed R (Reset) button using a pointed non-metallic object (e.g., a pen tip). This will clear all settings and restore default values.

2. Indstilling af aktuel tid og dag

  1. Tryk og hold på Ur-ikon knap.
  2. Mens du holder Ur-ikon tryk på W+ to set the current day of the week (1=Monday, 7=Sunday).
  3. Mens du holder Ur-ikon tryk på H+ for at indstille den aktuelle time (0-23).
  4. Mens du holder Ur-ikon tryk på M+ for at indstille det aktuelle minut (0-59).
  5. Slip Ur-ikon button. The time and day are now set.

3. Programmering af tænd/sluk-cyklusser

Timeren understøtter op til 7 tænd/sluk-programmer. Hvert program består af en tænd- og en slukketid.

  1. Tryk på Ur-ikon button once to enter programming mode. The display will show "1 ON".
  2. Trykke W+ to select the day(s) for this program. You can choose a single day, a block of days (e.g., Mon-Fri), or all days.
  3. Trykke H+ to set the ON hour for program 1.
  4. Trykke M+ to set the ON minute for program 1.
  5. Tryk på Ur-ikon knappen igen. Displayet vil vise "1 OFF".
  6. Repeat steps 2-4 to set the OFF day(s), hour, and minute for program 1.
  7. To set additional programs (2-7), press the Ur-ikon button to cycle through "2 ON", "2 OFF", etc., and repeat the setting process.
  8. Når du har indstillet alle de ønskede programmer, skal du trykke på MANUEL knappen for at afslutte programmeringstilstanden og vende tilbage til visning af det aktuelle klokkeslæt.

4. Manuel tilsidesættelse

Tryk på MANUEL knappen gentagne gange for at gennemgå driftstilstandene:

  • PÅ: The output is continuously ON, overriding all programs.
  • BIL: The timer operates according to the programmed ON/OFF cycles.
  • OFF: The output is continuously OFF, overriding all programs.

Sørg for, at timeren er indstillet til AUTO til programmeret drift.

5. Clearing Programs

Sådan sletter du et specifikt program:

  1. Enter programming mode by pressing the Ur-ikon button until the desired program number (e.g., "3 ON") is displayed.
  2. Tryk på C+ button. This will clear both the ON and OFF times for that specific program.
  3. Gentag for andre programmer efter behov.
  4. Trykke MANUEL for at forlade programmeringstilstand.

To clear all programs and reset the device, use the recessed R (Nulstil)-knap.

Opretholdelse

  • Rengør enheden med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Ensure the transparent cover is closed to protect the display and buttons from dust and splashes.
  • Regularly check electrical connections for tightness, especially in high-vibration environments.

Fejlfinding

ProblemMulig årsagLøsning
Displayet er tomt.Ingen strømforsyning; internt batteri er afladet.Check power connections (terminals 1 & 2). Ensure main power is ON. If power is present, press the R (Reset) button. The internal battery recharges when connected to power.
Timer not switching ON/OFF as programmed.Incorrect program settings; timer in manual ON/OFF mode.Verify program settings (time, day, ON/OFF). Ensure the timer is in AUTO tilstand ved at trykke på MANUEL knap.
Connected appliance not receiving power.Incorrect wiring; appliance fault; timer fault.Check wiring according to Figure 2. Test the appliance directly. If wiring and appliance are fine, the timer may be faulty.
Buttons unresponsive or display erratic.Software glitch; low internal battery.Tryk på den forsænkede R (Reset) button. Ensure the timer has been connected to power for at least 24 hours to fully charge the internal battery.

Bortskaffelse

Do not dispose of this product with general household waste. This electronic device contains materials that can be recycled. Please dispose of it at a designated collection point for electrical and electronic equipment waste, in accordance with local regulations.

Garanti og support

Perel products are manufactured to high quality standards. For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your local Perel distributor or retailer. Please have your model number (EDIN305N) and purchase details ready when contacting support.

© 2024 Perel. All rights reserved. Information in this manual is subject to change without notice.