1. Introduktion
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo JSWm 1AX self-priming centrifugal pump. The JSWm 1AX model is designed for pumping clean water and non-aggressive liquids, suitable for domestic, agricultural, and industrial applications where self-priming capability is required. It features a cast iron pump body, technopolymer impeller and ejector group, and an AISI 304 stainless steel body cover.
Please read this manual thoroughly before installation and use to ensure proper function and to prevent damage or injury.
2. Sikkerhedsoplysninger
Overhold altid følgende sikkerhedsforanstaltninger for at forhindre personskade og beskadigelse af pumpen:
- Elektrisk sikkerhed: Ensure the pump is connected to a properly grounded electrical supply. All electrical work must be performed by a qualified electrician in accordance with local regulations. Disconnect power before any maintenance or service.
- Vandsikkerhed: Do not operate the pump without water (dry running), as this can cause severe damage. Ensure the suction line is always submerged.
- Temperatur: Do not pump liquids above the maximum specified temperature (typically 40°C for this model).
- Tryk: Be aware of system pressure. Ensure all connections are secure to prevent leaks and bursts.
- Bevægelige dele: Hold hænder og tøj væk fra bevægelige dele under drift.
- Installation: Install the pump in a well-ventilated, dry area, protected from frost and direct sunlight. Ensure the pump is securely mounted on a stable surface.
- Børn og uautoriseret personale: Hold børn og uautoriserede personer væk fra pumpen under drift.
3. Produktet er slutview og komponenter
The Pedrollo JSWm 1AX is a self-priming jet pump designed for reliable water transfer. Understanding its main components is crucial for proper installation and maintenance.

Figure 1: Internal components of the Pedrollo JSWm 1AX pump.
The diagram above illustrates the key internal parts of the pump:
- Pumpe Casing: The main body of the pump, typically made of cast iron, which houses the internal components and directs water flow.
- Impeller: A rotating component with vanes that imparts kinetic energy to the fluid, increasing its velocity and pressure.
- Diffuser/Ejector Group: A stationary component that converts the high-velocity fluid from the impeller into higher pressure, and for self-priming pumps, helps create a vacuum to draw water.
- Mekanisk tætning: Prevents water leakage along the pump shaft where it enters the motor housing.
- Motoraksel: Connects the electric motor to the impeller, transmitting rotational power.
- Leje: Supports the motor shaft, allowing smooth rotation and reducing friction.
- Fan Cover: Protects the cooling fan and directs airflow over the motor for heat dissipation.
- Terminal Box: Encloses the electrical connections for the motor, providing protection and access for wiring.
- Electric Motor Stator/Rotor: The core components of the electric motor that generate the rotational force.
4. Tekniske specifikationer
The following table details the technical specifications for the Pedrollo JSWm 1AX pump:
| Specifikation | Værdi |
|---|---|
| Model | JSWm 1AX |
| Fabrikant | PEDROLLO |
| Power (HP / kW) | 0.75 HK / 0.55 kW |
| Max flowhastighed | 60 liter pr. Minut |
| Head (Min-Max) | 17 - 43 meter |
| Sugeportens diameter | 1 tommer |
| Diameter af udløbsport | 1 tommer |
| Voltage | 230 volt (AC) |
| Frekvens | 50 Hz |
| Strøm | 3.6 A |
| Kondensator | 14 µF - 450 VL |
| Isoleringsklasse | F |
| Beskyttelsesvurdering | IP X4 |
| Materiale | Rustfrit stål, støbejern |
| Stil | Jet-Assisted, Residential/Commercial Style |
| Farve | Blå |
| Referencenummer | 8001480140059 |

Figure 2: Pedrollo JSWm 1AX product label with detailed technical data.

