Cloudray MYJG-50W 220V

Cloudray 50W Laser Power Supply User Manual

Model: MYJG-50W 220V

1. Introduktion

This user manual provides essential information for the safe and efficient operation, setup, and maintenance of your Cloudray 50W Laser Power Supply (Model: MYJG-50W 220V). Please read this manual thoroughly before installation and use to ensure optimal performance and longevity of the product.

2. Produktet er slutview

The Cloudray 50W Laser Power Supply is designed for CO2 laser tubes, offering stable and reliable power for laser engraving and cutting machines. It features advanced control and protection mechanisms to ensure safe and precise operation.

Cloudray 50W Laser Power Supply

Figure 2.1: Cloudray 50W Laser Power Supply (Front View)

Nøglefunktioner:

  • Alsidig kompatibilitet: Compatible with 45W-50W CO2 laser tubes from various manufacturers.
  • Quick Response Speed: Ensures efficient and precise laser operation.
  • Effortless Control and Protection: Features TTL level start/stop functionality, output open circuit protection, TTL signal indication, water through signal indication, and laser output indication.
  • Manuel testfunktion: Includes a button to manually check the output laser.
  • External Ammeter with LCD: Allows real-time monitoring of processing current and status, with a trimmer potentiometer for precise current adjustments.
  • Høj effektivitet: Designed for optimal power delivery and prolonged laser tube service life.
Key features of Cloudray 50W Laser Power Supply

Figur 2.2: Overview of key features including simple control, laser power adjustment, and protection.

Komponentidentifikation:

Detaljeret view of Cloudray 50W Laser Power Supply components: label, ports, ammeter, and fan.

Figur 2.3: Detaljeret view showing the product label, input/output ports, external ammeter connection, and cooling fan.

  • Produktetiket: Contains model number, AC input, DC output, and manufacturer information.
  • Input/output porte: Connectors for power input, control signals, and laser output.
  • External Ammeter: Connects to monitor current output and status.
  • Køleventilator: Provides forced air cooling for heat dissipation.

3. Specifikationer

Table of specifications for Cloudray 50W Laser Power Supply M50 230V

Figure 3.1: Detailed specifications table for the laser power supply.

KategoriParameterVærdi
InputInput bindtageAC230V
AC frekvens47 ~ 440Hz
ProduktionMaks. Output voltage22kV
Maks. Udgangsstrøm22mA
StørrelseL x B x H (mm)171*161*91
Vægt(kg)1.5
Effektivitet91 %
MTBF≥ 30000 timer
Responshastighed≤ 1 ms
VoltagRækkeviddeHøjt niveau≥ 3V
Lavt niveau≤ 0.7V
Miljø-30° ~ +65°
KølingForced air cooling (fan cooling)
Høj temperatur testFull Load / 60°C / 12 hours
Start / Stop Test500 gange 7 sekunder

Note: Dimensions are L x W x H in millimeters. Weight is in kilograms.

4. Opsætning og installation

Proper installation is crucial for the safe and effective operation of your laser power supply. Always ensure the power supply is disconnected from the main power source before performing any wiring or installation procedures.

4.1 Ledningsdiagram

Refer to the following diagram for correct wiring connections. Ensure all connections are secure and properly insulated.

Wiring diagram for Cloudray 50W Laser Power Supply

Figure 4.1: Main wiring diagram showing input power, control signals, and laser output connections.

  • AC Input (L, N, FG): Connect your 220V AC power source to these terminals. FG is for Frame Ground.
  • Høj voltage Output (LASER): Tilslut høj voltage output to your CO2 laser tube. This connection carries high voltage and must be handled with extreme caution.
  • Control Signals (H, L, P, G, IN, 5V): These terminals are for connecting to your laser controller board.
    • H (Switch Laser Control Active High): For laser control via high-level signal.
    • L (Switch Laser Control Active Low): For laser control via low-level signal.
    • P (Water Protection): Connect to your water protection sensor. The laser will not fire if water flow is not detected.
    • G (Signal Ground): Common ground for control signals.
    • IN (Input Control Signal 0-5V): For analog power control (0-5V).
    • 5V (Output Power 5V): Provides 5V output for external devices.
  • For Laser Signal Input: Typically an RJ45 port for specific controller connections.

