1. Introduktion
The Walfront DC 12V 4-Digit Digital LED Counter is designed for precise counting applications. It features a bright LED display, high accuracy, and stable performance. This counter is easy to install and automatically retains the current count value even after power interruption. It supports both incrementing and decrementing counts within a range of 0 to 9999.

Figur 1: Forside view of the Walfront Digital LED Counter, showing the 4-digit red display.
2. Produktfunktioner
- Holdbar konstruktion: Manufactured from high-grade plastic material, ensuring wear resistance, durability, and a long service life.
- Ryd skærm: Equipped with 4 bright LED lights for a clear and easy-to-read display.
- Høj ydeevne: Offers excellent stability, high accuracy, and straightforward setup.
- Dataopbevaring: The count value is automatically saved and retained even when the power supply is disconnected.
- Alsidig anvendelse: Suitable for a wide range of uses in automation equipment and various testing setups.
3. Specifikationer
| Operation Voltage | DC 8-24V |
| Nuværende forbrug | 30mA |
| Tælle retning | Plus or Minus (Increment/Decrement) |
| Tælle rækkevidde | 0-9999 |
| Antal cifre | 4 |
| Display farve | Rød |
| Dimensioner (L x B x H) | Ca. 8 x 4 x 2.5 cm (3.1 x 1.5 x 0.9 tommer) |
| Vægt | 48 g |

Figure 2: Product dimensions of the Walfront Digital LED Counter.
4. Pakkens indhold
Pakken indeholder følgende varer:
- 1 x Digital Display Counter
- 1 x 5-pin connection cable

Figure 3: The included 5-pin connection cable.
5. Opsætning og ledningsføring
Proper wiring is essential for the correct operation of the digital counter. Refer to the diagram below and the terminal descriptions for connection instructions.

Figure 4: Wiring diagram and terminal identification on the back of the counter.
Beskrivelser af ledningsterminaler:
- Terminal 1: Positive Power Supply (DC 8-24V)
- Terminal 2: Negative Power Supply / Ground
- Terminal 3: Signal Ground (Common with Terminal 2)
- Terminal 4: Clear Input (Connect this terminal to Ground (Terminal 2 or 3) to reset the counter to 0.)
- Terminal 5: Switch Pulse Signal Input (This terminal is for general pulse input. Its specific function may vary or be unused depending on the application.)
- Terminal 6: Count Up Input (Blue wire) - Connect this terminal to Ground (Terminal 2 or 3) to increment the count by one.
- Terminal 7: Count Down Input (Black wire) - Connect this terminal to Ground (Terminal 2 or 3) to decrement the count by one. The count will not go below 0.
Vigtig bemærkning: The input signals for Clear, Count Up, and Count Down are active low. This means that to trigger these functions, the respective terminal must be connected to the Ground (negative power supply). An open state (not connected) is considered OFF, and a connection to Ground is considered ON.
6. Betjening
Once properly wired and powered on, the counter will display the current count. The operation is straightforward:
- Tænd: Apply DC 8-24V power to Terminal 1 (Positive) and Terminal 2 (Negative). The display will illuminate with the last saved count.
- Increment Count: Briefly connect Terminal 6 (Blue wire) to Ground (Terminal 2 or 3). The displayed count will increase by one.
- Decrement Count: Briefly connect Terminal 7 (Black wire) to Ground (Terminal 2 or 3). The displayed count will decrease by one. The counter will not display negative values; it will stop at 0.
- Clear Count: Briefly connect Terminal 4 to Ground (Terminal 2 or 3). The displayed count will reset to 0.
- Power Off Data Retention: The counter automatically saves the current count. When power is restored, the counter will display the last recorded value.
7. Vedligeholdelse
The Walfront Digital LED Counter requires minimal maintenance. Follow these guidelines to ensure optimal performance and longevity:
- Rensning: Brug en blød, tør klud til at rengøre displayet ogasing. Undgå slibende rengøringsmidler eller opløsningsmidler.
- Miljø: Operate the device within its specified temperature and humidity ranges. Avoid exposure to excessive moisture, dust, or direct sunlight.
- Forbindelser: Kontrollér regelmæssigt alle ledningsforbindelser for at sikre, at de er fastgjorte og fri for korrosion.
- Strømforsyning: Ensure a stable DC 8-24V power supply is used to prevent damage to the unit.
8. Fejlfinding
If you encounter issues with your digital counter, refer to the following troubleshooting steps:
- Ingen visning:
- Check if the power supply (DC 8-24V) is correctly connected to Terminal 1 (Positive) and Terminal 2 (Negative).
- Kontroller, at strømforsyningen er aktiv og leverer den korrekte lydstyrke.tage.
- Counter Not Responding to Input:
- Ensure that the input terminals (Terminal 4, 6, or 7) are correctly connected to Ground (Terminal 2 or 3) when triggering a count or clear action. Remember inputs are active low.
- Check for loose or faulty wiring connections.
- Confirm that the pulse signal duration is sufficient for the counter to register.
- Incorrect Count:
- Verify that the correct input terminal (Terminal 6 for Up, Terminal 7 for Down) is being triggered.
- Ensure there are no unintended short circuits or intermittent connections causing spurious counts.
If the problem persists after following these steps, please contact Walfront customer support for further assistance.
9. Garanti og support
Walfront products are manufactured to high-quality standards. In the unlikely event of a product defect, please refer to your purchase documentation for warranty details and return policies. For technical support or inquiries, please contact Walfront customer service through the retailer where the product was purchased.