Figure 3: Dimensional drawing of the Pedrollo JSWm 1AX pump.
5. Installation og opsætning
Correct installation is critical for the pump's performance and longevity. Follow these steps carefully:
- Beliggenhed: Choose a dry, well-ventilated area, protected from direct sunlight, rain, and frost. The pump should be installed as close as possible to the water source to minimize suction lift. Ensure a stable, level surface for mounting.
- Montering: Secure the pump to a solid foundation using appropriate bolts and vibration-damping pads if necessary. This prevents excessive vibration and noise.
- Rørforbindelser:
- Sugeledning: Use a pipe with a diameter equal to or larger than the pump's suction port (1 inch). Ensure the suction line is airtight to prevent air ingress, which can cause the pump to lose prime. Install a foot valve with a strainer at the end of the suction pipe in the water source to prevent debris from entering the pump and to maintain prime.
- Udløbsledning: Connect the discharge pipe (1 inch diameter) to the pump's outlet. Install a check valve on the discharge side if there is a significant static head or if multiple pumps are used. A gate valve can be installed for flow control.
- Use thread sealant tape on all threaded connections to ensure a watertight seal.
- Elektrisk tilslutning: This pump requires a 230V AC, 50Hz power supply. All electrical connections must be made by a qualified electrician. Ensure the power supply matches the pump's specifications. Connect the pump to a dedicated circuit protected by a residual current device (RCD) and an appropriately rated circuit breaker. Ensure proper grounding.
- Spædning af pumpen: Before initial start-up, the pump body must be completely filled with clean water through the priming port (usually located on top of the pump casing). Open any air release valves on the discharge side to allow air to escape. Close the priming port cap securely once filled.
6. Betjeningsvejledning
Once installed and primed, the pump is ready for operation:
- Indledende opstart:
- Sørg for, at pumpen er fuldt fyldt.
- Open the discharge valve fully or partially, depending on system requirements.
- Tænd for strømforsyningen til pumpen.
- The pump should start and begin to draw water. Monitor for any unusual noises or vibrations.
- Kontroller alle forbindelser for utætheder.
- Normal drift: The pump is designed for continuous duty. Monitor the pump periodically for consistent flow, pressure, and absence of unusual noises. Avoid operating the pump against a closed discharge valve for extended periods, as this can lead to overheating.
- Nedlukning: To stop the pump, simply switch off the power supply. If the pump will be out of use for an extended period, especially in freezing conditions, proceed with winterization.
- Frostbeskyttelse: In areas prone to freezing temperatures, drain the pump completely by removing the drain plug (if present) and disconnecting the suction and discharge pipes. Store the pump in a warm, dry place if possible.
7. Vedligeholdelse
Regelmæssig vedligeholdelse sikrer optimal ydeevne og forlænger pumpens levetid:
- Regelmæssig inspektion: Periodically check the pump for leaks, unusual noises, excessive vibration, or signs of corrosion. Address any issues promptly.
- Renhed: Keep the pump and its surroundings clean and free from debris. Ensure the motor's cooling fins are not obstructed to allow for proper heat dissipation.
- Fodventil/si: Regularly inspect and clean the foot valve strainer in the water source to prevent blockages that can reduce pump performance or cause dry running.
- Vinterisering: As mentioned in the operating instructions, drain the pump completely before the first frost to prevent damage from freezing water.
- Mekanisk tætning: The mechanical seal is a wear part. If persistent leakage occurs from the weep hole below the pump casing, the mechanical seal may need replacement. This should be done by a qualified technician.
- Elektriske forbindelser: Kontrollér regelmæssigt de elektriske forbindelser for tæthed og tegn på korrosion.
8. Fejlfinding
Dette afsnit indeholder løsninger på almindelige problemer, du kan støde på:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pumpen starter ikke | Ingen strømforsyning Motor overbelastning Fastsiddende impeller | Check power connection, circuit breaker, RCD. Reset thermal overload protector (if present) or circuit breaker. Allow motor to cool. Investigate cause of overload. Disconnect power and manually check if impeller rotates freely. Clear any obstruction. |
| Pumpen kører, men der kommer ikke noget vand ud | Pumpen ikke primet Luftlækage i sugeledningen Fodventil tilstoppet eller fastklemt Sugeløft for højt Løbehjulet er beskadiget | Re-prime the pump completely. Check all suction line connections for airtightness. Tighten or re-seal. Inspect and clean foot valve/strainer. Reduce the vertical distance from the water source to the pump. Inspect impeller (requires disassembly by technician). |
| Lavt flow eller tryk | Partial air leak in suction line Clogged strainer/pipes Discharge valve partially closed Impeller wear/damage System demand too high | Check and seal suction line connections. Clean strainer and check pipes for obstructions. Ensure discharge valve is fully open. Inspect impeller (requires disassembly by technician). Verify pump capacity matches system requirements. |
| Overdreven støj eller vibrationer | Cavitation (air in water) Usikret montering Lejeslid Fremmedlegeme i pumpen Fejljustering | Check for air leaks in suction line, ensure adequate water supply. Tighten mounting bolts, ensure pump is on a stable surface. Contact service technician for bearing replacement. Disconnect power and inspect pump casing for obstructions. Ensure pump and motor are properly aligned (if applicable). |
| Motor overophedning | Tør løb Lav voltage Høj omgivelsestemperatur Blokeret ventilation Overdreven belastning | Ensure pump is always primed and has sufficient water supply. Bekræft strømforsyningen voltage er inden for specifikationerne. Sørg for tilstrækkelig ventilation omkring motoren. Clear any obstructions from motor cooling fins. Check for blockages in piping or excessive system resistance. |
If you are unable to resolve an issue using this troubleshooting guide, please contact a qualified service technician or Pedrollo customer support.
9. Garanti og support
Pedrollo products are manufactured to high standards and come with a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Pedrollo webwebstedet for detaljerede garantioplysninger.
For technical support, spare parts, or service inquiries, please contact your authorized Pedrollo dealer or the Pedrollo customer service department. When contacting support, please have your pump's model number (JSWm 1AX) and serial number (if available on the product label) ready.