PILZ 777314

Pilz PNOZ X3P Safety Relay Instruction Manual

Model: 777314 | Brand: PILZ

1. Introduktion

This manual provides essential information for the safe installation, operation, and maintenance of the Pilz PNOZ X3P Safety Relay, model 777314. The PNOZ X3P is designed for monitoring E-STOP pushbuttons, safety gates, and light grids in industrial applications, ensuring personnel and machine safety.

2. Sikkerhedsinstruktioner

ADVARSEL: Failure to follow these safety instructions can result in serious injury or death, and damage to equipment.

  • Only qualified personnel familiar with industrial safety standards and electrical systems should install, operate, or maintain this device.
  • Disconnect all power before performing any installation, wiring, or maintenance tasks.
  • Sørg for, at al ledningsføring overholder lokale og nationale elektriske forskrifter.
  • Sikkerhedsfunktioner må ikke omgås eller deaktiveres.
  • Regularly inspect the device and associated safety components for damage or malfunction.
  • Use only genuine PILZ replacement parts.

3. Produktet er slutview

The Pilz PNOZ X3P (Model 777314) is a safety relay designed for monitoring safety functions. It features:

  • Fungere: E-STOP, safety gate, light grid monitoring.
  • Kontaktkonfiguration: 3 Normally Open (NO) safety contacts, 1 Normally Closed (NC) auxiliary contact, 1 Semiconductor Output (SO).
  • Forsyning Voltage Område: 24-240VAC/DC (Coil Voltage: 24V AC/DC).
  • Driftstilstand: Automatisk nulstilling.
  • Bredde: 45 mm.
Pilz PNOZ X3P Safety Relay, front view med terminaler og indikatorer

Figur 1: Forside view of the Pilz PNOZ X3P Safety Relay, showing terminals and indicators.

4. Opsætning og installation

4.1 Montering

Mount the PNOZ X3P on a 35mm DIN rail in a control cabinet. Ensure adequate ventilation around the device to prevent overheating. Maintain proper clearance from heat-generating components.

4.2 Elektriske forbindelser

Before making any electrical connections, ensure the main power supply is disconnected and locked out. Refer to the wiring diagrams for correct terminal assignments.

5. Ledninger

The PNOZ X3P supports 1-channel or 2-channel wiring for safety inputs. The choice depends on the required safety integrity level (SIL) and performance level (PL).

5.1 Input Wiring (E-STOP, Safety Gate, Light Grid)

  • 1-Channel Wiring: Connect the safety device (e.g., E-STOP) to a single input channel. This configuration offers basic safety.
  • 2-Channel Wiring: Connect the safety device to two independent input channels. This configuration provides redundancy and higher fault tolerance, suitable for higher safety requirements.

5.2 Output Wiring

The relay provides 3 NO safety contacts for controlling power to hazardous machinery and 1 NC auxiliary contact for signaling purposes. The 1 SO (semiconductor output) can be used for diagnostic feedback to a PLC.

Ensure that the load connected to the safety contacts does not exceed the maximum switching current of 15 Amps and maximum switching voltage på 240 volt.

Figur 2: Eksample wiring diagram for a 2-channel E-STOP application. (Actual diagram not provided, refer to product documentation for specific wiring.)

6. Betjeningsvejledning

The PNOZ X3P operates in an automatic reset mode. Once the safety input circuit is closed (e.g., E-STOP released, safety gate closed), the safety relay will automatically energize its output contacts, provided no faults are detected.

6.1 Opstart

Upon applying power, the relay performs an internal self-test. If the safety inputs are closed and no faults are present, the output contacts will close, and the status indicators will illuminate.

6.2 Aktivering af sikkerhedsfunktion

When a safety input is opened (e.g., E-STOP pressed, safety gate opened), the PNOZ X3P immediately de-energizes its safety output contacts, bringing the monitored machine to a safe state.