4.2 External Ammeter Connection

The power supply supports an external ammeter for real-time current monitoring. Connect the ammeter as shown below.

Connection of external ammeter to Cloudray 50W Laser Power Supply

Figure 4.2: Connection of the external ammeter to the power supply's dedicated port.

The external ammeter provides a digital display for current output and status indicators for water protection and laser signal. The trimmer potentiometer on the ammeter allows for fine-tuning of the current.

External ammeter display showing current and status indicators

Figure 4.3: Ammeter display showing current output and status indicators (Water protection, Laser signal).

5. Betjeningsvejledning

5.1 Tænd/sluk

  1. Sørg for, at alle forbindelser er korrekte og sikre, før du tilslutter strømmen.
  2. Turn on the main power switch to the laser machine. The power supply will initialize.
  3. To power off, turn off the main power switch.

5.2 Laser Test Function

The power supply includes a "TEST" button for manually checking the laser output. This is useful for troubleshooting or initial setup.

  • Locate the red "TEST" button on the power supply unit.
  • Press and hold the button to activate the laser output. The laser will fire at a low power setting.
  • Release the button to stop the laser output.
  • Forsigtighed: Never look directly into the laser beam. Always wear appropriate laser safety glasses when performing this test.

5.3 Nuværende justering

The laser output current can be adjusted using the trimmer potentiometer on the external ammeter. Rotate the knob to increase or decrease the current as needed for your application. Monitor the current display on the ammeter during adjustment.

5.4 Sikkerhedsfunktioner

  • TTL Level Start/Stop: Allows for precise control of laser firing via digital signals from your controller.
  • Output Open Circuit Protection: Protects the power supply from damage if the laser tube connection is interrupted.
  • Water Through Signal Indication: The power supply will not allow the laser to fire if the water cooling system is not functioning correctly, indicated by the water protection status on the ammeter.
  • Laser Output Indication: Provides visual feedback when the laser is actively firing.

6. Vedligeholdelse

Regular maintenance ensures the longevity and optimal performance of your Cloudray Laser Power Supply.

  • Hold rent: Periodically clean the exterior of the power supply, especially the fan vents, to ensure proper airflow and prevent overheating. Use a soft, dry cloth.
  • Tjek forbindelser: Regularly inspect all wiring connections (AC input, laser output, control signals) to ensure they are tight and free from corrosion or damage.
  • Miljøforhold: Ensure the power supply operates within the specified environmental temperature range (-30°C to +65°C) and humidity levels.
  • Ventilatorbetjening: Verify that the cooling fan is operating freely and quietly. A noisy or non-functioning fan may indicate a problem.

7. Fejlfinding

This section provides solutions to common issues you might encounter with your laser power supply. For problems not listed here, please contact Cloudray customer support.

ProblemMulig årsagLøsning
Ingen laserudgang
  • Ingen strøm til enheden.
  • Løs eller forkert ledningsføring.
  • Water protection activated (no water flow).
  • Controller signal issue.
  • Faulty laser tube.
  • Check main power connection and fuse.
  • Verify all wiring according to Section 4.1.
  • Ensure water cooling system is running and water flow is detected. Check water protection sensor.
  • Verify TTL signals from the controller.
  • Test laser tube with the manual test button (Section 5.2). If still no output, the tube may be faulty.
Ammeter shows 0mA or incorrect reading
  • Ammeter not connected properly.
  • Ammeter or power supply fault.
  • Check ammeter connections (Section 4.2).
  • Ensure the ammeter is functional.
Overophedning
  • Blokerede ventilatoråbninger.
  • Faulty cooling fan.
  • Drift i høj omgivelsestemperatur.
  • Clean fan vents and ensure clear airflow.
  • Check fan operation. Replace if faulty.
  • Sørg for, at driftsmiljøet er inden for det angivne temperaturområde.

8. Garanti og support

Cloudray products are manufactured to high quality standards. For warranty information, please refer to the warranty card included with your product or visit the official Cloudray website. If you encounter any issues or require technical assistance, please contact Cloudray customer support through the vendor's contact information provided at the point of purchase or via their official channels.

For mere information og ressourcer, besøg Cloudray Store on Amazon.

© 2025 Cloudray. All rights reserved.