True TRUE988284

True 988284 Temperature Control Kit 077B6856 Instruction Manual

Model: TRUE988284

1. Produktet er slutview

The True 988284 Temperature Control Kit 077B6856 is a genuine Original Equipment Manufacturer (OEM) replacement part designed for True Refrigeration units. This kit ensures the proper regulation of temperature within your commercial refrigeration equipment, maintaining optimal operating conditions for safety, reliability, and performance.

True 988284 Temperature Control Kit with dial and capillary tube

Billede 1.1: Overview of the True 988284 Temperature Control Kit, showing the control unit, dial, and capillary tube.

Nøglefunktioner:

2. Sikkerhedsoplysninger

Vigtig: Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

3. Pakkens indhold

Kontroller, at alle komponenter er til stede og ubeskadigede, når du åbner pakken.

Components of the True 988284 Temperature Control Kit including control unit, dial, screws, and connectors

Image 3.1: Contents of the True 988284 Temperature Control Kit, typically including the control module, temperature dial, mounting screws, and electrical connectors.

4. Installationsvejledning

This section provides general guidance for replacing a temperature control kit. Specific installation steps may vary depending on your True Refrigeration model. Refer to your unit's service manual for detailed, model-specific instructions.

  1. Afbryd strømmen: Locate the main power supply to the refrigeration unit and disconnect it. Verify that power is off using a voltage tester.
  2. Access Control Area: Depending on your unit, you may need to remove access panels or grilles to reach the existing temperature control.
  3. Dokumentledningsføring: Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections to the old temperature control. Note the position of the capillary tube sensor.
  4. Fjern gammel kontrol:
    • Carefully disconnect the electrical wires from the old control.
    • Unmount the old control from its housing.
    • Gently remove the capillary tube sensor from its sensing location (e.g., evaporator coil, air return).
  5. Install New Control:
    • Insert the new capillary tube sensor into the exact same sensing location as the old one. Ensure it is securely positioned for accurate temperature readings. Avoid kinking or damaging the tube.
    • Mount the new temperature control module in the same position as the old one using the provided screws.
    • Connect the electrical wires to the new control according to your documented wiring diagram. Ensure connections are secure.
  6. Saml igen: Udskift eventuelle adgangspaneler eller gitre, der blev fjernet.
  7. Gendan strøm: Reconnect the main power supply to the refrigeration unit.
  8. Test drift: Allow the unit to run for a period and monitor the temperature to ensure proper operation and temperature regulation. Adjust the dial as needed.

Note: If you are unsure about any step, consult a qualified refrigeration technician.

5. Betjeningsvejledning

The temperature control kit features a rotary dial for adjusting the desired temperature within your True Refrigeration unit.

6. Vedligeholdelse

The True 988284 Temperature Control Kit is designed for durability and reliability. Regular maintenance of the overall refrigeration unit is crucial for its longevity and efficient operation.

7. Fejlfinding

If your refrigeration unit is experiencing temperature issues after installing this kit, consider the following common troubleshooting steps:

ProblemMulig årsagLøsning
Unit not cooling or too warm
  • Temperature dial set too high (warmer)
  • Capillary tube not properly seated or damaged
  • Løs elektrisk forbindelse
  • Other refrigeration system issues (e.g., low refrigerant, dirty condenser)
  • Adjust dial to a colder setting.
  • Verify capillary tube placement and condition.
  • Check and secure all wiring connections (with power disconnected).
  • Consult a qualified technician for system diagnosis.
Unit freezing contents or too cold
  • Temperature dial set too low (colder)
  • Capillary tube sensing incorrect temperature (e.g., too close to evaporator)
  • Fejl i kontrolenheden
  • Adjust dial to a warmer setting.
  • Ensure capillary tube is correctly positioned away from direct evaporator contact if applicable.
  • If issues persist, the control unit may require replacement or further diagnosis by a technician.
Temperaturen svinger meget
  • Improper capillary tube placement
  • Fejl i kontrolenheden
  • Refrigeration system issues
  • Verify capillary tube placement.
  • Kontakt en kvalificeret tekniker for at få stillet en diagnose.

Advarsel: Do not attempt repairs beyond your technical capabilities. Always prioritize safety and consult a professional for complex issues.

8. Specifikationer

FeatureDetalje
Mærkeægte
ModelnummerSAND988284
Produktdimensioner6 x 6 x 4 tommer
Varens vægt4.8 ounce
DriftstilstandAutomatisk
KontakttypeNormalt åben
Connector TypeSkrueterminaler
TerminalSkrue
Kredsløbstype1-vejs
MonteringstypeOverflademontering
Aktuator typeTryk knap
KontaktmaterialeKobber, Messing
Dato først tilgængelig15. juni 2011

9. Garanti og support

As a genuine OEM part, this True 988284 Temperature Control Kit is manufactured to high standards. For specific warranty information, please refer to the documentation provided with your original True Refrigeration unit or contact True Refrigeration directly.

Kundesupport:

For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact True Refrigeration customer support or an authorized service provider.

Relaterede dokumenter - SAND988284

Preview Ægte Kommerzielle Kühltechnik: Allgemeiner Regelungsleitfaden
Umfassender Leitfaden zur Bedienung, Einstellung und Fehlerbehebung von Temperaturregelungen in True kommerziellen Kühl- und Gefriergeräten. Enthält Anleitungen für mechanische und elektroniske Steuerungen sowie speciel modelinformationen.
Preview TRUE Manufacturing Installationsmanual Lynstartguide
Dette dokument indeholder vigtige retningslinjer for installation, drift og vedligeholdelse af kommercielle køle- og varmeapparater fra TRUE Manufacturing. Det indeholder sikkerhedsadvarsler, specifikationer, opsætningsprocedurer og vedligeholdelsesinstruktioner.
Preview Installationsmanual til True TH-modeller med varmeskabe
Omfattende installations-, betjenings- og vedligeholdelsesvejledning til True TH-modeller af varmeskabe. Dækker sikkerheds-, elektriske, opsætnings-, vedligeholdelses- og garantioplysninger fra True Manufacturing Co., Inc.
Preview Installations- og betjeningsmanual til True T-23DF-HC kommercielt køleskab/fryser
Omfattende installations-, betjenings-, vedligeholdelses- og sikkerhedsvejledning til True T-23DF-HC kommercielt køleskab/fryser med dobbeltkammer. Indeholder fejlfindings-, rengøringsvejledninger og garantioplysninger.
Preview Installationsmanual for True CVM-serien
Omfattende installations-, betjenings- og vedligeholdelsesmanual til True CVM-serien af ​​køleenheder. Dækker sikkerhedsforanstaltninger, elektriske krav, installationsprocedurer, nivellering, forsegling, hyldemontering og generel vedligeholdelse.
Preview Manuel d'Installation og Démarrage Rapide True
Vejledning til fuldførelse af installation, anvendelse og indretning af køle- og kongektionsbeklædning True Manufacturing Co., Inc. Inkluderer informationer om væsentlige sikkerhedsoplysninger og ressourcer for support.