EBARA 25LPD5.15

EBARA LPD Type Line Pump

Model: 25LPD5.15 Instruction Manual

1. Introduktion

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the EBARA LPD Type Line Pump, Model 25LPD5.15. Please read this manual thoroughly before using the product and keep it for future reference.

2. Sikkerhedsoplysninger

Vigtige sikkerhedsinstruktioner:

  • Afbryd altid strømmen, før du udfører vedligeholdelse eller inspektion.
  • Sørg for korrekt jording for at forhindre elektrisk stød.
  • Do not operate the pump with damaged wiring or components.
  • Brug passende personlige værnemidler (PPE) under installation og vedligeholdelse.
  • Se lokale elektriske forskrifter og bestemmelser for installation.

3. Produktet er slutview

The EBARA LPD Type Line Pump 25LPD5.15 is a compact and lightweight inline pump designed for various industrial and commercial applications. Its inline configuration allows for direct installation within existing piping systems, minimizing the required installation space. The design also facilitates easy disassembly and inspection without the need to remove the entire piping.

Nøglefunktioner:

  • Kompakt og let: Inline design saves space.
  • Nem vedligeholdelse: Disassembly and inspection possible without removing piping.
  • Alsidige applikationer: Suitable for cold/hot water circulation, various machine sets, and general water supply.
EBARA LPD Type Line Pump 25LPD5.15

Figure 1: EBARA LPD Type Line Pump 25LPD5.15. This image shows the compact, inline design of the pump, highlighting its integration capability within a piping system.

4. Opsætning og installation

4.1 Udpakning og inspektion

  • Tag forsigtigt pumpen ud af emballagen.
  • Inspect the pump for any visible damage that may have occurred during transit.
  • Kontroller, at alle komponenterne på pakkelisten er til stede.

4.2 Montering

  • The LPD type pump is designed for inline installation directly into the piping system.
  • Ensure the mounting location is stable, level, and can support the weight of the pump and associated piping when filled with liquid.
  • Sørg for tilstrækkelig plads omkring pumpen til ventilation og adgang til fremtidig vedligeholdelse.

4.3 Rørforbindelser

  • Connect the pump to the piping system, ensuring all connections are tight and leak-free.
  • Use appropriate sealing materials for pipe threads.
  • Ensure the piping is properly supported to prevent strain on the pump casing.

4.4 Elektriske forbindelser

  • Connect the pump to a three-phase 200/220V power supply, matching the frequency of 50Hz.
  • All electrical work must be performed by a qualified electrician in accordance with local codes.
  • Ensure correct wiring for motor rotation.

5. Betjeningsvejledning

5.1 Kontroller før drift

  • Confirm all piping connections are secure and there are no leaks.
  • Sørg for, at pumpen casing is filled with the liquid to be pumped (priming).
  • Check that the power supply matches the pump's requirements.

5.2 Start af pumpen

  • Open the discharge valve gradually after starting the pump.
  • Monitor for unusual noises or vibrations. If detected, shut down immediately and investigate.

5.3 Stop af pumpen

  • Close the discharge valve gradually.
  • Sluk for strømforsyningen til pumpen.

5.4 Væskehåndtering

This pump is designed to handle clean water within a temperature range of 0°C to 100°C. Do not use it for liquids outside this specification or for corrosive/abrasive fluids unless specifically approved by EBARA.

6. Vedligeholdelse

Regular maintenance is crucial for the longevity and optimal performance of your EBARA pump. Always disconnect power before beginning any maintenance procedures.

6.1 Rutinemæssig inspektion

  • Check for leaks around the shaft seal and piping connections.
  • Listen for unusual noises or vibrations during operation.
  • Monitor motor temperature.

6.2 Disassembly and Inspection (without removing piping)

A key feature of the LPD pump is the ability to disassemble and inspect internal components without detaching the pump from the main piping. Refer to the detailed exploded view diagram (not provided in this document, refer to official EBARA service manual) for specific steps. This typically involves:

  1. Shutting down the pump and isolating it from the power supply.
  2. Draining the pump casing.
  3. Removing the motor and impeller assembly from the casing while the casing remains inline.
  4. Inspecting the impeller, mechanical seal, and bearings for wear or damage.
  5. Replacing worn parts as necessary.
  6. Reassembling the pump, ensuring all seals are correctly seated.

6.3 Mechanical Seal Replacement

The pump uses a mechanical seal. If leaks persist from the shaft seal, the mechanical seal may need replacement. This is a precision component and should be handled with care. Consult a qualified technician for replacement if you are unfamiliar with the procedure.

7. Fejlfinding

This section provides solutions to common issues. For problems not listed here, contact EBARA technical support.

ProblemMulig årsagLøsning
Pumpen starter ikkeIngen strømforsyning
Motor overbelastning
Løbehjulet sidder fast
Kontroller strømtilslutning og afbryder
Reset overload protector
Inspect impeller for obstructions
Low flow or no dischargePumpen ikke primet
Suction line air leak
Clogged impeller/piping
Ensure pump is fully primed
Check suction connections for leaks
Clean impeller and piping
Overdreven støj eller vibrationerKavitation
Slidte lejer
Fejljustering
Check suction conditions, ensure adequate liquid supply
Inspicer og udskift lejer
Check pump and motor alignment
Shaft seal leakageSlidt mekanisk tætning
Forkert installation
Udskift den mekaniske tætning
Reinstall mechanical seal correctly

8. Specifikationer

ParameterVærdi
FabrikantEBARA Corporation
Modelnavn25LPD5.15
Caliber (Nominal Diameter)25 mm
Frekvens50 Hz
Produktion0.15 kW
Power VoltageThree-phase 200/220 V
Håndtering af væskeRent vand
Væsketemperaturområde0°C til 100°C
Total sugehoved-6 m (at 20°C)
Impeller TypeLukket
AkseltætningMekanisk tætning
LejeSealed ball bearing (inside motor)
Type / Protection MethodDrip-proof protection type / IP22 (indoor)

9. Garanti og support

For warranty information, technical support, or to order replacement parts, please contact your authorized EBARA distributor or visit the official EBARA website. Keep your purchase receipt and product model number (25LPD5.15) handy when contacting support.

© 2023 EBARA Corporation. All rights reserved.