Sicce 925607

Sicce Ultrazero Flat Sucking Pump Instruction Manual

Model: 925607

1. Produktet er slutview

The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.

Nøglefunktioner:

  • Capable of pumping water down to 2 mm residual level.
  • Fully submersible design.
  • Handles dirt particles up to 3 mm in size.
  • Equipped with a 10-meter power cable.
  • Features a practical carry handle for easy transport.
Sicce Ultrazero Flat Sucking Pump

Figur 1: Overview of the Sicce Ultrazero Flat Sucking Pump.

2. Sikkerhedsoplysninger

Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Frakobl altid pumpen fra strømforsyningen før håndtering, rengøring eller udførelse af vedligeholdelse.
  • Sørg for, at strømforsyningen voltage matches the pump's specifications (230 V/50 Hz).
  • Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
  • Do not use the pump to handle flammable or explosive liquids.
  • Hold børn og uautoriserede personer væk fra driftsområdet.
  • Sørg for, at pumpen er helt nedsænket under drift for at forhindre overophedning.
  • Avoid running the pump dry for extended periods.
  • This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.

3. Opsætning og installation

Follow these steps to properly set up your Ultrazero pump:

  1. Pak pumpen ud: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
  2. Connect the Discharge Hose:

    The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

    Pump outlet and handle

    Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.

  3. Placer pumpen: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
  4. Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
  5. Strømtilslutning: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.
Pumpe bund

Figure 3: The flat base of the pump designed for low residual water levels.

4. Betjeningsvejledning

The Ultrazero pump is designed for simple operation:

  1. Nedsænk pumpen: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
  2. Begynd at pumpe: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
  3. Overvåg vandstanden: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
  4. Stop pumpning: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.
Pump draining a small pool

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Pump draining a flooded floor

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Pump showing 2mm residual water level

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.

5. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer pumpens levetid og optimale ydeevne.

  • Rensning: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
  • Undersøg for affald: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
  • Kabelinspektion: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
  • Opbevaring: When not in use, store the pump in a clean, dry place, protected from frost.
Pump used for garden watering

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.

6. Fejlfinding

If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Pumpen starter ikke.Ingen strømforsyning.
Strømkabel beskadiget.
Motorens overbelastningsbeskyttelse aktiveret.
Kontroller strømtilslutning og stikkontakt.
Inspect cable for damage; replace if necessary (by qualified personnel).
Disconnect power, allow motor to cool, then reconnect.
Pumpen kører, men der kommer ikke vand ud.Intake blocked.
Udløbsslangen er bøjet eller blokeret.
Airlock in pump.
Disconnect power, clear intake.
Check and clear discharge hose.
Briefly lift and lower the pump while submerged to release trapped air.
Reduced pumping performance.Partial blockage.
Impeller worn.
Disconnect power, clean pump intake and impeller area.
Kontakt kundesupport for service.
Pumpen stopper uventet.Overheating due to low water level or blockage.
Elektrisk fejl.
Disconnect power, check water level and clear blockages. Allow to cool.
Hvis problemet fortsætter, skal du kontakte kundesupport.

If the problem persists after attempting these solutions, please contact Sicce customer support.

7. Tekniske specifikationer

Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:

SpecifikationVærdi
MærkeSicce
Modelnummer925607
Max. Delivery Rate (Flow Rate)3000 l/t
Maks. Leveringshøjde3.1 m
Power Consumption (P1)80 W
Operation Voltage220-240 V / 50 Hz
Conductor Length (Power Cable)10 m (three-core, indoor and outdoor use)
Trykforbindelse26.44 mm (3/4") AG
Slangetilslutningsdiameter20 mm (3/4")
Max. Solids Size3 mm
RestvandstandDown to 2-3 mm
Produktmål (ca.)140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3"
Varens vægt2.6 kg (5.72 lbs)
Float switchIngen
OverbelastningsbeskyttelseNo (Internal thermal protection may exist, but no external reset)
OprindelseFremstillet i Italien
Technical drawing with pump dimensions

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.

8. Garanti og support

For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.

Fabrikant: Ebara

Mærke: Sicce

For further assistance, visit the official Sicce webwebstedet eller kontakt din lokale forhandler.

© 2026 Sicce. All rights reserved. This manual is for informational purposes only.