Delta Dore Deltia 8.36

Delta Dore Deltia 8.36 Wireless Programmable Thermostat User Manual

Model: Deltia 8.36 (DEL6050458)

1. Introduktion

The Delta Dore Deltia 8.36 is a wireless programmable thermostat system designed to control electric radiators across up to three distinct heating zones. This system includes a central programmer and six receivers, allowing for precise temperature management and energy savings. The programmer offers four operating modes: Comfort, Economy, Frost Protection, and Off, providing flexible control tailored to your lifestyle.

This manual provides detailed instructions for the installation, operation, and maintenance of your Deltia 8.36 system to ensure optimal performance and comfort.

2. Sikkerhedsoplysninger

Please read all safety instructions before installing or operating the Deltia 8.36 system. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

  • Installationen skal udføres af en kvalificeret elektriker eller en kompetent person.
  • Ensure the main power supply to the heating system is disconnected before any installation or maintenance work.
  • Do not expose the programmer or receivers to water or excessive humidity.
  • Use only the specified battery type (2 x LR03 alkaline batteries) for the programmer.
  • Keep the device away from direct heat sources and strong electromagnetic fields.

3. Pakkens indhold

Bekræft at alle komponenter er til stede i pakken:

  • 1 x Deltia 8.36 Wireless Programmable Thermostat (Programmer)
  • 6 x Wireless Receivers for Electric Radiators
  • Monteringsudstyr (skruer, vægdyvler)
  • Brugervejledning (dette dokument)
Delta Dore Deltia 8.36 programmer and six receivers

Image 3.1: Deltia 8.36 Programmer with six included receivers.

4. Opsætning

4.1. Programmer Installation

  1. Indsæt batterier: Open the battery compartment on the back of the Deltia 8.36 programmer. Insert two LR03 (AAA) alkaline batteries, ensuring correct polarity. Close the compartment.
  2. Placering: The programmer can be placed on a flat surface or mounted on a wall. Choose a central location in your main living area, away from direct sunlight, drafts, or heat sources, to ensure accurate temperature readings.
  3. Vægmontering (valgfrit): If wall mounting, use the provided screws and wall plugs to secure the mounting bracket to the wall. Attach the programmer to the bracket.
Delta Dore Deltia 8.36 wireless thermostat unit

Billede 4.1: Forside view of the Deltia 8.36 programmer unit.

4.2. Installation af modtager

Each receiver controls one electric radiator. Ensure the main power to the radiator circuit is off before installation.

  1. Strømafbrydelse: Turn off the electricity supply to the electric radiator at the main circuit breaker.
  2. Ledningsføring: Connect the receiver to the electric radiator's pilot wire (fil pilote) according to the wiring diagram provided with the receiver. Typically, this involves connecting the phase, neutral, and pilot wire. Consult a qualified electrician if you are unsure.
  3. Montering: Mount the receiver near the radiator, ensuring it is not obstructed and has good wireless communication with the programmer.
  4. Strømgendannelse: Restore power to the radiator circuit.

4.3. Pairing Programmer and Receivers

Follow the specific pairing instructions provided with your receivers. Generally, this involves putting the receiver into pairing mode (often by pressing a button) and then initiating a pairing sequence on the Deltia 8.36 programmer. Repeat for all six receivers and assign them to the desired zones (Zone 1, Zone 2, Zone 3).

5. Betjeningsvejledning

The Deltia 8.36 programmer features a central selector dial and several buttons for easy operation.

5.1. Basic Display Information

The display shows the current ambient temperature, the active operating mode (e.g., sun icon for Comfort, moon icon for Economy), and programming details.

5.2. Valg af driftstilstande

The Deltia 8.36 offers four main operating modes:

  • Comfort Mode (Sun Icon): Maintains the set comfort temperature.
  • Economy Mode (Moon Icon): Maintains a reduced temperature, typically a few degrees below comfort, for energy saving.
  • Frost Protection Mode (Snowflake Icon): Opretholder en minimumstemperatur (f.eks. 7 °C) for at forhindre frysning.
  • Fra-tilstand: Turns off heating for the selected zone(s).

Use the central selector or dedicated buttons (refer to your programmer's interface) to cycle through and select the desired mode for each zone.

