1. Vigtige sikkerhedsinstruktioner
Please read these instructions carefully before installation and use. Failure to follow these instructions may result in property damage, personal injury, or death.
- This appliance must be installed by a qualified electrician and plumber in accordance with all local and national regulations.
- Ensure the electrical supply matches the specifications of the appliance (230 V, 3.5 kW).
- Do not operate the appliance if it is damaged or not functioning correctly.
- Do not block the water outlet or tamper med overtryksventilen.
- This unit is designed for pressureless operation. Only use the special mixer tap supplied with the unit.
- Hold børn væk fra apparatet under drift.
- Afbryd strømforsyningen, før der udføres vedligeholdelse eller rengøring.
2. Produktet er slutview
The CLAGE M3/SMB is a compact, hydraulically controlled small instantaneous water heater designed for over-sink installation. It provides hot water instantly for a single tap, making it ideal for hand washing or small dishwashing tasks. The unit features an effective bare-wire heating system (IES®) and comes with a special mixer tap for wall connection.

This image displays the CLAGE M3/SMB small instantaneous water heater unit mounted above a chrome-finished mixer tap. The water heater unit is a compact, rectangular, silver-colored device designed for over-sink installation. The mixer tap features two control knobs and a curved spout.
3. Tekniske specifikationer
| Specifikation | Værdi |
|---|---|
| Modelnummer | M3/SMB |
| Strømudgang | 3.5 kW |
| Nominel bindtage | 230 V |
| Elektrisk tilslutning | 1 AC/N/PE, Plug-ready |
| Dimensioner (H x B x D) | 135 x 186 x 87 mm |
| Vægt | Ca. 1.92 kg |
| Beskyttelsesklasse | IP 25 |
| Vandtilslutninger | 3/8 tomme |
| Driftstryk | Pressureless |
| Monteringstype | Wall-mounted, Over-sink |
4. Installation (Opsætning)
Installation skal udføres af en kvalificeret fagmand.
4.1 Udpakning
- Fjern forsigtigt alle komponenter fra emballagen.
- Check for any visible damage. Do not install if damaged.
- Ensure all parts listed in the packing contents are present.
4.2 Montering af enheden
- Select a suitable wall location directly above the sink, ensuring sufficient space for maintenance and operation.
- Use the variable metal wall bracket to mark drilling points.
- Bor huller og isæt passende vægdyvler.
- Securely fasten the wall bracket to the wall.
- Mount the water heater unit onto the bracket.
4.3 Vandtilslutning
- Connect the cold water supply to the designated inlet on the mixer tap (usually marked blue).
- Connect the hot water outlet from the unit to the designated inlet on the mixer tap (usually marked red).
- Ensure all connections are tight to prevent leaks. Use appropriate sealing materials.
- Open the main water supply and check for leaks.
- Before electrical connection, flush the unit by opening the tap until water flows freely and air is expelled.
4.4 Elektrisk tilslutning
- Sørg for, at hovedstrømforsyningen er afbrudt ved afbryderen.
- Connect the appliance to a dedicated 230 V, 3.5 kW electrical circuit. The unit is plug-ready.
- Kontroller korrekt jordforbindelse.
- Once connections are secure, switch on the main power supply.
5. Betjening
5.1 Første brug
- After installation and electrical connection, ensure the unit is completely filled with water by opening the cold water tap until water flows steadily.
- Turn the hot water knob on the mixer tap. The heating element will activate, and hot water will begin to flow after a short delay.
- Adjust the water temperature by mixing hot and cold water using the mixer tap controls.
5.2 Daglig brug
- To obtain hot water, turn the hot water knob on the mixer tap. The unit will heat water as it flows through.
- To obtain cold water, turn the cold water knob.
- Adjust the flow rate and temperature as desired using the tap controls.
- The unit is designed for continuous flow within its specified capacity.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your CLAGE M3/SMB water heater.
- Rengøring af ydersiden: Rengør ydersiden af enheden med en blød, damp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Afkalkning: Depending on water hardness, limescale can build up in the heating system. If you notice a decrease in hot water flow or temperature, the unit may need descaling. This procedure should be performed by a qualified technician.
- Kontrol af forbindelser: Periodically inspect water and electrical connections for any signs of leaks or wear.
- Mixer Tap Maintenance: Clean the aerator of the mixer tap regularly to remove any debris or limescale buildup that might restrict water flow.
7. Fejlfinding
Før du kontakter kundesupport, bedes du læse følgende fejlfindingsvejledning:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Intet varmt vand | Ingen strømforsyning Water flow too low Fejl på varmelegeme | Check circuit breaker and power connection Increase water flow at the tap Kontakt en kvalificeret tekniker |
| Lav varmtvandsgennemstrømning | Tilstoppet perlator Kalkopbygning Utilstrækkeligt vandtryk | Rengør belufteren Descale unit (professional service) Check main water supply pressure |
| Water leaking from unit or connections | Løse forbindelser Beskadigede tætninger Intern fejl | Tighten connections (do not overtighten) Replace seals (professional service) Kontakt en kvalificeret tekniker |
| Vand ikke varmt nok | Vandstrømmen er for høj Kalkopbygning | Reduce water flow at the tap Descale unit (professional service) |
If the problem persists after attempting these solutions, please contact a qualified technician or CLAGE customer support.
8. Garanti og support
For warranty information, technical support, or spare parts, please refer to the official CLAGE website or contact your local CLAGE dealer. Keep your purchase receipt as proof of purchase.