Socket Mobile SL0707-078

Socket Mobile SL0707-078 Ruggedized Serial I/O PC Card User Manual

Model: SL0707-078

1. Introduktion

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Socket Mobile SL0707-078 Ruggedized Serial I/O PC Card. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

2. Produktet er slutview

The Socket Mobile SL0707-078 is a Ruggedized Serial I/O PC Card designed to add a high-speed RS-232 port to your mobile computer. It enables connectivity with a wide range of serial devices, including fax/modems, digital cameras, bar code scanners, monitoring and control systems, data collection gear, lab equipment, and GPS receivers. The card features a robust design with a 17-inch cable terminating in a male DB-9 connector.

Socket Mobile SL0707-078 Ruggedized Serial I/O PC Card

Figure 1: Socket Mobile SL0707-078 Ruggedized Serial I/O PC Card with attached DB-9 cable.

3. Nøglefunktioner

  • Højhastighedsforbindelse: Supports baud rates up to 921.6 Kbps with Hi-Speed COM Tools.
  • COM Port Management: Allows quick identification and modification of COM port assignments.
  • Standard interface: Equipped with one RS-232 serial port and an industry-standard DB-9 Connector.
  • UART Compatibility: Provides standard 16550 compatible UARTS, with compatibility for 16650, 16750, and 16950.
  • Enhanced FIFO: Includes UARTS with 128-byte FIFO for improved data handling.
  • Hardware flow kontrol: Supports hardware flow control for reliable data transmission.
  • Lavt strømforbrug: Utilizes only 2.4mA (typical at 3.3V), extending mobile computer battery life.
  • Plug & Play: Features Plug & Play and hot-swapping capabilities.
  • Voltage Kompatibilitet: Operates in both 3.3V and 5V systems.
  • Robust design: Durable construction suitable for various environments.

4. Systemkrav

To use the Socket Mobile SL0707-078 PC Card, your mobile computer must meet the following requirements:

  • Operativsystem:
    • Windows 95 (v4.00.950B)
    • Windows 98 / 98 Second Edition
    • Windows Me
    • Windows 2000
    • Windows XP
    • Windows CE for Pocket PC 2000/2002/2003
    • Windows CE for HPC Pro 2.11 / HPC 2000
  • Available PC Card Slot: A compatible PC Card (PCMCIA) slot.

5. Opsætning og installation

Follow these steps to install your Socket Mobile SL0707-078 PC Card:

  1. Insert the PC Card: Carefully insert the Socket Mobile SL0707-078 PC Card into an available PC Card slot on your mobile computer. Ensure it is fully seated.
  2. Driver installation:
    • Upon insertion, your operating system may automatically detect new hardware and prompt for driver installation.
    • Insert the driver CD (if provided) or download the latest drivers and Hi-Speed COM Tools from the Socket Mobile official webwebsted.
    • Følg instruktionerne på skærmen for at fuldføre driverinstallationen. Genstart computeren, hvis du bliver bedt om det.
  3. Tilslut seriel enhed: Connect your serial device (e.g., bar code scanner, GPS receiver) to the DB-9 connector on the ruggedized cable of the PC Card.
  4. Bekræft installationen:
    • Open your computer's Device Manager (e.g., in Windows, right-click "My Computer" or "This PC", select "Manage", then "Device Manager").
    • Expand the "Ports (COM & LPT)" section. You should see a new COM port listed for the Socket Mobile Serial I/O PC Card.
    • Note the assigned COM port number for use with your serial applications.

Important: Always install the correct drivers for your operating system to ensure proper functionality and optimal performance.

6. Betjeningsvejledning

Once the drivers are installed and the card is recognized, you can begin using the serial port:

  1. Accessing the COM Port: Your serial application (e.g., terminal emulator, data collection software) will require you to select the correct COM port number assigned to the Socket Mobile PC Card. Refer to your application's documentation for specific instructions.
  2. Configuring Baud Rates:
    • The Hi-Speed COM Tools allow you to map legacy baud rates to higher speeds (e.g., 230.4, 460.8, or 921.6 Kbps).
    • Launch the Hi-Speed COM Tools utility (usually found in your Start Menu or system tray).
    • Use the user-friendly visual display to set custom baud rates or re-map existing ones.
    • Ensure the baud rate setting in your application matches the setting configured for the COM port.
  3. Changing COM Port Assignments: If you need to change the assigned COM port number, use the Hi-Speed COM Tools or your operating system's Device Manager. This can be useful to avoid conflicts with other serial devices.
  4. Hot-swapping: The card supports hot-swapping. You can insert or remove the card while the computer is running, though it is generally recommended to close any applications actively using the serial port before removal.

7. Vedligeholdelse og pleje

To ensure the longevity and reliable operation of your Socket Mobile SL0707-078 PC Card, follow these guidelines:

  • Håndteres med forsigtighed: Avoid dropping the card or subjecting it to excessive force.
  • Hold rent: Periodically clean the card's contacts with a soft, dry, lint-free cloth. Do not use liquid cleaners.
  • Opbevaring: When not in use, store the card in a protective sleeve or case to prevent dust and physical damage.
  • Miljøforhold: Avoid exposing the card to extreme temperatures, humidity, or direct sunlight.
  • Kabelintegritet: Inspect the ruggedized cable and DB-9 connector regularly for any signs of wear or damage.

8. Fejlfinding

If you encounter issues with your Socket Mobile SL0707-078 PC Card, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Card not detected by computer.
  • Kortet er ikke sat helt i.
  • PC Card slot issue.
  • Drivere er ikke installeret.
  • Ensure the card is firmly seated in the PC Card slot.
  • Test with another PC Card slot or computer if possible.
  • Install the correct drivers from the Socket Mobile webwebsted.
Serial device not communicating.
  • Forkert COM-port valgt.
  • Baud rate mismatch.
  • Faulty serial cable or device.
  • Problem med driveren.
  • Verify the COM port number in Device Manager and your application.
  • Ensure baud rates in the Hi-Speed COM Tools and your application match.
  • Test with a different serial cable or device.
  • Geninstaller drivere.
Slow communication speeds.
  • Baud rate not optimized.
  • Software konfiguration.
  • Use the Hi-Speed COM Tools to map to higher baud rates (e.g., 921.6 Kbps).
  • Check your application's settings for optimal performance.

9. Tekniske specifikationer

ModelnummerSL0707-078
InterfacePC Card (PCMCIA)
Seriel porte1 x RS-232
StikDB-9 han
Max Baud Rate921.6 Kbps
UART Compatibility16550, 16650, 16750, 16950
FIFO størrelse128-byte
Strømforbrug2.4mA (typical at 3.3V)
Operation Voltage3.3V og 5V systemer
Produktdimensioner4 x 1 x 3 inches (approximate, card only)
Varens vægt2.08 ounce

10. Garantioplysninger

The Socket Mobile SL0707-078 Ruggedized Serial I/O PC Card comes with a Begrænset livstidsgaranti. This warranty covers defects in materials and workmanship under normal use. For detailed terms and conditions, including how to make a warranty claim, please refer to the official Socket Mobile webwebsted eller kontakt deres kundesupport.

11. Kundesupport

For technical assistance, driver downloads, or further information regarding your Socket Mobile SL0707-078 PC Card, please visit the official Socket Mobile webwebsted. Du kan typisk finde supportressourcer, ofte stillede spørgsmål og kontaktoplysninger til kundeservice der.

Note: For Sharp Zaurus support, refer to www.socketcom.com/ZaurusSharp.asp.

© 2024 Socket Mobile. All rights reserved.

Ask a question about this manual