1. Introduktion og overview

The Remotec ZRC-90US Scene Master is a Z-Wave Central Scene Controller designed to enhance your smart home experience. This device allows you to trigger various actions and scenes within your Z-Wave central controller with the simple press of a button. Featuring 8 distinct buttons, each supporting both a short press and a long press, the ZRC-90US can initiate up to 16 different control possibilities.

It serves as an efficient alternative to using a smartphone application for routine tasks, making smart home control accessible for all users, including children, elderly individuals, and guests who may not have access to your mobile application. The ZRC-90US includes a convenient snap-in wall mount, allowing it to be fixed in a preferred location or easily removed for handheld use.

Remotec ZRC-90US Z-Wave Scene Master device

Image 1.1: The Remotec ZRC-90US Z-Wave Scene Master, a compact handheld controller with eight buttons.

2. Produktfunktioner

  • Z-Wave Central Scene Controller: Communicates with your Z-Wave hub to trigger predefined scenes and automations.
  • 8 programmerbare knapper: Each button can be configured for specific functions.
  • 16 Control Possibilities: Supports both short press and long press actions for each of the 8 buttons.
  • Snap-in Wall Mount: Provides flexible placement options, allowing for fixed or portable use.
  • Z-Wave Certification ID: ZC10-15100007, ensuring compatibility within the Z-Wave ecosystem.
  • Frequency Region: U.S./Canada/Mexico (908.42 MHz).
  • Z-Wave Library Version: 6.51.06.
  • Enhedskategori: Handheld Controller.
  • Understøttede kommandoklasser: Device Reset Local, Association, AGI, Battery, Central Scene, Powerlevel, Wake Up.
Z-Wave Plus-logo

Image 2.1: The Z-Wave Plus logo, indicating enhanced features and compatibility.

3. Pakkens indhold

Upon opening your Remotec ZRC-90US package, you should find the following items:

  • Remotec ZRC-90US / BW8510US Z-Wave Scene Master
  • Vægmonteringsbeslag
  • Instruktionsmanual (dette dokument)

4. Opsætning og installation

4.1 Batteriinstallation

The ZRC-90US is battery-powered. To install or replace batteries:

  1. Carefully open the battery compartment cover on the back of the device.
  2. Insert the required batteries (type not specified, please refer to the device's battery compartment markings for correct type and polarity).
  3. Luk batterirummets dæksel forsvarligt.

4.2 Vægmontering

The included wall mount bracket allows for convenient placement of your Scene Master.

  1. Choose a suitable location for the wall mount.
  2. Secure the wall mount bracket to the desired surface using appropriate screws (not included) or adhesive.
  3. Snap the ZRC-90US into the mounted bracket. The device can be easily removed from the bracket for handheld use.

4.3 Z-Wave-inkludering (parring)

To integrate the ZRC-90US into your Z-Wave network, you must perform an inclusion process with your Z-Wave central controller (hub).

  1. Place your Z-Wave central controller into inclusion (pairing) mode. Refer to your controller's instruction manual for specific steps.
  2. On the ZRC-90US, locate the 'L' button (often found within the battery compartment or on the side).
  3. Press the 'L' button tre gange quickly. The device's LED indicator should confirm successful inclusion.
  4. Once included, it is recommended to 'wake up' the device to ensure full communication with the controller. Press the 'W' button (often located in the battery compartment) multiple times until the device is updated by the controller.
  5. Configure the button actions and scenes within your Z-Wave central controller's interface.

Note: Specific configuration steps for button actions (e.g., short press, long press) will vary depending on your Z-Wave hub's software and capabilities. Consult your hub's documentation for detailed scene creation and device configuration.

Remotec ZRC-90US Z-Wave Scene Master with battery compartment open

Billede 4.1: Bagside view of the Remotec ZRC-90US, showing the battery compartment and internal buttons like 'L' and 'W' for Z-Wave operations.

5. Betjeningsvejledning

The Remotec ZRC-90US operates by sending Central Scene commands to your Z-Wave central controller based on button presses. The specific actions performed by these button presses are defined and configured within your Z-Wave hub's software.

