This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Eltako KR09-230V Switching Relay. Please read this manual thoroughly before using the device and retain it for future reference.

The Eltako KR09-230V is a compact switching relay designed for various electrical control applications. It features a rated voltage of 230V AC and can handle a maximum current of 6 A.

2. Sikkerhedsoplysninger

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified electricians in accordance with national and local electrical codes.

  • Afbryd altid strømmen før installation, service eller afmontering af relæet.
  • Sørg for korrekt jordforbindelse og ledningsforbindelser.
  • Overskrid ikke den angivne voltage og aktuelle klassificeringer af enheden.
  • Beskyt enheden mod fugt, støv og ekstreme temperaturer.
  • Never operate the device if it appears damaged.

3. Produktet er slutview

The Eltako KR09-230V is a single-pole switching relay designed for reliable control in electrical systems. It is typically mounted on a DIN rail for easy integration into control cabinets.

Eltako KR09-230V Switching Relay front view

Figur 1: Forside view of the Eltako KR09-230V Switching Relay, showing terminals A1, A2, 1, and 2, along with the Eltako logo and model designation KR09.

Eltako KR09-230V Switching Relay side view med terminaldetaljer

Figur 2: Side view of the Eltako KR09-230V Switching Relay, illustrating the compact design and screw terminals for electrical connections.

Nøglefunktioner:

  • Kompakt design til DIN-skinnemontering.
  • Normally open (NO) contact type.
  • Silver contact material for durability.
  • Clear terminal markings for easy wiring.

4. Specifikationer

FabrikantEltako
Model-/artikelnummerKR09-230V / 1393104
Nominel voltage230V AC
Maks. strømstyrke6 Ampere
Wattage500 watt
KontakttypeNormalt åben (NEJ)
KontaktmaterialeSølv
MonteringstypeDIN -skinne montering
Dimensioner (L x B x H)10 x 5 x 1 cm
Vægt40 g
TilslutningstypeSkrueterminaler

5. Installation og opsætning

The Eltako KR09-230V Switching Relay is designed for DIN rail mounting within an electrical enclosure or control panel. Ensure that the installation environment is dry and free from excessive vibrations.

  1. Strømafbrydelse: Before beginning any installation, ensure that the main power supply to the circuit is completely disconnected and locked out to prevent accidental re-energization.
  2. Montering: Snap the relay onto a standard 35mm DIN rail. Ensure it is securely fastened.
  3. Ledningsføring: Tilslut kontrolvolumentage (230V AC) to terminals A1 og A2. The relay's internal coil will be energized by this voltage.
  4. Belastningsforbindelse: Connect the circuit to be switched to terminals 1 og 2. These are the normally open (NO) contacts. When the control voltage is applied to A1/A2, the contacts between 1 and 2 will close, allowing current to flow through the connected load.
  5. Verifikation: Double-check all wiring connections for correctness and tightness. Ensure no bare wires are exposed.
  6. Strømgendannelse: Når alle forbindelser er verificeret, skal strømmen til kredsløbet genoprettes.

Se lokale elektriske forskrifter og standarder for specifikke krav til ledningsføring.

6. Betjening

The Eltako KR09-230V functions as a simple switching relay:

  • When 230V AC control voltage is applied to terminals A1 og A2, the relay coil energizes.
  • Upon energization, the normally open contacts between terminals 1 og 2 close. This completes the circuit for the connected load, allowing power to flow.
  • When the 230V AC control voltage er fjernet fra A1 og A2, the relay coil de-energizes.
  • The contacts between 1 og 2 then return to their normally open state, breaking the circuit and turning off the connected load.

This relay is suitable for applications requiring remote switching of loads, signal isolation, or simple control logic within electrical systems.

7. Vedligeholdelse

The Eltako KR09-230V Switching Relay is designed to be maintenance-free under normal operating conditions. Regular inspection of the terminals for tightness and signs of overheating is recommended as part of routine electrical system checks.

If the device shows signs of damage or malfunction, it should be replaced by a qualified professional.

8. Fejlfinding

If the relay is not functioning as expected, consider the following common issues:

  • Relay does not switch:
    • Check if the 230V AC control voltage is correctly applied to terminals A1 and A2.
    • Verify that the control voltage er inden for det angivne område.
    • Undersøg ledningerne for løse forbindelser eller brud.
  • Load does not receive power when relay switches:
    • Ensure the load circuit is correctly wired to terminals 1 and 2.
    • Check the load itself for faults.
    • Verify that the load current does not exceed the relay's 6A rating. Overcurrent can damage the contacts.
  • Overophedning:
    • Ensure the load current is not exceeding the maximum rating.
    • Check for loose terminal connections, which can cause resistance and heat.
    • Ensure adequate ventilation around the relay.

For persistent issues, consult a qualified electrician or contact Eltako customer support.

9. Garanti og support

Eltako products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the official Eltako webwebstedet eller kontakt din lokale forhandler.

For technical support or inquiries, please visit the official Eltako website or contact their customer service department. When contacting support, please have your product model (KR09-230V) and article number (1393104) available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.