Accu-Chek ROC048310

Accu-Chek Nano SmartView System til overvågning af blodsukker

Brugermanual

Indledning

Accu-Chek Nano SmartView Blood Glucose Monitoring System is designed for self-testing to help individuals manage their blood glucose levels. This system provides fast and accurate results, featuring a brilliant backlit display and a small blood sample requirement. It is intended for use with Accu-Chek SmartView teststrimler.

Systemkomponenter

Your Accu-Chek Nano SmartView kit typically includes:

  • Accu-Chek Nano Blood Glucose Meter
  • Accu-Chek FastClix Lancing Device
  • Accu-Chek FastClix Lancets (preloaded in a drum)
  • Accu-Chek SmartView Test Strips (sold separately or included in some kits)
  • Bæretaske
  • Brugermanual

Ensure all components are present and undamaged upon opening the package. If any items are missing or damaged, contact customer support.

Opsætning

1. Batteriinstallation

The Accu-Chek Nano meter requires product-specific batteries, which are typically included. Open the battery compartment on the back of the meter and insert the batteries according to the polarity indicators. Close the compartment securely.

2. Initial Meter Setup

Upon first use or after battery replacement, the meter may prompt you to set the date, time, and measurement units (mg/dL or mmol/L). Follow the on-screen instructions using the meter buttons to configure these settings. Refer to the meter's display for guidance.

3. Accu-Chek FastClix Lancing Device Setup

The Accu-Chek FastClix lancing device uses a drum with 6 preloaded lancets. This design eliminates the need to handle individual lancets.

  1. Indsæt lancettromle: Remove the cap from the lancing device. Insert a new lancet drum into the device. The drum will click into place.
  2. Udskift hætten: Sæt hætten tilbage på fingerprikkeren.
  3. Adjust Penetration Depth: Rotate the comfort dial on the cap to select a penetration depth. Start with a lower setting (e.g., 2 or 3) and adjust as needed to obtain a sufficient blood sample. There are 11 customizable depth settings.
Accu-Chek Nano SmartView Blood Glucose Monitoring System and FastClix Lancing Device

Image: The Accu-Chek Nano meter displaying a reading of 106 mg/dL, alongside the Accu-Chek FastClix lancing device. The lancing device features a comfort dial for depth settings and illustrates the lancet drum insertion process. Key features of the meter are also listed, including no coding, use with SmartView test strips, backlit display, small 0.6 µL sample size, 5-second results, pre- and post-meal markers, and non-fingertip testing option.

Betjeningsvejledning

Udførelse af en blodsukkertest

Follow these steps for accurate blood glucose measurement:

  1. Klargøring af fingerprikkeren: Ensure the FastClix lancing device is loaded with a lancet drum and the depth setting is appropriate. To prime the device, press the priming button until it clicks.
  2. Vask hænder: Wash your hands thoroughly with warm, soapy water and dry them completely. This helps prevent contamination and improves blood flow.
  3. Indsæt teststrimmel: Remove an Accu-Chek SmartView test strip from its vial and immediately close the vial cap tightly. Insert the metallic end of the test strip into the meter. The meter will turn on automatically and display a flashing blood drop symbol.
  4. Få blod Sampdet: Press the primed lancing device firmly against the side of your fingertip (or an approved alternate site if using non-fingertip testing). Press the release button to prick your skin. Gently squeeze your finger to form a small drop of blood.
  5. Apply Blood to Test Strip: Touch the tip of the test strip to the blood drop. The strip will draw the blood into the reaction area. Do not smear the blood.
  6. Læs resultater: The meter will count down and display your blood glucose result in approximately 5 seconds.
  7. Mark Results (Optional): The Accu-Chek Nano allows for pre- and post-meal markers. Use the meter's buttons to apply the appropriate marker to your result if desired.
  8. Dispose of Lancet and Strip: Eject the used test strip and advance the lancet drum in the FastClix device to the next fresh lancet. Dispose of used lancets and test strips safely in a sharps container or according to local regulations.

Test uden fingerspidser

Accu-Chek Nano SmartView system offers an option for non-fingertip testing (e.g., palm, forearm). Consult your healthcare professional before using alternate sites, as results from these sites may differ from fingertip results, especially during periods of rapid glucose change.

Opretholdelse

Rengøring af måleren

Clean the meter regularly to ensure proper function. Wipe the exterior of the meter with a soft cloth dampened with a mild cleaning solution (e.g., 70% isopropyl alcohol). Do not immerse the meter in liquid or spray cleaners directly onto it.

Opbevaring

Store the Accu-Chek Nano meter and test strips in a cool, dry place, away from direct sunlight and extreme temperatures. Keep test strips in their original vial with the cap tightly closed. Refer to the test strip packaging for specific storage temperature ranges.

Udskiftning af batteri

When the low battery indicator appears on the meter display, replace the batteries promptly to avoid interruption of use. Use only the specified battery type.

Fejlfinding

If you encounter issues with your Accu-Chek Nano SmartView system, refer to the following common problems and solutions:

  • Måleren tænder ikke: Kontroller batteriinstallationen, og sørg for, at batterierne er friske.
  • Vist fejlmeddelelse: Consult the full user manual for a list of specific error codes and their meanings. Common errors may relate to insufficient blood sample, expired test strips, or meter malfunction.
  • Upræcise læsninger: Ensure test strips are not expired and stored correctly. Verify proper blood sample application. Perform a control solution test if available, or contact customer support if discrepancies persist.
  • Difficulty Obtaining Blood Sampdet: Adjust the lancing device's penetration depth. Ensure the lancing device is primed before use.

For persistent issues, contact Accu-Chek customer support.

Specifikationer

FeatureDetalje
ModelnummerROC048310
Produktdimensioner6.6 x 3.9 x 5.55 tommer
Varens vægt0.5 pund
Batteritype1 Product Specific battery (Lithium, included)
Sample Størrelse0.6 µL
Test tidCirka 5 sekunder
ViseBrilliant backlit display
KodningNo coding required
stikkeanordningAccu-Chek FastClix with 11 depth settings

Garanti og support

Garantioplysninger

Accu-Chek Nano SmartView Blood Glucose Monitoring System typically comes with a 3-year limited warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

Kundesupport

For technical assistance, troubleshooting, or warranty service, please contact Accu-Chek customer support. The customer service number can usually be found on the back plate of your meter or in the packaging materials. Have your meter's serial number ready when you call.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.