1. Introduktion
The Ardest HW632 is an automatic battery charging control module designed to manage the charging process for 12V-24V lead-acid and lithium-ion batteries. This module features real-time voltage monitoring, automatic charge initiation and termination, and user-configurable voltage settings to prevent overcharging and prolong battery life. It is suitable for various applications, including solar power systems, automotive, and general battery charging setups.

Figure 1: Ardest HW632 Battery Charging Control Module. This image displays the top view of the blue circuit board with its components, including the 3-digit LED display, control buttons, and terminal blocks.
2. Produktfunktioner
- Automatic control circuit connection for simplified setup.
- Automatic charging and power-off functionality to prevent overcharging.
- Realtid voltage monitoring via a 3-digit red LED display.
- Auto-save setting feature retains user configurations.
- Utilizes an ST core chip for reliable performance.
- Integrated LM2596 switch voltage regulator.
- User-configurable start and stop charging voltages.
- On-board momentary push buttons for easy voltage indstilling.
- Module disconnects power supply to prevent battery overcharging.
- Compatible with lead-acid batteries, lithium-ion batteries, nickel-cadmium batteries, nickel-metal hydride batteries, polymer batteries, car batteries, and electric car batteries.
- Suitable for use with solar panels.
3. Specifikationer
| Parameter | Værdi |
|---|---|
| Model | HW632 |
| Input bindtage | DC 10-30V |
| Nominel strøm | 20A |
| Display præcision | 0.1V |
| Kontrol præcision | 0.1V |
| Udgangstype | Direkte output |
| Voltage Tolerance | +/- 0.1V |
| Ansøgningsfelter | 12-24V Storage Battery |
| Dimensioner (L x B x H) | 82 mm x 58 mm x 18 mm (3.23 x 2.28 x 0.71 tommer) |
| Varens vægt | 1.58 ounce |

Figure 2: Dimensions of the Ardest HW632 module. The image shows the module with measurements indicating a length of 82mm, width of 58mm, and height of 18mm.
4. Opsætning og ledningsføring
Proper connection of the HW632 module is crucial for safe and effective operation. Ensure all connections are secure before applying power.
4.1 Komponentidentifikation

Figure 3: Labeled components of the Ardest HW632 module. This image highlights the voltage display digital tube, the 'Start' voltage setting button, the 'Stop' voltage setting button, and the output indicator LED.
4.2 Ledningsdiagram
Connect the charger input and battery detection port to the module as shown in the diagram below. The module requires a DC 10-30V input from your charger. The battery to be charged should be a 12V-24V storage battery.

Figure 4: Wiring diagram for the Ardest HW632 module. This diagram illustrates how to connect a charger input and a 12-24V storage battery to the module's terminal blocks.
4.3 Solar Panel Integration
The HW632 module can also be integrated into a solar charging system. Connect the solar panel output to the module's input, and the module's output to the battery.

Figure 5: Solar panel connection diagram. This image shows the HW632 module connected between a solar panel array and a battery, demonstrating its use in a solar charging setup.
5. Betjeningsvejledning
The module features two push buttons for setting the charging parameters and a 3-digit LED display for real-time voltage overvågning.

Figure 6: Diagram illustrating the 'Using Method' for the Ardest HW632 module, showing the start and stop buttons and their functions for setting voltage and resetting.
5.1 Setting the Start Charging Voltage
- I normal bindtage display state, press the Starte button once. The display will show the current start charging voltage.
- Tryk længe på Starte button for approximately 3 seconds. The digital display will begin to flash.
- While the display is flashing, use the Starte knappen for at øge volumentage value and the Stop knap for at reducere volumentage værdi.
- Once the desired start charging voltage is set, wait for a few seconds without pressing any buttons. The module will automatically save the setting and return to the normal voltage display.
5.2 Setting the Stop Charging Voltage
- I normal bindtage display state, press the Stop button once. The display will show the current stop charging voltage.
- Tryk længe på Stop button for approximately 3 seconds. The digital display will begin to flash.
- While the display is flashing, use the Starte knappen for at øge volumentage value and the Stop knap for at reducere volumentage værdi.
- Once the desired stop charging voltage is set, wait for a few seconds without pressing any buttons. The module will automatically save the setting and return to the normal voltage display.
5.3 Fabriksindstilling
To restore the module to its factory default settings:
- Sørg for, at modulet er tændt.
- Simultaneously press and hold both the Starte og Stop knapper.
- The digital display will show "888", indicating that the factory reset has been performed successfully.

Figure 7: A user's hand interacting with the Ardest HW632 module, demonstrating the process of pressing the control buttons to adjust settings.
6. Vedligeholdelse
The Ardest HW632 module is designed for low maintenance. However, periodic checks can ensure optimal performance and longevity:
- Renhed: Keep the module free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning.
- Forbindelser: Periodically inspect all wiring connections to ensure they are tight and free from corrosion. Loose connections can lead to inefficient operation or damage.
- Miljø: Operate the module within its specified temperature and humidity ranges. Avoid exposing it to extreme conditions.
7. Fejlfinding
If you encounter issues with your Ardest HW632 module, consider the following troubleshooting steps:
- Intet display/Ingen strøm:
- Sørg for, at input voltage er inden for DC 10-30V området.
- Kontrollér alle strømtilslutninger for korrekt polaritet og sikker kontakt.
- Verify that the battery is connected, as the module may not display without a battery connected.
- Batteri oplades ikke:
- Confirm that the start charging voltage is set below the current battery voltage.
- Check the charger's output to ensure it is providing power.
- Inspect all wiring for breaks or loose connections.
- Battery Overcharging:
- Verify that the stop charging voltage is set correctly for your battery type.
- Perform a factory reset (refer to Section 5.3) and reconfigure the voltage indstillinger.
- Forkert bindtage-aflæsninger:
- Ensure connections are clean and secure to avoid voltage dråber.
- Compare readings with a calibrated multimeter if possible.
8. Sikkerhedsoplysninger
Please observe the following safety precautions when installing and operating the Ardest HW632 module:
- Afbryd altid strømmen, før du foretager eller ændrer ledningsforbindelser.
- Ensure correct polarity when connecting the input power and battery. Incorrect polarity can damage the module and connected devices.
- Overskrid ikke den maksimale nominelle strøm på 20A.
- Operate the module in a well-ventilated area to prevent overheating.
- Keep the module away from water, flammable materials, and corrosive substances.
- This module is not a toy. Keep out of reach of children.
- If you are unsure about any installation or operation steps, consult a qualified technician.
9. Garanti og support
The Ardest HW632 Battery Charging Control Module is manufactured by Ardest. For specific warranty information or technical support, please refer to the documentation provided with your purchase or contact your retailer. General inquiries can be directed to the manufacturer via their official support channels.