5.1 Knapfunktioner

Each of the 8 buttons on the ZRC-90US supports two types of presses:

  • Kort tryk: Et hurtigt tryk og slip af en knap.
  • Langt tryk: Pressing and holding a button for a few seconds until the LED indicator responds (typically a blue light flash).

These 16 distinct events (8 buttons x 2 press types) can be mapped to various scenes, routines, or direct device controls within your Z-Wave network. For example, a short press of Button 1 could turn on your living room lights, while a long press of Button 1 could activate a 'movie night' scene.

5.2 Configuring Actions

All button actions are configured through your Z-Wave central controller's user interface. After successful inclusion, your hub should recognize the ZRC-90US as a Central Scene Controller. You will then be able to create automations or scenes that are triggered by the specific Central Scene commands sent by the ZRC-90US when its buttons are pressed.

6. Z-Wave Specifics

6.1 Z-Wave Exclusion (Removing from Network)

To remove the ZRC-90US from your Z-Wave network:

  1. Place your Z-Wave central controller into exclusion (removal) mode. Refer to your controller's instruction manual for specific steps.
  2. On the ZRC-90US, press the 'L' button tre gange quickly. The device's LED indicator should confirm successful exclusion.

6.2 Device Reset Local

A Device Reset Local command can be used to reset the ZRC-90US to its factory default settings and remove it from any Z-Wave network. This should only be used when the primary controller is missing or inoperable.

To perform a Device Reset Local, consult the specific instructions provided by Remotec or your Z-Wave hub's documentation, as this procedure can vary.

6.3 Wake Up Functionality

The ZRC-90US is a battery-powered device and may enter a low-power sleep mode to conserve battery life. To ensure it communicates with the controller for configuration updates or status checks, you may need to manually 'wake up' the device. This is typically done by pressing the 'W' button (often located inside the battery compartment) multiple times.

7. Fejlfinding

If you encounter issues with your Remotec ZRC-90US, consider the following troubleshooting steps:

  • Enheden reagerer ikke:
    • Kontroller batteriniveauer og udskift om nødvendigt.
    • Ensure the device is within range of your Z-Wave central controller.
    • Verify that the device is properly included in your Z-Wave network. If unsure, attempt re-inclusion.
    • Perform a 'wake up' by pressing the 'W' button to ensure communication.
  • Button Presses Not Triggering Scenes:
    • Confirm that the scenes or automations are correctly configured in your Z-Wave central controller.
    • Ensure the controller is receiving the Central Scene commands from the ZRC-90US. Some controllers may require specific settings (e.g., changing 'device_json' or adding variables) to fully support Central Scene devices. Refer to your hub's community forums or support documentation for advanced configuration.
    • Test with a simple scene to isolate the issue.
  • Problemer med inklusion/eksklusion:
    • Ensure the controller is in the correct inclusion/exclusion mode.
    • Perform the button presses (3x 'L' button) quickly and accurately.
    • Try performing the inclusion/exclusion closer to the Z-Wave central controller.

8. Specifikationer

AttributSpecifikation
ModelnumreZRC-90US, BW8510US
MærkeRemotec
Z-Wave-certificerings-IDZC10-15100007
FrekvensregionU.S./Canada/Mexico (908.42 MHz)
Z-Wave Library Version6.51.06
EnhedskategoriHandheld Controllers
Dimensioner (ca.)4.76 x 3.15 x 1.73 tommer (12.09 x 8.00 x 4.39 cm)
Varens vægt3.52 ounce (99.79 gram)
StrømkildeBattery-powered (Battery type not specified, check device compartment)
Driftstemperatur0°C to 40°C (32°F to 104°F) (Typical for indoor electronics)

9. Sikkerhedsoplysninger

  • Udsæt ikke enheden for fugt eller ekstreme temperaturer.
  • Forsøg ikke at skille enheden ad eller ændre den. Dette vil ugyldiggøre garantien og kan forårsage skade.
  • Bortskaf batterier i henhold til lokale regler. Bland ikke gamle og nye batterier eller forskellige typer batterier.
  • Opbevar enheden utilgængeligt for børn.
  • Use only as intended for Z-Wave home automation control.

10. Garanti og support

For warranty information and technical support, please refer to the documentation provided at the time of purchase or visit the official Remotec webDu kan også kontakte din forhandler for at få hjælp.