Duluth Forge DLS-24R-1

Duluth Forge DLS-24R-1 Dual Fuel Ventless Fireplace Logs Set

Model: DLS-24R-1 | Brand: Duluth Forge

1. Introduktion

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Duluth Forge DLS-24R-1 Dual Fuel Ventless Fireplace Logs Set. This unit is designed to operate on either natural gas or liquid propane, offering a versatile heating solution for your indoor space. Please read this manual thoroughly before installation or use and retain it for future reference.

2. Vigtige sikkerhedsoplysninger

ADVARSEL: Forkert installation, justering, ændring, service eller vedligeholdelse kan forårsage personskade eller materielle skader. Se denne manual. For assistance eller yderligere information, kontakt en kvalificeret installatør, et servicebureau eller gasleverandøren.

  • Forslag 65 Advarsel: Dette produkt kan udsætte dig for kemikalier, herunder kulilte, som er kendt af staten Californien for at forårsage fødselsdefekter eller anden reproduktionsskade. For mere information gå til www.P65Warnings.ca.gov.
  • This ventless gas log set is 99.9% efficient and does not require an outside duct or chimney.
  • Equipped with a Safety Pilot O.D.S. (Oxygen Depletion Sensor) that automatically shuts down the unit if carbon monoxide or lack of oxygen is detected.
  • Features Battery-Assisted Piezo ignition for reliable startup.
  • Must be installed in a masonry or agency-approved firebox.
  • Minimum Firebox Size Required: 20 inches (H) x 28 inches (W) in front (23 inches W at rear) x 15 inches (D).
  • Designed for Indoor Use Only.
  • Ensure adequate ventilation in the room where the unit is installed.

3. Opsætning og installation

Professional installation by a qualified technician is highly recommended for gas connections to ensure safety and compliance with local codes.

3.1 Udpakning og inspektion

  • Fjern forsigtigt alle komponenter fra emballagen.
  • Inspect all items for any damage. Contact your retailer immediately if any damage is found.
  • Ensure all listed components are present: 8 Hand Painted Ceramic Logs, Bag of Embers, Remote Control, Receiver Box, AA & AAA Batteries, Hardware Pack, Damper Clamp.

3.2 Batteriinstallation

  • For the Ignition: Install 1 AAA battery into the designated ignition compartment on the main unit.
  • Til fjernbetjeningen: Install 2 AAA batteries into the remote control unit.
  • For the Receiver Box: Install 4 AA batteries into the receiver box.

3.3 Tilslutning af modtageren

Connect the main unit with the receiver, ensuring that the receiver is in the OFF position before connecting. Refer to the included wiring diagram for proper connection.

3.4 Log Placement

The log set includes 8 hand-painted ceramic logs designed for a realistic appearance. Arrange the logs according to the diagram provided in the detailed instruction sheet included with your product. Proper log placement is crucial for optimal flame pattern and safe operation.

Arrangement of 9 hand-painted ceramic logs and glowing embers in a fireplace

Billede: Eksample of log arrangement for a natural appearance.

3.5 Ember Material Placement

Distribute the included bag of glowing ember material over the burner pan to enhance the realistic fire effect. Do not obstruct the burner ports.

Duluth Forge ventless gas logs with flames and glowing embers

Image: The Duluth Forge DLS-24R-1 log set with flames and glowing embers.

4. Betjeningsvejledning

4.1 Lighting the Pilot Flame

  1. Sørg for, at gasforsyningen er åben.
  2. Press lightly on the control knob and turn it counter-clockwise to the PILOT position.
  3. While holding the control knob in, press and hold the TÆNDING button until the pilot flame lights.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot lights to allow the thermocouple to heat up and stabilize the pilot flame. Release the knob slowly. If the pilot goes out, repeat the process.

4.2 Igniting the Main Burner (Remote Control)

Your log set includes a remote control for convenient operation.

Close-up of the remote control for the fireplace logs

Image: Remote control unit with display and buttons.

  1. Ensure the pilot flame is lit and stable.
  2. Set the receiver box to the FJERN position.
  3. Press any button on the remote control to activate its display.
  4. Once the display is active, press the ON button on the remote control to ignite the main flame.

4.3 Adjusting Temperature and Mode

  • Brug MODE button on the remote control to switch between manual mode and automatic constant temperature (thermostat) mode.
  • In thermostat mode, use the up and down arrow buttons to set your desired room temperature. The unit will automatically adjust the flame to maintain this temperature.

4.4 Turning Off the Unit

  • To turn off the main flame, press the SLUKKET knappen på fjernbetjeningen.
  • To turn off the pilot flame, rotate the control knob on the main unit clockwise to the SLUKKET position. Always turn off the pilot flame when the unit will not be used for an extended period.

5. Vedligeholdelse

Regular maintenance ensures the longevity and safe operation of your fireplace logs.

  • Rengøringslogfiler: Periodically inspect the ceramic logs for soot buildup. Clean gently with a soft brush or cloth. Do not use abrasive cleaners.
  • Rengøring af brænder: Keep the burner ports free of dust and debris. Use a vacuum cleaner with a brush attachment to gently clean the burner area.
  • Pilot Assembly: Ensure the pilot assembly and ODS sensor are clean and free from obstructions.
  • Generel pleje: Keep the area around the fireplace clear of combustible materials.

Always ensure the unit is completely cool and the gas supply is turned off before performing any maintenance.

6. Fejlfinding

If you encounter issues, refer to the following common problems and solutions. For persistent problems, contact a qualified service technician.

ProblemMulig årsagLøsning
Pilot will not light or stay lit.No gas supply, air in gas line, thermocouple not heating, ODS sensor dirty.Check gas supply. Bleed air from line. Hold pilot knob longer. Clean ODS sensor.
Hovedbrænderen tænder ikke.Pilot not lit, receiver in OFF position, remote batteries low, gas valve closed.Ensure pilot is lit. Set receiver to REMOTE. Replace remote batteries. Check gas valve.
Fjernbetjeningen reagerer ikke.Low batteries, receiver out of range, receiver in OFF position.Replace remote/receiver batteries. Move closer to unit. Set receiver to REMOTE.
Usædvanlige lugte under drift.Initial burn-off of manufacturing oils/paint, inadequate ventilation.Ensure proper ventilation. Odor should dissipate after initial use. If persistent, consult technician.

7. Specifikationer

FeatureDetalje
ModelnummerDLS-24R-1
MærkeDuluth Forge
Varmeoutput33,000 BTU
VarmedækningOp til 1,300 sq. ft.
BrændstoftypeDobbelt brændstof (naturgas eller flydende propan)
MaterialeCeramic, Oak
Produktmål (D x B x H)15 cm x 20 cm x 28 cm
Varens vægt30 pund
VentilationstypeVent fri
Speciel funktionFjernbetjening
Inkluderede komponenter8 Hand Painted Ceramic Logs, Bag of Embers, Remote Control, Receiver Box, AA & AAA Batteries, Hardware Pack, Damper Clamp
Diagram showing the dimensions of the fireplace log set: 11.5 inches height, 12.5 inches depth, 25 inches length

Image: Product dimensions and minimum firebox requirements.

8. Garanti

This Duluth Forge product comes with a Begrænset garanti. For specific details regarding coverage, duration, and terms, please refer to the warranty information included in your product packaging or contact Duluth Forge customer support directly. Keep your proof of purchase for warranty claims.

9. Kundesupport

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Duluth Forge customer support. Refer to your product packaging or the official Duluth Forge webhjemmeside for de seneste kontaktoplysninger.

© 2024 Duluth Forge. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.