This manual provides detailed instructions for the installation, operation, and maintenance of the White-Rodgers Fan Control Center, Model 90-118E. This device is designed to manage fan operations in heating, ventilation, and air conditioning (HVAC) systems. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
Sikkerhedsoplysninger
ADVARSEL: Risiko for elektrisk stød. Afbryd strømmen før installation eller service.
- Installation must be performed by a qualified technician in accordance with all local and national electrical codes.
- Ensure the power supply to the HVAC system is completely disconnected before beginning any work.
- Verify all wiring connections are secure and correct to prevent damage to the unit or system.
- Betjen ikke enheden, hvis en del er beskadiget.
Produkt overview
The White-Rodgers Fan Control Center 90-118E is a robust component designed for reliable fan control. Key features include:
- Plug-in style relay: Facilitates easy field replacement.
- Pre-stripped, color-coded leads: Forenkler ledningsforbindelser.
- Five combination screw/solder terminals: For lav voltage ledninger.
- Standard double-throw relays: Capable of handling both one and two-speed motors.
- Mounting design: Suitable for a 4-inch electrical box.

Figur 1: White-Rodgers Fan Control Center 90-118E. This image shows the control center from an angled perspective, highlighting the metal mounting plate, the central transformer component, and the pre-stripped, color-coded wires neatly bundled and connected to the terminal block.
Installation
Nødvendige værktøjer:
- Skruetrækker (Phillips og/eller flad)
- Trådstrippere/skærere
- Multimeter (for verification)
Installationstrin:
- Afbryd strømmen: Turn off the main power supply to the HVAC system at the circuit breaker. Verify power is off using a multimeter.
- Remove Existing Unit (if applicable): Carefully disconnect and remove the old fan control center, noting all wiring connections.
- Mount the New Unit: The 90-118E is designed for mounting in a standard 4-inch electrical box. Secure the unit using appropriate screws.
- Ledningsforbindelser: Connect the pre-stripped, color-coded leads to the corresponding terminals in your HVAC system. Refer to your specific HVAC system's wiring diagram for accurate connections. The unit features five combination screw/solder terminals for low voltage ledninger.
- Relay Installation: The plug-in style relay should be securely seated in its receptacle.
- Bekræft forbindelser: Dobbelttjek alle ledningsforbindelser for tæthed og korrekthed.
- Gendan strøm: Once all connections are verified, restore power to the HVAC system.
Operation
The White-Rodgers Fan Control Center 90-118E operates automatically as an integral part of your HVAC system. It receives signals from the thermostat or other control devices to activate and deactivate the fan motor. Its primary function is to provide reliable switching for fan operations, supporting both single and two-speed motors.
- Upon receiving a call for fan operation (e.g., from a thermostat), the internal relay will energize, closing the appropriate contacts to power the fan motor.
- When the call for fan operation ceases, the relay de-energizes, opening the contacts and turning off the fan motor.
- The double-throw relay design allows for flexible control of different fan motor types and speeds, depending on the system's configuration.
Opretholdelse
The White-Rodgers Fan Control Center 90-118E is designed for minimal maintenance. Regular inspection by a qualified technician is recommended as part of routine HVAC system checks.
- Årlig inspektion: During annual HVAC system servicing, have a technician inspect the control center for any signs of wear, corrosion, or loose connections.
- Rensning: Ensure the unit is free from dust and debris. Use a soft, dry brush or compressed air for cleaning. Do not use liquid cleaners.
- Udskiftning af relæ: The plug-in style relay is designed for easy replacement if it fails. Ensure power is disconnected before attempting to replace the relay.
Fejlfinding
If you experience issues with your fan control center, refer to the following common troubleshooting steps. For complex issues, contact a qualified HVAC technician.
- Ventilator tænder ikke:
- Check if the main power supply to the HVAC system is on.
- Verify the thermostat is calling for fan operation.
- Undersøg ledningsforbindelserne for løse eller beskadigede.
- Test the relay for continuity (requires a multimeter and electrical knowledge).
- Fan Running Continuously:
- Check if the thermostat is stuck in the "Fan ON" position.
- The relay contacts may be fused closed. The relay may need replacement.
- Intermittent Fan Operation:
- Løse ledningsforbindelser.
- Faulty relay or control board in the HVAC system.
- No Low Voltage (24V) Output:
- Check the primary 120V input to the control center.
- The internal transformer may be faulty.
Specifikationer
| Feature | Specifikation |
|---|---|
| Modelnummer | 90-118E |
| Primary VAC | 120V |
| Secondary VAC | 24V |
| Connector Type | Plug-in |
| Kontakttype | Normally Open (SPNO/SPNC) |
| Monteringstype | Plug In Mount (for 4-inch box) |
| Driftstilstand | Automatisk |
| Coil Voltage | 24 volt |
| Maksimal switching voltage | 24 volt |
| Produktdimensioner | 1 x 1 x 1 tommer (ca.) |
| Varens vægt | 1.98 pund (omtrentligt) |
| Fabrikant | Hvide Rodgers |
| Fremstillingsland | USA |
Garanti og support
For warranty information and technical support, please refer to the official White-Rodgers webwebstedet eller kontakt deres kundeservice. Gem din købskvittering til garantikrav.
White-Rodgers Customer Service: Visit Emerson.com/contact-us (White-Rodgers is an Emerson brand)