5.3. Indstilling af temperatur

To adjust the temperature for the currently active mode:

  1. Ensure the desired mode (Comfort or Economy) is active.
  2. Rotate the central selector dial to increase or decrease the temperature setting. The new temperature will be displayed.
  3. The system will automatically save the new setting after a few seconds.

5.4. Programming Schedules (Weekly)

The Deltia 8.36 allows for customizable weekly programming, adjustable in half-hour increments for each of the three independent zones.

  1. Adgangsprogrammering: Press the 'PROG' button (or similar, refer to your device's specific buttons) to enter programming mode.
  2. Vælg zone: Use the zone selection buttons to choose the zone you wish to program (Zone 1, Zone 2, or Zone 3).
  3. Vælg dag: Navigate through the days of the week using the appropriate buttons.
  4. Set Half-Hour Segments: For each half-hour segment of the day, select the desired operating mode (Comfort, Economy, Frost Protection, or Off). Use the central selector or mode buttons to change the mode for the selected segment.
  5. Copy/Repeat: Some models allow copying programs from one day to another or across zones to simplify setup.
  6. Afslut programmering: Press the 'PROG' button again or wait for the system to automatically exit programming mode.

5.5. Temporary Temperature Override

You can temporarily override the programmed temperature for a specific duration.

  1. While in normal operating mode, rotate the central selector dial to set a new desired temperature.
  2. The display will indicate that a temporary override is active. You may be prompted to set the duration of the override.
  3. The system will revert to the programmed schedule once the override duration expires.

5.6. Absence Management

For extended periods away, utilize the absence management feature to save energy. This allows you to set a lower temperature or turn off heating for a defined period, automatically resuming your schedule upon your return.

5.7. Fjernbetjening (valgfrit)

The Deltia 8.36 can be controlled remotely by adding an interface such as an Aptone 40 or a Deltis telephone transmitter. Refer to the specific instructions for these optional accessories for setup and operation.

6. Vedligeholdelse

The Deltia 8.36 system requires minimal maintenance to ensure reliable operation.

  • Rensning: Wipe the programmer and receivers with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Udskiftning af batteri: The programmer is powered by two LR03 (AAA) alkaline batteries. Replace them when the low battery indicator appears on the display. Dispose of old batteries responsibly.
  • Firmwareopdateringer: Check the Delta Dore webbesøg webstedet regelmæssigt for at se, om der er tilgængelige firmwareopdateringer til din model.

7. Fejlfinding

If you encounter issues with your Deltia 8.36 system, refer to the following common problems and solutions:

  • No Display/Unit Not Responding: Kontroller, om batterierne er korrekt isat og opladet. Udskift batterierne om nødvendigt.
  • Radiator Not Heating/Cooling:
    • Ensure the receiver is properly connected and powered.
    • Verify that the programmer and receiver are paired. If not, re-initiate the pairing process.
    • Check the selected operating mode and temperature setting on the programmer.
    • Ensure there are no obstructions or excessive distances between the programmer and receiver that could interfere with wireless communication.
  • Forkert temperaturaflæsning: Ensure the programmer is not exposed to direct sunlight, drafts, or heat sources that could affect its internal temperature sensor.
  • Programmeringsproblemer: Double-check your programmed schedules for each zone and day. Ensure you have saved your settings correctly.
  • Fjernbetjening virker ikke (hvis relevant): Verify the remote interface (e.g., Aptone 40) is correctly installed and configured according to its own manual.

If the problem persists, contact Delta Dore customer support for assistance.

8. Specifikationer

FeatureSpecifikation
MærkeDelta Dore
ModelnummerDEL6050458
Produktmål (L x B x H)10 x 25 x 15 cm
Varens vægt1 kilo
FarveHvid
MaterialePlast
Voltage230 volt
ForbindelsesteknologiRF, Wired (for receivers)
Speciel funktionTrådløs
Power Source (Programmer)Batteridrevet (2 x AAA, medfølger ikke)
Antal zoner3
Inkluderede komponenter1 Wireless Pilot Wire Programmer, 6 Receivers

9. Garanti og support

For warranty information and customer support, please refer to the official Delta Dore webwebstedet eller kontakt deres kundeservice direkte. Gem din købsbevis til garantikrav.

Delta Dore Contact Information:

  • Webwebsted: www.deltadore.com (Tjek venligst din regionale webwebsted)