Delta Dore Tybox 23

Delta Dore Tybox 23 Radio Thermostat for Boiler

Model: Tybox 23 (Product Code: 6053035)

1. Introduktion

This instruction manual provides detailed information on the installation, operation, and maintenance of your Delta Dore Tybox 23 Radio Thermostat. This device is designed to wirelessly control your boiler, offering precise temperature management and energy efficiency. Please read this manual thoroughly before installation and use to ensure proper functioning and safety.

2. Sikkerhedsinstruktioner

  • Elektrisk sikkerhed: Installation of the receiver unit involves connection to mains electricity (230V). This task should only be performed by a qualified electrician to prevent electric shock or damage to the device.
  • Batterihåndtering: Use only the specified battery type (2 x LR03 AAA Alkaline). Do not mix old and new batteries, or different types of batteries. Dispose of used batteries according to local regulations.
  • Placering: Ensure the room module is placed in an area free from direct sunlight, drafts, or heat sources that could affect temperature readings.
  • Rensning: Do not use abrasive cleaners or solvents. Clean the device with a soft, dry cloth.
  • Vandeksponering: Denne enhed er ikke vandtæt. Undgå udsættelse for vand eller høj luftfugtighed.

3. Pakkens indhold

Bekræft at alle komponenter er til stede i pakken:

  • 1 x Delta Dore Tybox 23 Room Module (Thermostat)
  • 1 x modtagerenhed
  • 2 x LR03 (AAA) Alkaline Batteries
  • 1 x Plinth for Room Module (for desk placement)
  • 1 x 2-meter connection cable (for receiver)
  • Monteringsudstyr (skruer, vægdyvler)
  • Instruktionsmanual

4. Opsætning

4.1. Room Module Installation

The room module can be installed in two ways:

  1. Vægmontering: Choose a central location in the room, approximately 1.5 meters (5 feet) from the floor, away from direct heat sources, drafts, or direct sunlight. Use the provided mounting hardware to secure the module to the wall.
  2. Plinth Mounting: Attach the room module to the supplied plinth for placement on a flat surface, such as a table or shelf. Ensure stable placement.

4.2. Battery Installation (Room Module)

Open the battery compartment on the back of the room module. Insert the two supplied LR03 (AAA) Alkaline batteries, ensuring correct polarity (+/-). Close the battery compartment securely.

4.3. Receiver Unit Connection

The receiver unit connects directly to your boiler. This connection involves mains voltage (230V) and should only be performed by a qualified electrician.

  • Strømforsyning: Connect the receiver to a 230V power source.
  • Kedeltilslutning: Connect the receiver's dry contact output (NC/NO, 5A) to the appropriate terminals on your boiler, as specified in your boiler's manual. The receiver is supplied with a 2-meter cable for this purpose.

4.4. Pairing (Radio Communication)

The room module and receiver are typically pre-paired at the factory. If pairing is required or lost, refer to the detailed pairing instructions in the full product manual. Generally, this involves pressing a pairing button on the receiver and then initiating a pairing sequence on the room module.

5. Betjeningsvejledning

The Delta Dore Tybox 23 features a clear LCD display and three control buttons: MODE, '-', and '+'.

Delta Dore Tybox 23 radio thermostat displaying 20.2 degrees Celsius, with 'MODE', '-', and '+' buttons below the screen.

Dette billede viser forsiden view of the Delta Dore Tybox 23 radio thermostat. The digital LCD screen clearly displays '20.2°C' as the current temperature, along with an 'ON' indicator and a sun icon, likely indicating a comfort or active heating mode. Below the screen are three grey push buttons: 'MODE' on the left, '-' in the center, and '+' on the right, used for navigating settings and adjusting temperature. The Delta Dore logo is visible at the bottom center of the device.

5.1. Driftstilstande

Tryk på MODE knap til at gennemgå de tilgængelige driftstilstande:

  • Komforttilstand: Maintains the set comfort temperature (e.g., 20°C).
  • Økonomitilstand: Maintains a reduced temperature for energy saving (e.g., 17°C).
  • Frostbeskyttelsestilstand: Maintains a minimum temperature to prevent freezing (adjustable from 5°C to 15°C).
  • Stop Mode (Off): Varmen er slukket.

5.2. Temperaturjustering

In Comfort or Economy mode, use the '+' og '-' buttons to adjust the desired setpoint temperature. The temperature can be adjusted in 0.5°C increments within a range of 5°C to 30°C.

5.3. Baggrundsbelyst skærm

Skærmen er baggrundsbelyst for nem viewing in low-light conditions. It will typically illuminate when a button is pressed.

5.4. Tastaturlås

The keypad can be locked to prevent accidental changes. Refer to the full manual for specific instructions on how to activate and deactivate the keypad lock function.

6. Vedligeholdelse

6.1. Udskiftning af batteri

When the battery low indicator appears on the screen, replace the two LR03 (AAA) Alkaline batteries in the room module. Ensure correct polarity. It is recommended to replace both batteries simultaneously.

6.2. Rensning

Clean the thermostat's exterior with a soft, dry, or slightly damp cloth. Do not use chemical cleaners, abrasives, or solvents, as these can damage the device's surface or internal components.

7. Fejlfinding

  • Ingen skærm/enhed svarer ikke: Check if the batteries in the room module are correctly inserted and not depleted. Replace batteries if necessary.
  • Opvarmning aktiveres ikke:
    • Ensure the thermostat is in Comfort or Economy mode and the setpoint temperature is above the ambient temperature.
    • Check the receiver unit's power supply (230V).
    • Verify the radio connection between the room module and receiver. Re-pair if necessary (refer to full manual).
    • Check the boiler's status and power supply.
  • Unøjagtig temperaturaflæsning: Ensure the room module is not exposed to direct sunlight, drafts, or other heat sources.
  • Sværhedsgradsprogrammering: While the Tybox 23 is designed for ease of use, some users may find initial programming challenging. Refer to the detailed steps in the full manual or contact customer support for assistance.

8. Specifikationer

FeatureSpecifikation
ModelTybox 23 (6053035)
MærkeDelta Dore
Room Module Power Supply2 x 1.5V LR03 (AAA) Alkaline Batteries (included)
Modtager strømforsyning230V
Output kontaktDry contact inverter (NC/NO), 5A
ForbindelsesteknologiRF (Radio Frequency)
Temperaturkontrol typeDigital
Temperaturjusteringsområde5°C to 30°C (in 0.5°C steps)
Frost Protection Range5°C til 15°C
Display TypeGraphic LCD (backlit)
Room Module Dimensions (H x W x D)80 x 80 x 23 mm
Modtagerens dimensioner (H x B x D)100 x 54 x 20 mm (ekskl. antenne)
Produktets vægt390 g
FarveHvid
MonteringstypeWall-mounted or Plinth (Room Module)

9. Garantioplysninger

For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Delta Dore webwebsted. Gem din købsbevis til garantikrav.

10. Support

If you encounter any issues or have questions regarding your Delta Dore Tybox 23 thermostat that are not covered in this manual, please contact Delta Dore customer service or your local distributor for assistance. Contact details can typically be found on the manufacturer's webwebsted eller produktemballage.

Ask a question about this manual