6.3 Nulstilling

Due to its automatic reset function, the relay will re-energize its outputs as soon as the safety input circuit is restored and no faults are present. Ensure that the machine can only restart safely after a reset.

7. Vedligeholdelse

Regular maintenance is crucial to ensure the continued safe operation of the PNOZ X3P safety relay.

  • Periodisk eftersyn: Visually inspect the device and its wiring for any signs of damage, loose connections, or contamination.
  • Funktionstest: Periodically test the entire safety circuit, including the PNOZ X3P, by activating the connected safety devices (E-STOP, safety gate, light grid) to verify their proper function.
  • Rensning: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.

8. Fejlfinding

If the safety relay does not function as expected, consider the following common issues:

ProblemMulig årsagLøsning
Outputs do not energize after power-up.
  • Ingen strømforsyning.
  • Safety inputs open (e.g., E-STOP pressed).
  • Intern fejl.
  • Kontroller strømtilslutninger og volumentage.
  • Ensure all safety inputs are closed.
  • Contact PILZ technical support.
Outputs de-energize unexpectedly.
  • Safety input opened momentarily.
  • Løse ledninger.
  • Interferens.
  • Check safety devices for intermittent operation.
  • Undersøg alle ledningsforbindelser.
  • Ensure proper grounding and shielding.

If troubleshooting steps do not resolve the issue, contact PILZ technical support.

9. Tekniske specifikationer

ParameterVærdi
Model777314
MærkeMUSHROOM
DriftstilstandAutomatisk
Coil Voltage24 volt (AC/DC)
Kontakt Nuværende vurdering6 Amps
Maksimal skiftestrøm15 Amps
Maksimal switching voltage240 volt
Varens vægt0.64 pund

10. Garanti og support

PILZ products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the official PILZ webwebstedet eller kontakt din lokale forhandler.

For technical assistance, product support, or to report a malfunction, please contact PILZ customer service. Have your product model (777314) and serial number ready when contacting support.

PILZ Officiel Webwebsted: www.pilz.com

© 2024 PILZ. Alle rettigheder forbeholdes. Oplysninger kan ændres uden varsel.

Relaterede dokumenter - 777314

Preview Pilz PNOZ X7 sikkerhedsrelæ betjeningsvejledning
Omfattende betjeningsvejledning til Pilz PNOZ X7 sikkerhedsrelæet, der beskriver dets funktioner, installation, betjening, sikkerhedsspecifikationer og tekniske data til industrielle automatiseringsapplikationer.
Preview Pilz PNOZ 3 Emergency Stop Relay and Safety Gate Monitor Technical Manual
Technical specifications, wiring diagrams, and operating instructions for the Pilz PNOZ 3 Emergency Stop Relay and Safety Gate Monitor.
Preview Pilz PNOZ 2VQ E-STOP Relay and Safety Gate Monitor Datasheet
Technical datasheet for the Pilz PNOZ 2VQ safety relay, designed for monitoring E-STOP pushbuttons and safety gates. Includes specifications, wiring diagrams, and installation instructions.
Preview Pilz PNOZ 1 Emergency Stop Relay and Safety Gate Monitor Datasheet
Technical specifications, wiring diagrams, and operating modes for the Pilz PNOZ 1 Emergency Stop Relay and Safety Gate Monitor. Category 3, EN 954-1 compliant.
Preview Pilz PNOZ X6 sikkerhedsrelæ betjeningsvejledning
Omfattende betjeningsvejledning til Pilz PNOZ X6 sikkerhedsrelæ, der dækker funktion, installation, ledningsføring, betjening og tekniske specifikationer. Indeholder sikkerhedsretningslinjer og bestillingsoplysninger.
Preview Pilz PNOZ s4 sikkerhedsrelæ - brugermanual og tekniske detaljer
Omfattende guide til Pilz PNOZ s4 sikkerhedsrelæ, der dækker dets funktioner, installation, ledningsføring, betjening og tekniske specifikationer for at sikre maskinsikkerhed.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.