1. Introduktion

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Eltako WSZ15DE-32A Digital AC Current Meter. Please read this manual thoroughly before using the device and retain it for future reference.

2. Sikkerhedsoplysninger

ADVARSEL: Fare for elektrisk stød. Installation og vedligeholdelse bør kun udføres af kvalificeret personale.

  • Afbryd altid strømmen før installation eller vedligeholdelse.
  • Sørg for, at alle forbindelser er sikre og korrekt tilsluttede i henhold til diagrammet.
  • Betjen ikke enheden, hvis den er beskadiget.
  • Overhold alle lokale og nationale elektriske forskrifter.
  • The device is designed for indoor use in dry environments.

3. Produktet er slutview

The Eltako WSZ15DE-32A is a single-phase digital AC current meter designed for measuring energy consumption. It features a clear LCD display and S0 output for pulse counting.

Eltako WSZ15DE-32A Digital AC Current Meter front view med etiket

Figur 3.1: Forside view of the Eltako WSZ15DE-32A meter. This image displays the front of the meter, showing the model number WSZ15DE-32A, the Eltako brand logo, and the technical specifications printed on the label, including wiring instructions for Phase IN/OUT, Neutral, and S0 output terminals. The LCD display is visible, showing a reading of '00000.00'.

Nøglefunktioner:

  • Single-phase energy meter, Class B
  • Rated current: 0.25-5(32)A
  • Voltage: 230V 50Hz
  • Driftstemperatur: -25°C til +55°C
  • LCD display for energy readings
  • S0 output: 1000 Imp/kWh (LCD), 2000 Imp/kWh (S0 output)
  • DIN-skinnemontering

4. Opsætning og installation

The Eltako WSZ15DE-32A is designed for DIN rail mounting. Follow these steps for proper installation:

  1. Montering: Securely attach the meter to a standard DIN rail in an electrical distribution box. The meter features clips on the back for easy installation.
  2. Eltako WSZ15DE-32A Digital AC Current Meter side view showing DIN rail clips

    Figur 4.1: Side view viser DIN-skinnemonteringsklemmer. This image shows the side and back of the Eltako WSZ15DE-32A meter, highlighting the integrated clips designed for secure attachment to a standard DIN rail.

  3. Ledningsføring: Refer to the wiring diagram on the device label for correct connections.
    • Connect the incoming phase (L) to the 'IN' terminal.
    • Connect the outgoing phase (L) to the 'OUT' terminal.
    • Connect the incoming neutral (N) to the 'N' terminal.
    • Connect the outgoing neutral (N) to the 'N' terminal.
    • For S0 pulse output, connect S0+ and S0- terminals to a compatible pulse counter or data logger.
    Eltako WSZ15DE-32A Digital AC Current Meter close-up of wiring diagram and display

    Figure 4.2: Close-up of wiring diagram and display. This detailed image focuses on the wiring terminals and the LCD display of the Eltako WSZ15DE-32A meter. The diagram clearly illustrates connections for Phase (IN/OUT), Neutral (N), and S0 output (S0+/S0-), along with the energy reading on the LCD.

  4. Verifikation: After wiring, double-check all connections for tightness and correctness before restoring power.

5. Betjeningsvejledning

Once installed and powered, the Eltako WSZ15DE-32A meter will automatically begin measuring and displaying energy consumption.

Læsning af displayet:

The LCD display shows the total accumulated energy consumption in kilowatt-hours (kWh). The reading is typically displayed with two decimal places.

S0 Pulse Output:

The S0 output provides electrical pulses proportional to the energy consumed. This can be connected to external systems for remote monitoring or data logging. The pulse rate is 1000 Imp/kWh for the LCD and 2000 Imp/kWh for the S0 output.

6. Vedligeholdelse

The Eltako WSZ15DE-32A is a low-maintenance device. Follow these guidelines:

  • Rensning: Brug en blød, tør klud til at rengøre målerens yderside. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Inspektion: Kontrollér ledningsforbindelserne med jævne mellemrum for tegn på løsning eller beskadigelse.
  • Miljø: Sørg for, at driftsmiljøet forbliver inden for de angivne temperatur- og luftfugtighedsområder.

7. Fejlfinding

If you encounter issues with your Eltako WSZ15DE-32A meter, consider the following:

ProblemMulig årsagLøsning
Skærmen er tomIngen strømforsyning; forkert ledningsføring.Check power supply to the circuit. Verify wiring connections according to the diagram.
Meter not counting energyIncorrect wiring; no load connected.Ensure phase and neutral connections are correct and a load is drawing current.
S0 output not workingIncorrect S0 wiring; incompatible external device.Verify S0+ and S0- connections. Consult the manual for the external pulse counter.

If the problem persists, contact qualified technical support.

8. Specifikationer

Detailed technical specifications for the Eltako WSZ15DE-32A Digital AC Current Meter:

ParameterVærdi
ModelnummerWSZ15DE-32A
TypeEnfaset energimåler
NøjagtighedsklasseKlasse B
Nominel voltage230 volt
Frekvens50 Hz
Nominel strøm0.25-5(32) A
Maksimal strøm32 A
S0 Output Pulse Rate (LCD)1000 Imp/kWh
S0 Output Pulse Rate (S0)2000 Imp/kWh
Driftstemperatur-25°C til +55°C
MonteringstypeDIN skinne
Dimensioner (L x B x H)6.4 x 1.8 x 8.2 cm
Vægt80 gram
CertificeringerCE
Eltako WSZ15DE-32A Digital AC Current Meter dimensions diagram

Figure 8.1: Dimensions of the Eltako WSZ15DE-32A meter. This image illustrates the approximate dimensions of the meter, indicating a width of 2.5 inches (6 cm), which is relevant for installation planning.

9. Garanti og support

Eltako products are manufactured to high-quality standards. For warranty information and technical support, please refer to the official Eltako webwebstedet eller kontakt din lokale forhandler.

Spare parts availability: 1 Year (as per product specifications).

© 2025 Eltako GmbH. All rights reserved.

Denne manual kan ændres uden varsel.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.