CEM DT-8806H

CEM DT-8806H Contactless Infrared Thermometer User Manual

Model: DT-8806H | Brand: CEM

1. Produktet er slutview

The CEM DT-8806H is a precise, non-contact infrared thermometer designed for quick and accurate temperature measurements. It is suitable for both body temperature screening and measuring the temperature of objects and surfaces. This device incorporates advanced technology and a sensitive sensor to ensure reliable readings.

CEM DT-8806H Contactless Infrared Thermometer, front view

Figur 1: Forside view of the CEM DT-8806H Contactless Infrared Thermometer, showing the display and measurement button.

Nøglefunktioner:

  • Clinical and Hospital Quality: Certified according to ISO 13485, CE, FCC, ROHS, and FDA, complying with EN 60601-1.2006+ A12:2014, EN 60601-1-2:2015.
  • Høj nøjagtighed: Provides accurate measurements within 0.2 °C (for 36-39 °C range) in 0.5 seconds.
  • Contactless Measurement: Operates at a distance of 5-15 cm, ensuring hygienic use.
  • Digital LCD-skærm: Clear display for easy reading, even in low light conditions.
  • Energibesparelse: Features automatic power-off after 7 seconds of inactivity.
  • Multifunktionel: Capable of measuring body, ear, forehead, ambient, object, food, and liquid temperatures.
  • Hukommelsesfunktion: Stores up to 32 measurement data points for temperature history tracking.

2. Opsætning

2.1. Batteriinstallation

The CEM DT-8806H thermometer requires batteries for operation. A battery is included with the product.

  1. Find batteridækslet på termometerets håndtag.
  2. Skub eller åbn dækslet i henhold til indikatoren.
  3. Insert the batteries, ensuring correct polarity (+ and -) as indicated inside the compartment.
  4. Luk batterirummets dæksel forsvarligt.

Note: Always use the specified battery type and dispose of old batteries responsibly.

2.2. Første opstart

After installing the batteries, the thermometer is ready for use.

  1. Press the measurement trigger button to power on the device.
  2. The LCD display will illuminate and show the last measurement or enter standby mode.

3. Betjeningsvejledning

The DT-8806H offers two primary measurement modes: Body mode and Surface mode.

CEM DT-8806H Contactless Infrared Thermometer, side view with mode switch

Figur 2: Side view of the thermometer, highlighting the mode switch for Body and Surface measurements.

3.1. Skift af måletilstande

To switch between Body and Surface measurement modes, locate the mode switch on the side of the thermometer.

  • Skub kontakten til "Body" position for human body temperature measurements.
  • Skub kontakten til "Surface" position for measuring the temperature of objects, liquids, or ambient air.

3.2. Measuring Body Temperature (Body Mode)

  1. Ensure the thermometer is in "Body" mode.
  2. Point the thermometer at the center of the forehead, maintaining a distance of 5-15 cm (2-6 inches).
  3. Press the measurement trigger button.
  4. The temperature reading will be displayed on the LCD screen within 0.5 seconds.
  5. Termometeret gemmer automatisk aflæsningen i sin hukommelse.

Vigtig: For consistent readings, ensure the measurement distance is maintained. If a person has just entered from outdoors, wait approximately 10 minutes for their body temperature to stabilize before measuring.

3.3. Measuring Object/Surface Temperature (Surface Mode)

  1. Ensure the thermometer is in "Surface" mode.
  2. Point the thermometer at the object or surface you wish to measure.
  3. Press the measurement trigger button.
  4. Temperaturaflæsningen vil blive vist på LCD-skærmen.

This mode is suitable for measuring temperatures of milk, bath water, room air, food, and other non-living objects.

3.4. Hukommelsesfunktion

The thermometer automatically stores the last 32 temperature measurements. To recall past readings, refer to the device's specific button functions (usually a "MEM" or "LOG" button, though not explicitly detailed in input, common for such devices).

4. Vedligeholdelse

4.1. Rengøring af termometeret

To ensure accurate readings and hygienic use, regularly clean your thermometer.

  • Tør termometerets krop af med en blød kludamp klæde.
  • For the sensor lens, use a cotton swab lightly moistened with alcohol. Clean gently to avoid scratching.
  • Nedsænk ikke termometeret i vand eller anden væske.
  • Brug ikke slibende rengøringsmidler eller opløsningsmidler.

4.2. Opbevaring

Store the thermometer in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity. Keep it out of reach of children.

5. Fejlfinding

This section addresses common issues you might encounter with your CEM DT-8806H thermometer.

5.1. Inconsistent Measurements

Problem: Measurements are always different when taken in quick succession.

Mulige årsager og løsninger:

  • Natural Skin Temperature Changes: Human skin temperature can fluctuate.
  • Measurement Distance Variation: Ensure a consistent distance of 5-15 cm from the forehead.
  • Air Temperature Changes: Significant changes in ambient air temperature can affect readings.
  • Environmental Acclimatization: If a person has just come indoors from a different temperature environment, wait approximately 10 minutes for their body temperature to stabilize before measuring.
  • Alternative Measurement Sites: For comparison or if forehead readings are consistently problematic, try measuring behind the ear, in the mouth, or under the armpit with a standard clinical thermometer (if applicable for comparison, though this is a non-contact device).

5.2. Incorrect Temperature Readings (e.g., always 95°F / 35°C)

Problem: The thermometer consistently displays an incorrect or fixed temperature, such as 95°F (35°C).

Possible Cause & Solution:

  • Incorrect Measurement Mode: Ensure the thermometer is set to the correct mode for your intended measurement.
    • For human body temperature, the mode switch must be set to "Body".
    • For object or liquid temperatures (e.g., milk, bath water), the mode switch must be set to "Surface".

6. Specifikationer

SpecifikationVærdi
MærkeCEM
ModelnummerDT-8806H
MåletypeKontaktløs infrarød
Måleafstand5-15 cm
Målingstid0.5 sekunder
Accuracy (Body Mode)±0.2 °C (within 36-39 °C)
Display TypeDigital LCD
Hukommelseslagring32 målinger
StrømkildeBatteridrevet
Automatisk sluk7 seconds (without operation)
CertificeringerISO 13485, CE, FCC, ROHS, FDA, EN 60601-1.2006+ A12:2014, EN 60601-1-2:2015
Varens vægt310 g
MaterialePlast

7. Garanti og support

7.1. Garantioplysninger

Please refer to the warranty card included with your product packaging for detailed warranty terms and conditions. Typically, CEM products come with a manufacturer's warranty covering defects in materials and workmanship from the date of purchase.

7.2. Kundesupport

For technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact CEM customer support. Contact information can usually be found on the product packaging, the official CEM webwebstedet eller forhandlerens supportside.

Note: Always provide your product model number (DT-8806H) and purchase details when contacting support.

© 2024 CEM. All rights reserved.

Denne manual er kun til orientering. Specifikationerne kan ændres uden varsel.